2 user(s) found this FAQ helpful

Question:

Allplan does not react promptly or seems to hang after I have selected the "Open on a Project-Specific Basis" or "New Project, Open Project" tool.

One of the following virus scanners is running: Trendmicro, McAfee, Kaspersky, Avira, F-Prot and others.
What can I do to solve this problem?



Answer:

Check whether updating the software of the virus scanner solves the problem.

If it doesn't, configure the real time scanner of the virus scanner so that it no longer scans the program folder and data folder of Allplan.

Start the Services application. Make a note of the following paths displayed in the Services application window:

Program folder
General program data
Central file storage folder

Define these folders as exemptions in your virus scanner.


Bear in mind that virus scanners may be installed on the server and the clients (provided you work with a server).
For more information on the virus scanner, contact the manufacturer.

Download PDF  FAQ_EN_Real_time_scanner_blocks_Allplan_data.pdf ...
Version:  Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011  | Last modified: 20.09.2018
19 user(s) found this FAQ helpful

Question:

I just installed an upgrade. How can I convert all the projects at once?



Answer:

Back up all the projects beforehand!

Do the following:

  • Exit Allplan on all workstations.
  • Only when working with Workgroup Manager:
    Log in as the Allplan administrator (sysadm).
  • Start the Services application.
  • Only when working with Workgroup Manager:
    Make sure all the computers where projects are located are up and running.
    To check this, select:
    Services application -> Workgroup Manager -> Information -> Display Project List(the second column displays the computer where the project is located).
  • Go to the computer where you want to convert the data and set the drawing file size to the maximum value:
    Services application->Service ->Hotline Tools->docsize ->512 (or 1024, if available) ->OK
    Note:
    After data conversion, you can set the drawing file size back to the initial value.
  • Start converting the data (use the computer where you have changed the drawing file size):
    Services application ->Service ->Hotline Tools -> datwaprjs: convert data of all projects
    If you reply "Yes" at the following two prompts, the program will convert the data of all projects.



Notes:

The time it takes to convert the data depends on various factors:

  • Number of projects
  • Size of each project
  • Performance of the computer converting the data
  • Network performance


It is possible to start data conversion from several workstations at the same time.

Download PDF  FAQ_EN_Converting_all_Allplan_projects_in_a_single_o...
Version:  Allplan 2019  | Last modified: 12.11.2018
Not voted yet. Be the first to vote this FAQ as helpful!

Information:

This document provides further information on installing Allplan 2019.

Backing up and archiving data:

We strongly recommend that you back up and archive all your data before you upgrade to Allplan 2019.


How to install


You can find detailed instructions on how to install Allplan 2019 in the following places:

- After you have downloaded and unzipped Allplan 2019, you can find the ‘install.chm’ file in the following folder: C:\Users\Public\Documents\Allplan 2019\HelpFiles\English.

- Use the following link:
https://webdrive.allplan.com/s/4LrjrymoxESzC6p and open the General\Installation help\2019 folder.


Please read these instructions before you install Allplan 2019.

System requirements for Allplan 2019

https://connect.allplan.com/en/faqid/20180608093815.html

How to handle licenses when upgrading to Allplan 2019

https://connect.allplan.com/en/faqid/20180608092654.html



Some notes on installing Allplan 2019

If you want to switch from Allplan 2016/2017/2018 to Allplan 2019, you can choose between three installation options. We recommend using the second option: first-time installation and copy data from Allplan 2016/2017/2018.

1. First-time installation

This option installs Allplan 2019 to a new folder without affecting any other Allplan installation (2018 or earlier). Setup does not transfer any data or settings to the new installation.

If you want to transfer data later, you have the following options:

You can uninstall Allplan 2019 and then upgrade from Allplan 2016/2017/2018.
You can integrate the data manually (requires administrative knowledge).

2. First-time installation and copy data from version

This option installs Allplan 2019 to a new folder without affecting any other Allplan installation (2018 or earlier). You can configure Setup to automatically copy the office standard (\std), projects (\prj) and user data (\usr) from Allplan 2016/2017/2018 to the new installations folder.
This duplicates the data: You can use all projects, defaults and resources both in Allplan 2018 and in Allplan 2016/2017/2016. This way, you can test the new version without losing your 'old' Allplan version.
Bear in mind, though, that you should not mix data from different versions. Merging data later involves considerable time and effort.

2a. Continue with first-time installation and copy data from version

This option is available when you have already used the second installation option to install <Product_Version> to a computer that accesses the same data server. As a result, the data are already available.

3. Upgrade and transfer data from Allplan 2016/2017/2018

This option installs Allplan 2019 to an existing folder, converting Allplan 2016/2017/2018 to Allplan 2019 and transferring all important settings. Afterwards, you can no longer work with Allplan 2016/2017/2018.
This does nor affect earlier Allplan versions (Allplan 2015 or earlier).


Installing on a network:

  • If you work in a network environment (one common central file storage folder), you must upgrade all workstations to Allplan 2019. Beforeyou start installing, make sure that all workstations can be upgraded. For technical reasons, it is not possible to mix installations of different major releases. Any related problems area not covered by service contracts.
  • During the upgrade, Allplan 2016/2017/2018 must not be running on any workstation.
  • When installing with Workgroup Manager, make sure all workstations are checked in before you start upgrading.





Converting the data:

Data from earlier Allplan versions need to be converted to version 2019. Allplan 2019 automatically converts the data of a project you open. Click here for instructions on how to convert all projects in a single operation:

https://connect.allplan.com/en/faqid/20090408124904.html


IBD 2019

Click here for instructions on how to get your activation codes for Allplan IBD:

https://connect.allplan.com/en/faqid/20110912113530.html

Download PDF  FAQ_EN_Hotletter_2019.pdf
Version:  Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 08.05.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

After crashing, Allplan does not start anymore. When you open license selection in the license settings, you can see the following message: "Cannot find a license for running Allplan." How to solve this problem?



Answer:

Restart the service:

Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.

CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.



The crash causes this problem. The fact that the license is not available is a consequential error.

Note:

If Allplan crashes often,
send the following information by email to your Allplan Support:

  1. An exact description of the last step before the error or crash occurred.
  2. The error message itself (as a screenshot). To find out how to take a screenshot, look at
    https://connect.allplan.com/en/faqid/0001cb36.html
  3. A support request (Hotinfo) with question 01. To find out how to create a support request, look at
    https://connect.allplan.com/en/faqid/20140528094911.html
  4. The 'Allplan.out' log file. To find out how to create a log file, look at
    https://connect.allplan.com/en/faqid/0001a27a.html
Download PDF  FAQ_EN_Allplan_does_not_start_after_crashing_-_canno...
Version:  Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014  | Last modified: 17.09.2018
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How can I check out a laptop and resume work as a normal CAD user with my usual settings and privileges?



Answer:

Log on as the Allplan administrator to the laptop.



Step 1: add computer to Workgroup Manager
The laptop needs to be integrated in the workgroup so that it can be used for data storage (data server). Do the following:

Create data folders:
Create a folder - &apos;Nemdata&apos;, for example - on the laptop and share it (full control).
Create the &apos;Allplan&apos; subfolder in this folder. Create two subfolders - &apos;usr&apos; and &apos;prj&apos; - in the Allplan folder.
In this example: &apos;...\Nemdata\Allplan\prj&apos; and &apos;...\Nemdata\Allplan\usr&apos;

Add computer:
Start the Services application -> Workgroup Manager -> Administer projects and computer
In the "Remote projects" area on the left, click on Workgroup Server with the right mouse button and select Add computer on the shortcut menu.
Find the computer you want to add, open the local share and select the folder with the &apos;usr&apos; and &apos;prj&apos; subfolders (in this example: &apos;COMPUTERNAME\Nemdata\Allplan&apos;). Confirm by clicking OK.

Install the "Microsoft Loopback Adapter" driver.
This driver is necessary so that network services are always running on the laptop.
Please refer to Allplan Connect for a detailed description: https://connect.allplan.com/en/faqid/000162ae.html


Step 2: move user folder (optional)
Allplan 2013 and later: the user will be move automatically
(Start the Services application -> Workgroup Manager -> Administer users
Click with the right mouse button on selected user who is going to work on the laptop outside the network environment.
Select Properties
In the field user folder select the laptop
Repeat step 2 if several users are to work with the laptop.

Note:
If user folders have been moved to the laptop and this laptop has been checked out, the user in question can only work with the laptop and not in the office.)


Step 3: define project owner
A user can only move a project if he/she is the owner of this project.
The ownership of a project can only be changed by an Allplan administrator (or the owner of the project).
Allplan -> File -> ProjectPilot - Admin... ->
Click the relevant project with the right mouse button and select Properties on the shortcut menu.
Now you can define the owner.


Step 4: move projects
Log on as the user who wants to check out the laptop.
Start the Services application -> Workgroup Manager -> Administer projects and computer
In the "Remote projects" area on the left, select the computer with the projects you want to move.
Drag the projects one after the other to the laptop to be checked out.


Step 5: check out laptop
Start the Services application -> Workgroup Manager -> Administer projects and computer.
Click on your laptop and click on Check out at bottom right.
Confirm the message indicating that there are still user folders on the computer to be checked out.
Enter a comment and click OK. This comment is displayed if users in the office try to access a project on the computer checked out.
Specify which parts of the office standard are to be copied to the laptop and click OK to confirm.



Conclusion:

Now you can remove the laptop from the network and edit your projects when you are out of the office. To make sure that the projects are not changed in the office in the meantime, the projects that are on the computer checked out are locked for the CAD users on the network. These users see the comment you entered when you checked out the computer.


Note:

  • Only the local computer can be checked out (you cannot check out a different computer in the network).
  • Projects on this computer must neither be locked nor in use.


Download PDF  FAQ_EN_Workgroup_manager_checking_out_computer_and_w...
Version:  Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 08.05.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

Suddenly, one of the following error messages pops up: "This license is no longer available", "CmActLicense runtime system is not installed!" or "NemAll_DataResource20.dll: Start Error 102". After this, Allplan does not start anymore. How can I solve this problem?


Answer:

The local Windows service, which is used by licensing, is not running correctly.

If communication with the local Wibu service is blocked, Allplan cannot find the license anymore. This is often caused by the virus scanner.
So you need to exclude the "Codemeter" folder from virus scans.
You can find this folders in the following path:
C:\Program files (X86)\Codemeter
C:\Program files\Codemeter
C:\ProgramData\CodeMeter

Then restart the service:

Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.

CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.



Important note:

Follow this link to find out how to configure the virus scanner in conjunction with real-time scanning. Exclude all Allplan folders with their subfolders from virus scans. You can display the paths to the Allplan folders in the Services application window.

https://connect.allplan.com/en/faqid/20091126145752.html


Download PDF  FAQ_EN_Windows_service_for_licensing_is_blocked_by_v...
Version:  Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 20.09.2018
12 user(s) found this FAQ helpful

Question:

A new computer is to replace the existing one.
How can I transfer the existing data and settings of the existing Allplan installation to the new computer?



Solution:

Please note that this solution only works with stand-alone versions.
Install the same version of Allplan on the new computer and transfer the data as follows:

1st - transferring the data:
Transfer the following folders from the old computer to the new one:
Project folder (PRJ)
Office standard folder (STD) and
User folder (USR)

You can determine the path to these folders on both the new computer and the old computer as follows:
Services application->Service->Hotline Tools->Showcfg: shows system variables ->OK
You can find the paths to the folders after PRJ, STD and USR.

2nd - transferring the toolbar configuration:
Export the configurations from the old computer by clicking View -> Toolbars -> Customize... -> Export...
You can then import the configurations to the new computer by clicking View -> Toolbars -> Customize... -> Import...

Download PDF  FAQ_EN_Installation_on_a_new_computer_with_data_tran...
Version:  Allplan 2019 / Allplan 2018 / Allplan 2017  | Last modified: 08.05.2019
1 user(s) found this FAQ helpful

Question:

ProjectPilot does not open, displaying the following error message:
“Unable to create ProjectPilot control. Is the registry correct?” What can I do?



Answer:

Step 1
Start the Services application -> Service -> Windows Explorer -> CAD program folder.
Open the "PRG" folder.
Find the following file: "NemProjectPilot10.exe"
Right-click this file -> select "Run as administrator" on the shortcut menu.
Try to start ProjectPilot from Allplan.
If ProjectPilot does still not start, go to step 2.


Step 2
Check whether updating the software of the virus scanner solves the problem.
If it doesn't, configure the real-time scanner of the virus scanner so that
it no longer scans the program folder and data folder of Allplan.
Start the Services application: Make a note of the following paths displayed in the Services application window:
Program folder
General program data
Central file storage folder
Define these folders as exemptions in your virus scanner.
If ProjectPilot does still not start, go to step 3.



Step 3
This problem is often caused by an "external path" that no longer exists. When you start ProjectPilot,
the program tries to access the "external path", which is stored in the Windows Registry.
If this path no longer exists, you will see the above error message.

To correct this error, do the following:

  • Start the Services application -> Service -> Windows Explorer -> My own CAD documents (USR).
  • Find the "extern.cfg"file in the user folder and delete this file.


If ProjectPilot does still not start, go to step 4.



Step 4 (Windows 10 or later)
Open the PRG folder of Allplan in Windows Explorer (for example, C:\Programs\Allplan\Allplan 2018\prg).
Start the Services application. The folder you selected for the Allplan program during installation is displayed directly in the Services application window.
Right-click the "NemProjectPilot10.exe" file in the Allplan program folder. A shortcut menu opens. Click “Properties”.
Open the “Compatibility” tab and select the “Disable fullscreen optimizations” option. After having selected this check box, click “Apply” at bottom right.




If several users with different user profiles use Allplan on this computer, click the “Change settings for all users” button first. Then, disable fullscreen optimizations as described above.




If ProjectPilot does still not start, go to step 5.



Step 5
Fix Allplan.
To find out how, go to
https://connect.allplan.com/en/faqid/20120917082945.html
After installation, try to start ProjectPilot.
If ProjectPilot does still not start, go to step 6.



Step 6
If ProjectPilot does still not start, the most likely cause of this problem is security software such as the virus scanner.
Remove, that is, uninstall the local virus scanner with all its services from the Allplan computer having these problems.
After this, ProjectPilot will start.
To reinstall the security software or virus scanner with its appropriate settings,
contact the support service of the software provider.

Download PDF  FAQ_EN_ProjectPilot_does_not_start.pdf
Version:  Allplan 2019 / Allplan 2018 / Allplan 2017  | Last modified: 07.05.2019
4 user(s) found this FAQ helpful

Question:

  • Why can't I create elements?
  • Why can't I move a drawing?
  • Why are elements not created correctly?
  • Why does the program crash when I import a DXF file from the land registry office?
  • Why is the outline of a circumscribed area not detected correctly?
  • Why can't I calculate shadows?
  • Why are elements not displayed correctly in animation?
  • Why are parts of dimension text missing?
  • Why do the contents of the screen suddenly rotate?
  • Why can't I get a preview when I move or copy elements?
  • Why are areas not calculated correctly?




Finding the reason for these problems:

Check whether an offset is set in the project settings (File -> New Project, Open Project-> select the project and open the shortcut menu -> Properties; Allplan 2009 and earlier: Tools -> Options ->Advanced Draft -> Settings). If there are offset coordinates, clear the check box.

Select Tools -> Measure(->)Coordinates.
Click in the middle of the drawing in plan view.
If there are very large values (for example, x/y/z greater than 5000 m), you have found the reason for these problems.

The system has problems calculating and displaying data with very large coordinates. The more data you have with very large coordinates, the greater this effect.



Solution:

  • Click Tools -> Options... -> Desktop environment -> Generaland select Optimize working with large coordinates(Allplan 2009 and earlier: Tools -> Options -> Global Options -> Miscellaneous tab -> Optimize working with large coordinates). After this you must restart Allplan. Otherwise, this setting has no effect.

This is a user setting you must define separately for each user.

  • Usually, the best solution is to move the data towards the Allplan origin. Use the "Move" tool. When Allplan prompts you to specify the target point ("To point"), select Global point in the dialog line. You can find detailed information in the help for Allplan. Look for the Global pointtopic.



Note:

If the data are still not displayed correctly, do the following:
Exit Allplan -> Services application-> Service -> Hotline Tools-> cleanup -> start Allplan.

Download PDF  FAQ_EN_Large_coordinates.pdf
Version:  Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 17.07.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How to update the license server and the licenses?



Answer:

Allplan 2016: Before you do anything, make sure Allplan 2016-1-4 or later is running on all clients.
Allplan 2017 and higher: Check the version of the license server as described below and update the licenses.

1. Updating the license server
Check the version of the license server. You can find detailed information on the version (Build-ID) at bottom left in the License Settings program.
Make sure the version of the license server you use is at least 1.614.x.x. If you cannot see the Build-ID, you work with an older license server.
If this is so, update the license server. Download the software for the license server from Allplan Connect

or from the following link.

https://webdrive.allplan.com/index.php/s/4LrjrymoxESzC6p

The package is in the folder

/Allplan/Lizenzserver/2018/

Start the new License Server Setup on the server or computer you use as the license server. Right-click the *.exe file and select 'Run as administrator' on the shortcut menu.

  • Click Install.
  • Click Exit.

If you have not yet installed the license server or if you have not switched to Allplan 2016 or higer until now, you can find detailed step-by-step instructions at
https://connect.allplan.com/en/faqid/20150618084450.html


2. Updating the licenses
Update the licenses at the license server as follows:

  • Start the License Settingsprogram on the server.
  • Click License activationon the left. Then click the license you want to update so that this license is highlighted in blue.
  • As you can see, the 'Update license' function is now available.
  • Click Update license.
  • If your license includes configurations for several seats, you must update each license separately.

Note: When updating the license it can be that you will receive a higher version of the license as the version of Allplan you are using. The license is downward comatible and can be used until Allplan 2016.

Download PDF  FAQ_EN_Updating_license_server_and_licenses_.pdf ...
1 - 10 (71)
| A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z |
https://campus.allplan.com/ uses cookies  -  More information

Accept