4 user(s) found this FAQ helpful

Question:

I purchased the license server. How can I install and configure the license server?



Answer:

Allplan is using since version 2016 a new protection system. Licensing is based on CodeMeter by Wibu Systems AG since then. You can no longer use NemSLock Server with Allplan 2016 and higher.

Allplan requires a Product Key. Using this key, you can activate your license online. The Product Key is a unique, 26-digit character string. You can use it to activate a license for Allplan.
You can find your Product Key in Allplan Connect. Go to http://connect.allplan.com/license
Note: The license is downwards compatible til version Allplan 2016-1-4 even if a higher version is displayed.



To install the license server, download the software for the license server from Allplan Connect
or from our FTP server:
ftp://nemhotline:ha37jvg8f@ftp.nemetschek.de/download/Allplan/Lizenzserver/2017/DoWn-License_Server_Setup.zip

The Wibu license server is part of the CodeMeter driver, which is installed along with Allplan. If you have already installed Allplan on the license server, you do not have to install additional software. But you can also install the license server separately; you do not have to install Allplan.
In any case, install and activate the license server before you install Allplan on the clients.

You can activate a license in online mode only if you have ...

  • Internet access
  • a Product Key
  • a license server license; you cannot use other licenses with the license server.




Installing the license server

  • You must install the license server on a 64-bit Windows system.
  • Start License Server Setup on the computer you want to use as the license server.
  • Click Install.
  • Start the license server by starting the License Settings program. Go to the License activation area, enter your Product Key and click Activate license.
  • If you have more licenses for the license server, enter the respective Product Keys and activate the licenses.
  • Afterwards, start CodeMeter Control Center.

To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen: enter Codemeter and press ENTER. A dialog box opens. Click WebAdmin at bottom right.

Or
Enter Localhost:22350in the address bar of your browser.

  • Select Configuration -> Server -> Access server in the Network server area and click Activate.
  • Click Apply.



Configuring the license server (optional)

You can use the CodeMeter WebAdmin application to administer the license server.
To start and stop the license server service, you can use CodeMeter Control Center.

  • CodeMeter Control Center -> Action -> Start or Stop CodeMeter Service


Access control
By default, all users on the LAN, who have installed the CodeMeter driver, can use a license from the license server.

  • Basic access control: you can enter a list of client computer names or IP addresses that are allowed to access the license server.
  • Advanced access control: you can specify global access rules (for all licenses) to control access to the licenses.


License tracking
To activate license tracking, you have to set the HKEY_LOCAL_MACHINE\SOFTWARE\WIBU-SYSTEMS\CodeMeter\Server\CurrentVersion\LogLicenseTracking registry entry to 1 and restart CodeMeter Service.

After having activated this key, you can use CodeMeter WebAdmin to create a report showing details about the licenses used over a specific period of time. To do this, open CodeMeter WebAdmin and go to the 'Server' - 'License Tracking' page. Select the period of time and the license for which you want to generate a report. Then click 'Create report'. If you click a single bar, you will get detailed analyses per day or per hour.

CodeMeter WebAdmin saves the reports to C:\ProgramData\CodeMeter\Logs.



Installing and configuring clients

Note for Version 2016: Install at least Allplan 2016-1-4 on the clients.

The license server license will be detected automatically on the network.
Install Allplan on the clients. When you are prompted to select the license file, click Use active license. Follow the installation instructions.

  • You do not need to activatethe clients.


Allplan automatically finds the license server on the local network. If you have not selected a license, Allplan automatically selects the first available license.

After having installed Allplan on the clients, you can use the 'License Settings' dialog boxto configure license selection.
Services application -> Utilities -> License settings

Areas:

  • License activation: this area is not relevant to clients taking their license from the license server.
  • License selection: use this section if you get the license from a license server or if you have several licenses and you want to select the preferred license.
  • Start as a viewer: click this button if you want to start Allplan as a viewer.



License selection

You can see the names of the available licenses with their seat numbers.
The 'Available' column indicates how many licenses are still available. Click the dropdown arrow to see a list of users currently working with a license.

Priority:
Select the check box in front of a license to select this license as a favorite. You can mark as many licenses as you want. Allplan will then prefer these licenses. Click to select one ore more licenses Allplan is not to use. If you do not select any license or if you have selected several favorites, Allplan will automatically use the first free license it finds.

Find license server automatically:
When you select this option, Allplan automatically detects a license server on the LAN. In some cases, such as VPN connections, Allplan may not be able to detect a server automatically. In this case, you can enter the server manually (see Additional server name).
Note: Only the Windows administrator can change this option.

Additional server name:
If 'Find license server automatically' is not active or Allplan has not automatically found a license server, you can manually enter the name or the IP address of the server. If 'Find license server automatically' is active, you can enter an additional server. After having entered the server name, click 'Update' to see the licenses of the license server. Use semicolons to separate several server names.


Note:

You can find detailed information on the license server in the License Settings help (F1 key).

Allplan communicates with the license server via TCP/IP. By default, communication is via Port 22350 unless you change the port in CodeMeter WebAdmin.

If a firewall is active on your computer, you must enable port 22350 for TCP and UDP. If the firewall filters in an application-specific manner, you have to enable the CodeMeter.exe license server service. You can find this service in the %Program Files (x86)%\CodeMeter\Runtime\bin Windows folder. Define the CodeMeter.exe service as an exception in the firewall. Some anti-virus programs also include firewall functions. If you are not sure, contact the manufacturer of the anti-virus program.

Загрузка PDF  FAQ_EN_Installing_and_configuring_the_license_server...
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018  | Последнее изменение: 03.11.2020
4 user(s) found this FAQ helpful

Question:

  • Why can't I create elements?
  • Why can't I move a drawing?
  • Why are elements not created correctly?
  • Why does the program crash when I import a DXF file from the land registry office?
  • Why is the outline of a circumscribed area not detected correctly?
  • Why can't I calculate shadows?
  • Why are elements not displayed correctly in animation?
  • Why are parts of dimension text missing?
  • Why do the contents of the screen suddenly rotate?
  • Why can't I get a preview when I move or copy elements?
  • Why are areas not calculated correctly?




Finding the reason for these problems:

Check whether an offset is set in the project settings (File -> New Project, Open Project-> select the project and open the shortcut menu -> Properties; Allplan 2009 and earlier: Tools -> Options ->Advanced Draft -> Settings). If there are offset coordinates, clear the check box.

Select Tools -> Measure(->)Coordinates.
Click in the middle of the drawing in plan view.
If there are very large values (for example, x/y/z greater than 5000 m), you have found the reason for these problems.

The system has problems calculating and displaying data with very large coordinates. The more data you have with very large coordinates, the greater this effect.



Solution:

  • Click Tools -> Options... -> Desktop environment -> Generaland select Optimize working with large coordinates(Allplan 2009 and earlier: Tools -> Options -> Global Options -> Miscellaneous tab -> Optimize working with large coordinates). After this you must restart Allplan. Otherwise, this setting has no effect.

This is a user setting you must define separately for each user.

  • Usually, the best solution is to move the data towards the Allplan origin. Use the "Move" tool. When Allplan prompts you to specify the target point ("To point"), select Global point in the dialog line. You can find detailed information in the help for Allplan. Look for the Global pointtopic.



Note:

If the data are still not displayed correctly, do the following:
Exit Allplan -> Services application-> Service -> Hotline Tools-> cleanup -> start Allplan.

Загрузка PDF  FAQ_EN_Large_coordinates.pdf
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 24.10.2019
3 user(s) found this FAQ helpful

Question:

Allplan does not start. When you open license selection in the license settings, you can see the following message: "Cannot find a license for running Allplan." Sometimes you might also see one of the following error messages: "This license is no longer available", "CmActLicense runtime system is not installed!" or "NemAll_DataResource20.dll: Start Error 102". Allplan no longer starts after these messages. How to solve this problem?

Answer:

Check the following points:

On the client:

Open the license settings: Services application -> Utilities -> License settings

1. Has the license been blocked on the client?
Check the 'License selection' area to find out whether your license has been blocked. This is indicated by the symbol. If the license is blocked, Allplan cannot use it.
Click this symbol to unblock the license again. If you want, you can select the check box in front of the license to select it as a favorite. Allplan will then prefer this license.
If you do not select any license or if you have selected several favorites, Allplan will automatically use the first free license it finds.


2. Has the server been found?

Select the 'Find license server automatically' option. You should now see the license provided by the server.

Note: In some cases, such as VPN connections, Allplan may not be able to detect a server automatically. In this case, you can enter the server manually.


3. Is the local Windows service, which is used by licensing, running correctly?

If communication with the local Wibu service is blocked, Allplan cannot find the license anymore. This is often caused by the virus scanner.
So you need to exclude the "Codemeter" folder from virus scans. You can find this folder in the following path: C:\Program files (X86)\Codemeter or C:\Programme (x86)\Codemeter

Then restart the service:

Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.

CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.


On the license server:

4. Is the 'Start network server' option active?

Start CodeMeter Control Center on the server.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen, enter Codemeter and press ENTER. A dialog box opens. Click WebAdmin at bottom right.

Or
Enter Localhost:22350in the address bar of your browser.

  • Select Settings -> Server -> Access serverin the Network serverarea and click Activate.


Update the license settings on the client. To do this, click Updateor open the dialog box with the license settings again. You should now see the license on the client.


5. Restart the license server service on the server

To start and stop the license server service, you can use CodeMeter Control Center.

  • CodeMeter Control Center -> Action -> Stop CodeMeter Service
  • CodeMeter Control Center -> Action -> Start CodeMeter Service


Update the license settings on the client. To do this, open the dialog box with the license settings again. You should now see the license on the client.


6. Is the virus scanner blocking the Windows service, which is used by licensing, at the server?

If communication with the Wibu service is blocked, Allplan cannot find the license anymore. This is often caused by the virus scanner.
So you need to exclude the "Codemeter" folder from virus scans.
You can find this folder in the following path: C:\Program files (X86)\Codemeter or C:\Programme (x86)\Codemeter
In addition, exclude the C:\Program Files\Allplan GmbHfolder.

Then restart the license server service:
If the service is running, stop it and restart it.


7. Check the firewall

Allplan communicates with the license server via TCP/IP. By default, communication is via port 22350 unless you change the port in CodeMeter WebAdmin. So you need to configure the firewall accordingly.

If a firewall is active on your computer, you must enable port 22350 for TCP and UDP. If the firewall filters in an application-specific manner, you have to enable the CodeMeter.exe license server service. You can find this service in the %Program Files (x86)%\CodeMeter\Runtime\bin Windows folder. Define the CodeMeter.exe service as an exception in the firewall. Some anti-virus programs also include firewall functions. If you are not sure, contact the manufacturer of the anti-virus program.

Загрузка PDF  FAQ_EN_License_server_-_cannot_find_a_license_.pdf ...
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 30.09.2020
7 user(s) found this FAQ helpful

Question:

My computer does not have Internet access, but I would like to activate the license with the Product Key. What can I do?


Information:

The easiest way to activate and return Allplan licenses is to do this online. In other words, the computer has Internet access. However, you can also activate Allplan on a computer without Internet access (offline licensing). Offline licensing is particularly useful if some Allplan computers in your office do not have Internet access and do not use a license server either.

If the computer without Internet access and the computer with Internet access are neither close to each other (for example, the computer in the office hasInternet access, but the computer at home does not haveInternet access) nor connected with each other (for example, using LAN), offline activation is not very suitable, as you have to access both the computer with Internet access and the computer without Internet access.

Requirements for activating a license offline:

  • You have a valid Product Key.
  • You have installed Allplan on the computer without Internet access (for example, as a viewer).
  • You have another computer with Internet access.


Important: Activating a license offline involves two steps. In addition, you need to upload a receipt file so that you can return the license offline later.

There are the following basic steps:

  • Creating and uploading the license request file
  • Downloading and importing the license update file
  • Creating and uploading the receipt file


The online computer uses the following web page:
http://lc.codemeter.com/59885/depot/index.php


Note:

As both the license file and the receipt file are saved with the name of the container number by default, it may happen that you mix up these two files. Therefore we strongly recommend that you use meaningful names for the files. For example, the name could include the name of the computer and the Product Key or the words “license” and “receipt”.
This is particularly important if you want to activate several computers offline.


Answer:

A: Activating licenses offline

To activate licenses, use CodeMeter Control Center.

Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. An an alternative, go to the Windows search box and type Codemeter.

You can find the container numbers in the ‘License’ area.
If you have a stand-alone license, the name of this container is Allplan GmbH and its number is 327XXXXXXX.

Select this container and click Activatelicense on the right. Select
Create license request. Create a *.WibuCmRaC file for your container.

Take this file to a computer that is online.
Go to the following web page:
http://lc.codemeter.com/59885/depot/index.php

Enter your Product Keyin the “Ticket” line and click Next. You can now see your license.
Click Activate license.

You can see your license and all available updates, which should be selected. Click Offline License Transferat the bottom on the right.

You can now upload the *.WibuCmRaC file (Browse....) by clicking Upload license request now. This creates your license, which you can download by clicking Download license update file now. Install this license on your computer.

To do this, go to CodeMeter Control Center and click File-> Importlicense.


You can see the activated license in the Services application -> Utilities -> License settingsand you can now use this license for Allplan.


Finally, upload the receipt file.
To do this, open CodeMeter Control Centeragain and select the new Allplan GmbH license with the number 128-XXXXXXX.

Then click License update -> Next -> Create receipt.
Create the receipt file for this container.
Upload this receipt file using the web page.

Take this file to the computer that is online. Click Nexton the web page.
If you have already closed the web page, use the link given above and enter your Product Key once again. Then select Continue with license transfer.
Select the receipt file and click Upload receipt now.
Click OKto confirm. This completes license activation.




B: Returning licenses offline

You can return licenses in the same way:
Start CodeMeter Control Center and select the container with the license (Allplan GmbH with the number 128-XXXXXXX). Then click License update -> Next -> Create license request.
Here, too, create a *.WibuCmRaC file for your container.

Take this file to a computer that is online.
Here, too, go to the following web page:
http://lc.codemeter.com/59885/depot/index.php

Enter your Product Keyin the “Ticket” line and click Next. You can now see your license.
Click Move license.
Click Offline License Transferat the bottom on the right.
You can now upload the *.WibuCmRaC file (Browse....) by clicking Upload request now.
Then click Download license update file now. Download the file and import it. To do this, go to CodeMeter Control Centerand click File -> Importlicense.

Then create a receipt by clicking License update -> Next -> Create receipt.
Upload this receipt file using the web page.
To do this, click Nexton the web page.
If you have already closed the web page, use the link given above and enter your Product Key once again. Then select Continue with license transfer.
Select the receipt file and click Upload receipt now.
Click OKto confirm. This completes license activation.

The license is now available again and can be used on another computer.

Загрузка PDF  FAQ_EN_Activating_license_offline_(without_Internet_...
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011  | Последнее изменение: 17.10.2019
5 user(s) found this FAQ helpful

Allplan from version 2011

Parts of Allplan 2011 have been reprogrammed and are completely new. Allplan uses a graphics library, which has been developed especially for CAD programs and visualization tasks. Depending on the data type and application, the display speed of Allplan is much higher than that of earlier versions, and refresh operations are considerably shorter. What's more, you can create hidden line images in real time.
This new technology is not a one-to-one implementation of the software-based solution in the previous version. Instead, a hardware-based approach is used. When it comes to data processing, the graphics card takes on much of the work. The different behavior of these two technologies that may occur in some parts is inherent. Therefore, the resulting display and refresh operations may differ slightly from what you are used to.



General graphics card requirements for Allplan

To fully exploit hardware acceleration capabilities, you require an Open GL 2.0 and DirectX10 (chip-based) compatible graphics card with 512 MB or more memory. Although Windows XP does not support DirectX10, Allplan only requires the chip-based support of the graphics card to manage the graphics library. OpenGL 2.0 is used in 2D and in visualization windows. These changes employ the latest technology in graphic display, so selecting a capable graphics card, and using the proper drivers is essential.

For more information on graphics card specifications, go to:

http://en.wikipedia.org/wiki/Comparison_of_AMD_graphics_processing_units
http://en.wikipedia.org/wiki/Comparison_of_NVIDIA_graphics_processing_units#Quadro)



Professional graphics cards versus Consumer-Level cards

Graphic card manufacturers typically have different product lines targeted for "gamers" and "professional users". While the hardware setup is very similar in case of both cards, there are key differences in their firmware and driver. "Consumer-Level cards" (such as Nvidia GeForce and AMD/ATI Radeon) are optimized for 3D games and technologically designed for DirectX10, as speed is more important than image quality.
Typically a 3D model in a game contains a low number of polygons with textures applied to them, while in CAD applications polygon count is high, and the image quality of wireframe models or shaded models is more important than navigation speed. Also, professional cards' memory usage is optimized for using multiple application windows, while in gaming this is not relevant.
Another key difference between the two product lines is the way they are delivered and supported. Professional cards (such as Nvidia Quadro and AMD/ATI FireGL/PRO) are built according to the video chip manufacturer's references, so you can always be sure that the driver delivered by the video chip manufacturer (such as Nvidia or AMD/ATI) fits your card.
The manufacturers of Consumer-Level cards (such as ASUS, Sapphire, Gigabyte, PNY and so on) may diverge from the chip manufacturer's references, so their drivers may not be compatible with the chip manufacturer's reference driver. Also, the product life cycle and driver release cycles are much shorter in case of gaming cards, usually 6 months up to 1 year at most and a 1-year warranty period maximum.

Example: comparison of graphics cards

Consumer-Level cards
Professional graphics cards / workstation
Products
Radeon
FireMV
FireGL/Pro
Mobility FireGL/Pro
Markets
  • Private customers: desktop systems and notebook systems
  • Corporate desktop systems
  • Corporate CAD and DCC desktop systems and notebook systems
Applications
  • Home/office publishing, productivity, multimedia, games, Internet
  • Finance, clearance, logistics, airport information displays
  • CAD/CAM/CAE, AEC, DCC, GIS, MI, visual simulation, scientific research/imaging
Certification
  • WHQL certification
  • Industrial applications
  • WHQL certification
  • Professional 3D applications
  • WHQL certification
Operating
systems
  • Windows 98SE / Me / XP
  • Windows Vista,
    Windows 7
  • Windows XP, XP64,Vista, Vista 64, Windows 7, Windows 7 64
  • Linux
Drivers
  • Optimized for DirectX
  • Basic Open GL
  • Optimized and designed for DirectX
  • Optimized and advanced Open GL
Life cycle
  • Available for 1 year on average
  • Available for 2-3 years on average
Support
  • Basic, private customers
  • Direct access to dedicated support by trained technicians
Warranty
  • 1 year
  • 3 years with replacementof components




Professional graphics cards versus Consumer-Level cards

Professional graphics cards differ considerably from "Consumer-Level cards" for private users with regard to specific market segments with special requirements:

  • Extensive application tests and certifications with CAD providers
  • Optimized and advanced support for API as well as further developments
  • Longer product life cycles and availability
  • Direct product support
  • Longer warranty period


Nemetschek Allplan GmbH cooperates with Nvidia und AMD to test graphics card drivers for the Nvidia FX Quadro/ Quadro and AMD/ATI FireGL/ Fire Pro series. These product lines are tested, certified and recommended for Allplan by Nemetschek Allplan Systems GmbH.

For more information on certified graphics cards, go to:

www.nemetschek.eu/info/grafikkarten
www.nemetschek.eu/info/graphiccards

There are four different categories and areas:

Graphics cardApplicationQuality testsStatus
Gaming graphics cards3D GamesTested / not testedNot recommended
    
Professional graphics cards3D basisCertified and recommendedEnd of life
    
Professional graphics cards3D performanceCertified and recommendedEnd of life
    
Professional graphics cards3D high performanceCertified and recommendedEnd of life




Recommended graphics cards for laptops (Windows)

For reasons detailed above, we cannot recommend any specific card and driver combination for laptops. However, there are professional graphics cards available for high-end laptops such as NVidia FX Quadro & Quadro NVidia "M" or AMD/ATI FireGL & FirePro "Mobility".
These graphics cards are just as good as their desktop counterparts.
Laptops with Consumer-Level cards have been tested only briefly and cannot be recommended. We have had bad experience with on-board Intel graphics cards.



Graphics cards drivers for Apple Macintosh

Since Macs come with a default graphics card (on-board or gaming), and the drivers are bundled with system updates, we cannot recommend a specific card.
Graphics cards for MacOsX 10.6 (Leopard) or later and Boot Camp support Open GL 2.0 and DirectX10. Currently, there is only one series that is equipped with a professional graphics card: Mac Pro with NVidia FX4800 for Mac.


Notes for Allplan and Macintosh:

  • There is no provision for a direct installation under Macintosh.
  • Access to Windows must be straight from the Boot Camp installation.
  • For performance reasons, Parallels Desktop cannot be used in conjunction with Nemetschek Allplan.


We kindly ask you to understand that Nemetschek Allplan cannot provide support for Boot Camp installations.



Installing graphics cards drivers (Windows)

Graphics cards only work properly if they have a hardware provider supplied driver (not system built-in driver) installed correctly. It may happen that remnants of a previous installation interfere with the current driver installation. If you experience display issues with the drivers listed below, please "clean-install" the driver again. "Clean-install" means removing all previous driver files before installing a new driver. Unfortunately, a simple uninstall may not efficiently remove all components of a driver. There are tools that can do it, like ATI's cat uninstaller or third-party tools like driver cleaner or driver cleaner pro 1.5.



Graphics card drivers for laptops (Windows)

In most cases, graphic card drivers for laptops are supplied by the laptop manufacturer, and graphic card provider supplied drivers will not install on laptops. This makes it practically impossible for us to test laptop graphics cards. If you are experiencing display issues with your laptop, and your supplier does not offer you a driver update, you might try - at your own risk - to tweak a desktop driver to work on your laptop. Note that this is obviously not encouraged by your laptop supplier.

Загрузка PDF  FAQ_EN_Graphics_cards_for_Allplan.pdf
Версия:  Allplan 2019  | Последнее изменение: 12.11.2018
Not voted yet. Be the first to vote this FAQ as helpful!

Information:

This document provides further information on installing Allplan 2019.

Backing up and archiving data:

We strongly recommend that you back up and archive all your data before you upgrade to Allplan 2019.


How to install


You can find detailed instructions on how to install Allplan 2019 in the following places:

- After you have downloaded and unzipped Allplan 2019, you can find the ‘install.chm’ file in the following folder: C:\Users\Public\Documents\Allplan 2019\HelpFiles\English.

- Use the following link:
https://webdrive.allplan.com/s/4LrjrymoxESzC6p and open the General\Installation help\2019 folder.


Please read these instructions before you install Allplan 2019.

System requirements for Allplan 2019

https://connect.allplan.com/en/faqid/20180608093815.html

How to handle licenses when upgrading to Allplan 2019

https://connect.allplan.com/en/faqid/20180608092654.html



Some notes on installing Allplan 2019

If you want to switch from Allplan 2016/2017/2018 to Allplan 2019, you can choose between three installation options. We recommend using the second option: first-time installation and copy data from Allplan 2016/2017/2018.

1. First-time installation

This option installs Allplan 2019 to a new folder without affecting any other Allplan installation (2018 or earlier). Setup does not transfer any data or settings to the new installation.

If you want to transfer data later, you have the following options:

You can uninstall Allplan 2019 and then upgrade from Allplan 2016/2017/2018.
You can integrate the data manually (requires administrative knowledge).

2. First-time installation and copy data from version

This option installs Allplan 2019 to a new folder without affecting any other Allplan installation (2018 or earlier). You can configure Setup to automatically copy the office standard (\std), projects (\prj) and user data (\usr) from Allplan 2016/2017/2018 to the new installations folder.
This duplicates the data: You can use all projects, defaults and resources both in Allplan 2018 and in Allplan 2016/2017/2016. This way, you can test the new version without losing your 'old' Allplan version.
Bear in mind, though, that you should not mix data from different versions. Merging data later involves considerable time and effort.

2a. Continue with first-time installation and copy data from version

This option is available when you have already used the second installation option to install <Product_Version> to a computer that accesses the same data server. As a result, the data are already available.

3. Upgrade and transfer data from Allplan 2016/2017/2018

This option installs Allplan 2019 to an existing folder, converting Allplan 2016/2017/2018 to Allplan 2019 and transferring all important settings. Afterwards, you can no longer work with Allplan 2016/2017/2018.
This does nor affect earlier Allplan versions (Allplan 2015 or earlier).


Installing on a network:

  • If you work in a network environment (one common central file storage folder), you must upgrade all workstations to Allplan 2019. Beforeyou start installing, make sure that all workstations can be upgraded. For technical reasons, it is not possible to mix installations of different major releases. Any related problems area not covered by service contracts.
  • During the upgrade, Allplan 2016/2017/2018 must not be running on any workstation.
  • When installing with Workgroup Manager, make sure all workstations are checked in before you start upgrading.





Converting the data:

Data from earlier Allplan versions need to be converted to version 2019. Allplan 2019 automatically converts the data of a project you open. Click here for instructions on how to convert all projects in a single operation:

https://connect.allplan.com/en/faqid/20090408124904.html


IBD 2019

Click here for instructions on how to get your activation codes for Allplan IBD:

https://connect.allplan.com/en/faqid/20110912113530.html

Загрузка PDF  FAQ_EN_Hotletter_2019.pdf
Версия:  Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011  | Последнее изменение: 15.11.2017
1 user(s) found this FAQ helpful

Question:

How can I update cross-section catalogs or install country-specific cross-section catalogs in Allplan 2011 and later?



Answer:

To install and save cross-section catalogs in Allplan 2011 and later, select Tools -> Defaults -> Cross-Section Catalogs. A dialog box opens. You can find a folder symbol and a disk symbol at bottom left.

To install cross-section catalogs, use the folder symbol. Another dialog opens, where you can select the cross-section catalog file you want to install. Select the file to be installed and click "Open" to confirm. This installs the corresponding cross-section catalog, which you can now use in Allplan.
To install country-specific cross-section catalogs, select the "Ing" folder, which was created when you installed Allplan. You can find it in the Allplan installation path (e.g., c:\Nemetschek\Allplan 201x\New\Ing - more information on the Allplan installation path is provided below in the "Notes" section).
This folder includes the country-specify cross-section catalog files.

To save a custom cross-section catalog, use the disk symbol. Another dialog opens, where you can select any folder to save the cross-section catalogs currently used in Allplan.



Note:

To update cross-section catalogs, you may need administrator privileges. If necessary, log on as an administrator before you start the update.

To use the cross-section catalogs for a specific project only, set the path settings for the cross-section catalogs of this project to project before you install the cross-section catalogs. In Allplan, open the "File" menu and select "Open Project..." Click the corresponding project with the right mouse button. Select "Properties". A dialog box opens. In the "Path settings" area, set the "Bar and mesh cross-section catalogs" to "Project".

To determine the path where Allplan is installed, use the Services application and select Service -> Hotline Tools-> showcfg. The Services application window shows the path of the Allplan installation folder.

The following abbreviations are used for the country-specific cross-section catalogs in the file names (axyzqusr.txt):
aut Austria
bel Belgium
bra Brazil
bul Bulgaria
deu Germany
eng England
fra France
hol Holland
hrv Croatia
ita Italy
kor Korea
pol Poland
rum Romania
rus Russia
slk Slovakia
svn Slovenia
swi Switzerland
tch Czech Republic
ung Hungary
usa USA

Загрузка PDF  FAQ_EN_Updating_cross-section_catalogs_(Allplan_2011...
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018  | Последнее изменение: 12.11.2020
1 user(s) found this FAQ helpful

Question:

Why is Allplan running so slow?


Answer:

Check the following points:

1. Current version
Make sure you work with the current Allplan version.

  • Do the following or ask your system administrator to do this:
    Open Allplan and click the ‘?’ icon in the upper right-hand corner. Click ‘Update Allplan’.
    Select 'Find now'. If Allplan finds updates or hotfixes, download the installation packages.
  • Deactivate the virus scanner while your are installing updates or hotfixes. This might require administrator privileges. Contact your system administrator if you have problems.
  • Right-click the Allplan icon on the desktop. A shortcut menu opens.
    Select ‘Run as administrator’ and click ‘Yes’ to confirm the following message.
    As a result, Windows security settings do not block the installation.



2. System requirements:
Check the hardware and software required for your Allplan computer.

2.a)Download and run the system test.
Check the notes.
https://www.allplan.com/de/system/systemvoraussetzungen/

2.b)Check the Allplan system requirements:
https://www.allplan.com/de/system/systemvoraussetzungen/

2.c)You can find information about graphics cards at
https://connect.allplan.com/de/support/grafikkarten.html

2.d)You can find server operating systems you can use for the central file storage of Allplan at
https://connect.allplan.com/en/faqid/20140924094923.html


3. Hotline tools:
Start the Services application, open the ‘Service’ menu and select ‘Hotline Tools’. To save your settings, select the following tools.

- savestd: Saves user defaults.
- savereg: Saves CAD registry settings.

Start the Services application, open the ‘Service’ menu and select the following ‘Hotline Tools’:

- cleanup: Initializes the display.
- cleanstd: Resets CAD defaults.
- cleanreg: Resets CAD registry settings.

Check whether this has solved the problems.
If this is not so, restore the settings you just saved. To do this, start the Services application, open the ‘Service’ menu and select the following ‘Hotline Tools’:
- reststd: Restores saved user defaults.
- restreg: Restores CAD registry settings.


4. Color scheme selected in Allplan:
Start Allplan, open the ‘View’ menu, point to ‘Toolbars’ and select ‘Customize User Interface’. Open the ‘Customize’ tab and set ‘Color scheme and icon design’ to ‘Windows’.


5. Check the availability of all projects that are not online (if you use Workgroup Manager):
Start Allplan, open the ‘File’ menu and select ‘New Project, Open Project’. Deactivate ‘Check availability of all offline projects’.


6. Virus scanner
Check whether an anti-virus program is running in the background of the computer or server.
If so, reduce protection to "programs only".

Scanning "all files" can take a long time, considerably slowing down your computer when you switch between projects or exit the program.
You can exclude the Allplan installation folders from real-time scanning.When you start the Services application, you can see a list of the folders to be excluded.
You can find more information at
https://connect.allplan.com/en/faqid/20091126145752.html
Changes in the settings of the virus scanner only come into effect when you re-start the computer.


7. Aero desktop effects
Deactivate the Aero desktop effects of Windows.
To do this, open the Control Panel, select ‘Ease of Access’ and go to the ‘Make things on the screen easier to see’ area.
Select the ‘Turn off all unnecessary animations (when possible)’ option.


8. Name resolution on the network
If Allplan takes several minutes to start, name resolution on the network may not work.
To check this, do the following:
Right-click the Windows Start Button, select ‘Run’, type in ‘cmd’, click OK, type in ‘Nslookup’ and press ENTER.
Go to the line following the > character, type in the name of the Allplan data server and press ENTER.
The reply starts with the name and address of the server providing name resolution.
You can find the name and address of the Allplan data server in the second group.
If problems occur, contact your network administrator and ask him or her to configure name resolution correctly.


9. Speed of Allplan projects
Check whether some Allplan projects are slower than other Allplan projects.
Start with the empty project and check whether it is slow too.
After this, select any other Allplan project.

If it is only the current project that is slow, the problem may be caused by the data of the current project.
In this case, the data of this project must be analyzed in detail.
Contact technical support.


10. Network: checking out Allplan using Workgroup Manager
If you use Allplan with Workgroup Manager, you can check whether the problems are caused by the network. To do this, check out the workstation with the project in question and use the project on the local Allplan workstation.
You can find detailed information on checking out an Allplan workstation using Workgroup Manager in the
Services application. Open the ‘Help’ and select ‘Workgroup Manager’.

After you have checked out the workstation, Allplan no longer accesses the central file storage of the server.
If this has solved the problems, they are caused by the network. In this case, the network must be checked in detail.
Contact your network administrator and ask him or her to do this.

If the project is still slow, the problem may be caused by the data of the current project.
In this case, the data of this project must be analyzed in detail.
Contact technical support.


11. Log files and system information files
If all the points above do not solve the problems, technical support requires more system information about the computer running Allplan.

  • So, we would be grateful if you could send us a support request (Allplan Hotinfo with Allplan logging).
    To create a support request, start the Services application, open the ‘Service’ menu and select ‘Create support request (Hotinfo)’.
    Several dialog boxes open. Select ‘Technical Support Allplan’ and ‘Enquiry with Allplan logging’. Enter all the data required. Finally, click ‘Finish’.
    Another dialog box opens, prompting you to start Allplan. Click the ‘Start Allplan’ button.
    Allplan starts, logging all processes.
    Try to reproduce the problem as exactly as possible.
    Exit Allplan as soon as possible, reducing the data in the log file to a minimum.
    Then click ‘Next’ to generate the support request with the log file.
    You can find more information about Hotinfo at
    https://connect.allplan.com/en/faqid/20140528094911.html
  • To analyze the Windows system environment, we would ask you to send us the logs created by Windows Event Viewer of your computer.
    To start Windows Event Viewer, right-click the Windows Start Button, select ‘Run’ and type in ‘eventvwr.msc’.
    You can also type in ‘Event Viewer’ in the search box of Windows. This displays the link file to the Windows event logs.
    Using Event Viewer, create *.evtx files for the application log and the system log in the ‘Windows Logs’ area and for the ‘Administrative Events’ log in the ‘Custom Views’ area.


Please send us the files.

Загрузка PDF  FAQ_EN_Allplan_is_running_slow.pdf
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015  | Последнее изменение: 25.11.2019
4 user(s) found this FAQ helpful

Note:

You can help the technical support team to process your request by generating a support request with the Hotinfo program and sending it to us.

The generated support request will help to avoid unnecessary questions and delays, as it automatically contains all necessary information pertinent to the problem in question.


Procedure:

The Hotinfo program is installed along with Allplan; you can start it over the following ways:
1. Start -> All Programs -> Nemetschek -> Allplan [version number] -> Hotinfo [version number].
2. Allplan -> ? -> Generate support request (Hotinfo)
3. Allmenu/Services -> Service -> Create Support request (Hotinfo)


Select the team with whom you wish to communicate:
Choose the relevant entry, for example, Technical Support Allplan. The email address of the selected team is entered automatically.

Select the areas on which you have questions:
Please select the question that is pertinent to your support request.
You only need to select question 2 when Allplan support is requesting it from you.

01. General inquiry
02. Inquiry with Allplan logging

Note on question 02:
If you have selected question "02. Inquiry with Allplan logging", you can start Allplan straight form the Hotinfo after the questions.
This will generate and attach a log (trace).
Start Allplan by clicking on the button “Start Allplan”
Carefully reproduce the problem – for example, perform the steps that lead to the failure.
Then click "Next" to generate the support request with the trace.
You can click the "Take screenshot" button at any time while Allplan is running in logging mode. This way, you can quickly and easily save any error messages that may be displayed.

Enter your contact address:
Please enter your name, telephone number and email address
so that the technical support team can contact you.

Please describe the problem:
Describe the problem in detail (for example, include the exact wording of error messages).

Select the files you want to attach to the email:
You can include additional files with important information such as damaged drawing files, NID files or other files.

Note:
These files are only attached to the email when you send the Hotinfo by clicking “Finish” -> Option “Start email program…" or send it to us over File -> Send Message...".
See note further down.

Create the screenshots you want to attach to the email:
You can use the "New screenshot" button to take screenshots of the entire screen and send them as a file attachment to the Hotinfo.

Note:
These files are only attached to the email when you send the Hotinfo by clicking “Finish” -> Option “Start email program…" or send it to us over File -> Send Message...".
See note further down

Finish
Here you have the possibility over the pre-selected option "Start Email program..." to start your email program with the created Hotinfo, the generated files as a file attachment and the correct destination address. You only need to press &apos;Send&apos;.

Over option "Open Hotinfo file to save it..."you can open the support request, save, and send as an email attachment to support.de (please no spam) @ (please no spam) allplan.com, if no e-mail program is installed locally.
In this case, make sure to attach in addition to the support request all additional files also. Attach the "attached files" and "generated screenshots" independently as attachment to your email.

Загрузка PDF  FAQ_EN_Generating_a_support_request_using_Hotinfo.pd...
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014  | Последнее изменение: 30.09.2020
3 user(s) found this FAQ helpful

Question:

How can I check out a computer and continue to work as a normal CAD user with my usual settings and permissions?



Answer:

Install the "Microsoft Loopback Adapter" driver.
This driver is necessary so that network services are running on the computer all the time.
Go to Allplan Connect for a detailed description: https://connect.allplan.com/en/faqid/000162ae.html


Sign in as the Allplan administrator to the computer.


Step 1: add the computer to workgroup manager
You must add the computer to the workgroup so that you can store data (data server) on this computer. Do the following:

Create data folders:
Create a folder - for example, “Nemdata” - on the computer and share it (full control).
Create the “Allplan” subfolder in this folder. Create two subfolders - “usr” and “prj” - in the Allplan folder.
In this example: “...\Nemdata\Allplan\prj” and “...\Nemdata\Allplan\usr”

To share a folder for the Allplan file storage

  1. Start File Explorer on the computer that you want to use for file storage and switch to the folder that you want to share (in this example, the “Nemdata” folder).
  2. Right-click the folder that you want to share and select Give access to -> Specific peopleon the shortcut menu.
  3. Select Everyoneand click Share.


Add computer:

  1. Start the Services application as the workgroup administrator.
  2. Click and select Manage computers and projects.
  3. Click the Add any computer to Allplan workgroupicon and select the computer that you want to add.
  4. Select the “Allplan” subfolder under the share and click “OK” to confirm. This computer is now listed under workgroup server.


Note:If you have problems adding the computer to workgroup manager, read the following instructions:
https://connect.allplan.com/en/faqid/20200317162849.html



Step 2: define project owner
A user can only move a project if the user is the owner of this project.
The ownership of a project can only be changed by an Allplan administrator (or the owner of the project).
Allplan -> File -> ProjectPilot ->
Go to the “Projects” node, right-click the required project and click Propertieson the shortcut menu.
Define the owner.


Step 3: move projects
Sign in as the user who wants to check out the computer.
Select the Services application -> Workgroup Manager -> Manage computers and projects.
Click the main server and select the project that you want to move.
Drag the projects one after the other to the computer to be checked out.

Important note: You can take projects with you in several ways.

1. You move the project to the computer.
Move project: Drag the project to the destination computer, or open the shortcut menu of the project and click “Cut”. After this, open the shortcut menu of the destination computer and click “Paste”.
After you have checked in the computer, move the project back to the server so that it is available to all and included in backups again.

2. You copy projects. Click a project, select and hold the Ctrl key and drag the project to the destination computer. Or: Open the shortcut menu of the project and click “Copy”. After this, open the shortcut menu of the destination computer and click “Paste”.

You can continue in two ways: Lock the original project on the server to protect it from changes. Consequently, nobody in the office can work on this project, but it is still on the server. When you check in the computer again, you unlock the project on the server, delete the project and copy your copy back to the server if you have changed the project.
Alternatively, both projects remain active. Consequently, both the project copied and the original on the server can be worked on. In this case, however, you must adjust the data manually when you are back in the office by copying the changed drawing files of the projects by using ProjectPilot.




Step 4: check out the computer
Select the Services application -> Workgroup Manager -> Manage computers and projects.
Click your computer and then click Check outin the lower-right area.
Confirm the message that tells you that there are still user folders on the computer to be checked out.
Enter a comment and click OK. Users in the office see this comment when they try to access a project that is on the computer that is checked out.
Specify the parts of the office standard you want to copy to the computer and click OK to confirm.
The first time you check out the computer, you must copy the office standard once so that the entire STD folder is on this computer. This is no longer necessary when you check out the computer afterward because the contents of the STD folder do not change very often.


Conclusion:

You can now remove the computer from the network and work on your projects when you are out of the office. To make sure that the projects are not changed in the office in the meantime, the projects that are on the computer checked out are locked for the CAD users on the network. These users see the comment you entered when you checked out the computer.



Notes:


Загрузка PDF  FAQ_EN_Workgroup_Manager_checking_out_computer_and_w...
1 - 10 (32)
https://campus.allplan.com/ uses cookies  -  More information

Accept