Search Result

1 - 3 (3)
  • 1
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011  | Last modified: 17.10.2019
4 user(s) found this FAQ helpful

Allplan from version 2011

Parts of Allplan 2011 have been reprogrammed and are completely new. Allplan uses a graphics library, which has been developed especially for CAD programs and visualization tasks. Depending on the data type and application, the display speed of Allplan is much higher than that of earlier versions, and refresh operations are considerably shorter. What's more, you can create hidden line images in real time.
This new technology is not a one-to-one implementation of the software-based solution in the previous version. Instead, a hardware-based approach is used. When it comes to data processing, the graphics card takes on much of the work. The different behavior of these two technologies that may occur in some parts is inherent. Therefore, the resulting display and refresh operations may differ slightly from what you are used to.



General graphics card requirements for Allplan

To fully exploit hardware acceleration capabilities, you require an Open GL 2.0 and DirectX10 (chip-based) compatible graphics card with 512 MB or more memory. Although Windows XP does not support DirectX10, Allplan only requires the chip-based support of the graphics card to manage the graphics library. OpenGL 2.0 is used in 2D and in visualization windows. These changes employ the latest technology in graphic display, so selecting a capable graphics card, and using the proper drivers is essential.

For more information on graphics card specifications, go to:

http://en.wikipedia.org/wiki/Comparison_of_AMD_graphics_processing_units
http://en.wikipedia.org/wiki/Comparison_of_NVIDIA_graphics_processing_units#Quadro)



Professional graphics cards versus Consumer-Level cards

Graphic card manufacturers typically have different product lines targeted for "gamers" and "professional users". While the hardware setup is very similar in case of both cards, there are key differences in their firmware and driver. "Consumer-Level cards" (such as Nvidia GeForce and AMD/ATI Radeon) are optimized for 3D games and technologically designed for DirectX10, as speed is more important than image quality.
Typically a 3D model in a game contains a low number of polygons with textures applied to them, while in CAD applications polygon count is high, and the image quality of wireframe models or shaded models is more important than navigation speed. Also, professional cards' memory usage is optimized for using multiple application windows, while in gaming this is not relevant.
Another key difference between the two product lines is the way they are delivered and supported. Professional cards (such as Nvidia Quadro and AMD/ATI FireGL/PRO) are built according to the video chip manufacturer's references, so you can always be sure that the driver delivered by the video chip manufacturer (such as Nvidia or AMD/ATI) fits your card.
The manufacturers of Consumer-Level cards (such as ASUS, Sapphire, Gigabyte, PNY and so on) may diverge from the chip manufacturer's references, so their drivers may not be compatible with the chip manufacturer's reference driver. Also, the product life cycle and driver release cycles are much shorter in case of gaming cards, usually 6 months up to 1 year at most and a 1-year warranty period maximum.

Example: comparison of graphics cards

Consumer-Level cards
Professional graphics cards / workstation
Products
Radeon
FireMV
FireGL/Pro
Mobility FireGL/Pro
Markets
  • Private customers: desktop systems and notebook systems
  • Corporate desktop systems
  • Corporate CAD and DCC desktop systems and notebook systems
Applications
  • Home/office publishing, productivity, multimedia, games, Internet
  • Finance, clearance, logistics, airport information displays
  • CAD/CAM/CAE, AEC, DCC, GIS, MI, visual simulation, scientific research/imaging
Certification
  • WHQL certification
  • Industrial applications
  • WHQL certification
  • Professional 3D applications
  • WHQL certification
Operating
systems
  • Windows 98SE / Me / XP
  • Windows Vista,
    Windows 7
  • Windows XP, XP64,Vista, Vista 64, Windows 7, Windows 7 64
  • Linux
Drivers
  • Optimized for DirectX
  • Basic Open GL
  • Optimized and designed for DirectX
  • Optimized and advanced Open GL
Life cycle
  • Available for 1 year on average
  • Available for 2-3 years on average
Support
  • Basic, private customers
  • Direct access to dedicated support by trained technicians
Warranty
  • 1 year
  • 3 years with replacementof components




Professional graphics cards versus Consumer-Level cards

Professional graphics cards differ considerably from "Consumer-Level cards" for private users with regard to specific market segments with special requirements:

  • Extensive application tests and certifications with CAD providers
  • Optimized and advanced support for API as well as further developments
  • Longer product life cycles and availability
  • Direct product support
  • Longer warranty period


Nemetschek Allplan GmbH cooperates with Nvidia und AMD to test graphics card drivers for the Nvidia FX Quadro/ Quadro and AMD/ATI FireGL/ Fire Pro series. These product lines are tested, certified and recommended for Allplan by Nemetschek Allplan Systems GmbH.

For more information on certified graphics cards, go to:

www.nemetschek.eu/info/grafikkarten
www.nemetschek.eu/info/graphiccards

There are four different categories and areas:

Graphics cardApplicationQuality testsStatus
Gaming graphics cards3D GamesTested / not testedNot recommended
    
Professional graphics cards3D basisCertified and recommendedEnd of life
    
Professional graphics cards3D performanceCertified and recommendedEnd of life
    
Professional graphics cards3D high performanceCertified and recommendedEnd of life




Recommended graphics cards for laptops (Windows)

For reasons detailed above, we cannot recommend any specific card and driver combination for laptops. However, there are professional graphics cards available for high-end laptops such as NVidia FX Quadro & Quadro NVidia "M" or AMD/ATI FireGL & FirePro "Mobility".
These graphics cards are just as good as their desktop counterparts.
Laptops with Consumer-Level cards have been tested only briefly and cannot be recommended. We have had bad experience with on-board Intel graphics cards.



Graphics cards drivers for Apple Macintosh

Since Macs come with a default graphics card (on-board or gaming), and the drivers are bundled with system updates, we cannot recommend a specific card.
Graphics cards for MacOsX 10.6 (Leopard) or later and Boot Camp support Open GL 2.0 and DirectX10. Currently, there is only one series that is equipped with a professional graphics card: Mac Pro with NVidia FX4800 for Mac.


Notes for Allplan and Macintosh:

  • There is no provision for a direct installation under Macintosh.
  • Access to Windows must be straight from the Boot Camp installation.
  • For performance reasons, Parallels Desktop cannot be used in conjunction with Nemetschek Allplan.


We kindly ask you to understand that Nemetschek Allplan cannot provide support for Boot Camp installations.



Installing graphics cards drivers (Windows)

Graphics cards only work properly if they have a hardware provider supplied driver (not system built-in driver) installed correctly. It may happen that remnants of a previous installation interfere with the current driver installation. If you experience display issues with the drivers listed below, please "clean-install" the driver again. "Clean-install" means removing all previous driver files before installing a new driver. Unfortunately, a simple uninstall may not efficiently remove all components of a driver. There are tools that can do it, like ATI's cat uninstaller or third-party tools like driver cleaner or driver cleaner pro 1.5.



Graphics card drivers for laptops (Windows)

In most cases, graphic card drivers for laptops are supplied by the laptop manufacturer, and graphic card provider supplied drivers will not install on laptops. This makes it practically impossible for us to test laptop graphics cards. If you are experiencing display issues with your laptop, and your supplier does not offer you a driver update, you might try - at your own risk - to tweak a desktop driver to work on your laptop. Note that this is obviously not encouraged by your laptop supplier.

Download PDF  FAQ_EN_Graphics_cards_for_Allplan.pdf
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012  | Last modified: 28.10.2019
1 user(s) found this FAQ helpful

Task:

You have installed Allplan on several local workstations. Now you want to change the installation so that you can access a common network drive.



Note:

Before you switch to a network installation, it is essential that you back up all the data of all the workstations.
We strongly recommend that you take advantage of the expertise of Nemetschek’s technical support staff. We are happy to help you!



Solution:

The following description shows how to change several workstations where Allplan is installed locally and the project data is also stored locally on each computer to workstations with a common network drive without Workgroup Manager.

1st - getting ready
Choose one of the workstations where you will install all the projects and the office standard (hereinafter referred to as the main workstation).
First, move all the projects to the main workstation.

1.a: copying resources into projects
To make sure that the projects in your office have a uniform appearance, change the path settings for the projects' resources to 'Project'.
Make the following setting for each project:
Allplan -> File menu -> ProjectPilot - Admin -> select the individual projects one after the other -> right mouse button -> Properties -> Settings tab
Set the path settings for 'Pen and line definitions', 'Fonts', 'Patterns, hatching styles, area styles', 'Bar and mesh cross-section catalogs', 'Layer structures, line styles, drawing types' and 'Attributes proposed' from 'Office' to 'Project', if necessary.
The corresponding elements are copied from the office standard directly to the project. This ensures that the project settings stay the same even when you copy the project to the new server with the new office standard.

1.b: same folder name as project name
Open the 'General' tab and select the 'Same folder name as project name' setting if you want to proceed as described in 2b.

1.c: pen color ("Color stands for pen")
The pen color for the "Color stands for pen" setting is a user-specific setting that is not saved in the project but in the user folder (...\Usr).

2.a: backing up projects of the individual workstations and importing them to the main workstation (recommended method):
Back up the individual projects. To do this, open the Services application and select Data Backup -> Create -> Entire folders -> Projects.
You can back up several projects in a single operation.
Before you start, specify the backup folder on the network or on the local hard disk: Services application -> Configuration -> Backup path ->Browse for Folder.

The next step is to import the saved projects to the main workstation.To do this, open theServices application -> Data Backup -> Import -> Projects Before you import the individual projects, you can create new Allplan projects at the main computer. As an alternative, you can also create a new project during the import.

2.b: backing up projects of the individual workstations and importing them to the main workstation (special approach):
This approach should only be used with good reason for exceptional cases as it requires in-depth knowledge of Windows.
With this method, Windows Explorer is used to import the projects to the main workstation.
If some project names exist twice, you need to rename these projects before you back them up.

You can then rename the existing 'project.dat' file in the Prj folder of the main workstation.
Next, select the Services application -> Service -> Hotline Tools -> reorg -> Restore project management file.
The system creates a new project administration file (project.dat), which should list all projects with names.

Now the main workstation contains the latest version of all the projects of the office.

3rd - merging project defaults
Open ProjectPilot at the individual workstations and copy the elements you want to transfer (symbols, smart symbols, lists, schedules, and so on) to the external path. Of course, you can set the external path to a common network folder that can be accessed by all workstations.
Next, open ProjectPilot at the main workstation and copy the contents of the external path to the office standard.

4th - data backup

  • Back up the projects, office standard and user settings at the main workstation:
    You can also copy the ..\prj (projects), ..\std (office standard) and ..\usr (user folder) paths to a backup folder (Nemsic, for example) on the hard disk.
  • In addition, you need to back up the ..\usr\local folder at every stand-alone computer.
  • Export the user interface setting of each user to a file: Allplan -> Tools - > Customize .... -> Export...


5th - uninstalling
Remove Allplan from all workstations.

6th - reinstalling
Before you install the same version again, create and share a folder (Nemdata, for example) on the future data server. Create a subfolder - Allplan - in this folder.

The next step is to reinstall the same version on all the workstations.

Specify the following installation paths:
Program folder:
local (C:\Programs\Nemetschek\Allplan, for example)
Central file storage folder:
Browse -> Network...
Find the sharedNemdata folder and select the Allplan folder.

After this, start installing.

7th - testing the start and restoring the backup
After the installation (check whether Allplan starts), copy the ..\prj and ..\std folders you backed up from the main workstation to the new ...\Nemdata\Allplan server folder.

Next, use Windows Explorer to copy the contents of the former user folder (…\usr\local) of the stand-alone workstation to the new user folder of the computer you just installed.

8th - updating the project administration file
Go to the project.datfile in the ...\Nemdata\Allplan\Prjfolder and rename itproject.alt.After this, do the following:
Services application -> Service -> Hotline Tools -> reorg -> Restore project management file.

9th - summary
Now all the workstations access a common network drive with the same project pool and office standard.
With this type of installation, only one user can access a project at any one time. If several users are to work on a project at the same time, you need to install Workgroup Manager.

Download PDF  FAQ_EN_Switching_from_single_installation_to_network...
Version:  Allplan 2014 / Allplan 2013 / Allplan 2012  | Last modified: 04.01.2018
5 user(s) found this FAQ helpful

Question:

After I have updated the driver of a graphics card from the Nvidia Quadro or GeForce series, I cannot start Allplan anymore.
I can see numerous error messages. What can I do?



Answer:

Allplan no longer starts after you have installed a current driver of the Nvidia GeForce or Nvidia Quadro WHQL series.


You can solve the problem as follows:

For customers running Allplan 2014:
Install at least version 2014-1-3. This version works with the drivers mentioned above.

For customers running Allplan 2013 or an earlier version:
Start the Services application.
Select Service -> Windows Explorer -> General program data.
(Allplan 2012: Services application -> Service -> Windows Explorer (program folder))
Open the ETC folder and then the "Shaders" folder, for example, C:\ProgramData\Nemetschek\Allplan\2013\Etc\Shaders.
Find the "Postprocess.frag" file and rename it "Postprocess.OLD".
Copy the "Postprocess.frag" file, which you can find attached to this FAQ, into the "Shaders" folder.

A note on Allplan 2014-1-3:
Download this version from Allplan Connect or from the FTP server.

Allplan Connect:
https://connect.allplan.com/de/support/downloads.html

FTP server:
ftp://nemhotline:ha37jvg8f@ftp.nemetschek.de/download/Allplan/2014/CD/
Copy this link and paste it into the address bar of Windows Explorer. Then press ENTER.
This opens the folder on our FTP server.
Select the appropriate file (for example, 'DoWn-allplan2014-1-3_x64-cad.zip' for 64-bit systems) and select Edit -> Copy (Ctrl+C). (If you run the Windows 32-bit system, download the other file.)
Switch to a folder on your computer and select Edit -> Paste (Ctrl+V).
After having downloaded the file, you can decompress it and start installing it by double-clicking the exe file.
To download large files, you can also use a download client, such as Filezilla (http://filezilla-project.org/).

Download PDF  FAQ_EN_Allplan_does_not_start_after_update_of_graphi... Download Postprocess.frag
1 - 3 (3)
  • 1
| A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z |
https://campus.allplan.com/ uses cookies  -  More information

Accept