Search Result

11 - 20 (21)
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 01.10.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

I have installed a Windows update. Now the license is no longer available.
When I start Allplan, I can see the following error message: "This license is no longer available" or "CmActLicense runtime system is not installed!" How can I restore the license?




Answer:

CodeMeter Control Center always saves the license to a container with the number Allplan GmbH 128-XXXXXXX on your computer.

Start CodeMeter Control Center:
Open the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.
Check the Licenses area to see whether there is the following container: Allplan GmbH 128-XXXXXXX.
The container must have a blue-green symbol and not a red symbol


Work through the following steps:

Step 1 Restart CodeMeterService
The local Windows service, which is used by licensing, must be running.

Restart this service:
CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.

Now check whether the Allplan GmbH 128-XXXXXXX container is displayed.

If this has solved your problem, all you need to do is exclude Codemeter from virus scans as described in the following document: https://connect.allplan.com/en/faqid/20151209133620.html

If the container is still not visible, go to step 2.


Step 2 Contact Support
Send the following information for analysis by e-mail to support.de@allplan.com:
If the container is not displayed, or is still displayed with a red symbol, please send us

1. a screenshot of the Codemeter Control Center. License tab.
Either found in the Windows Start menu via CodeMeter -> CodeMeter Control Center. Or enter Codemeter in the search bar on the start page.

2. the computer name from which the screenshot was taken. (can be found on the start page of the Allmenu->second line "Computer Name")

3. the license/workstation number, or the product key used

Download PDF  FAQ_EN_No_valid_license_available.pdf
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 24.10.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

The licensing service crashes regularly or does not start at all. Afterwards, no license is available. How can I solve this problem?



Answer:

Problems with the licensing service may have various causes.

If this problem occurs with specific clients only, you can find the cause on these clients. If this problem occurs with all clients, you can find the cause on the server.
Check the following points:


1. Virus scanner
The Codemeter Runtime Server service is running both on the client and on the server.

If the service is blocked on the client, this is often caused by the virus scanner.
However, this may also happen on the server.

If communication with the Wibu service is blocked, Allplan cannot find the license anymore. This is often caused by the virus scanner.
So, you need to exclude the "Codemeter" folder from virus scans. You can find this folder in the virus scanner in the following path: C:\Program files (X86)\Codemeteror C:\Programs (x86)\Codemeter. You can find the “Codemeter” folder in the following path:C:\Program files\Codemeteror C:\Programs\Codemeter.

Restart the service:

Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.

CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.



2. Update the CodeMeter program
Go to the Wibu website and install CodeMeter User Runtime Version for Windows (64-bit version).
You can find the installation program at https://www.wibu.com/de/anwendersoftware.html

Start the "CodeMeterRuntime.exe" file.
To do this, right-click this file and select
"Run as administrator".
Confirm all messages displayed and the defaults by clicking “Next”.
CodeMeter Control Center will be installed afterwards.



3. Other causes
Open the “C:\Windows\System32\drivers\” or “C:\Windows\SysNative\drivers\” folder and check whether this folder includes a file called "Multikey.sys". You must delete this file.
Before you delete this file, open Windows Device Manager (Control Panel) and check whether a driver called "Virtual USB Multikey X64" is installed.
If this driver is installed, uninstall it
before you delete the "Multikey.sys” file.
If this driver is not installed, delete the "Multikey.sys” file straightaway.

Note:
Sometimes, the system uses the "Multikey.sys” file in the c:\windows\system32\drivers\ folder to emulate a dongle.
This file is blacklisted by Wibu, as it interferes with the Wibu license system.

Sometimes, you can even find the "Virtual USB Multikey x64" device driver when you open Windows Device Manager.
If this driver exists, the "Multikey.sys” file will also exist.



4. Windows
The license server is based on .Net Framework. Allplan uses .NET 4.6. (Allplan 2019 and later will use .NET 4.7). Like any other Windows service, the Codemeter Windows service running on the license server depends on Windows components such as WMI. WMI depends on RPC, and RPC depends on COM distribution.

There may be a bug in Net. Framework of the operating system.
Fixing Net. Framework may solve the problem.

Check Windows Event Viewer and system information for .Net or WMI errors.
.Net may not be installed correctly,
Control Panel -> Administrative Tools -> Event Viewer -> Windows Logs
Check the application, installation and system.
Windows Event Viewer -> Windows Logs -> Application may include an application error in Allplan licensing. This error may be connected with .Net Framework.
Event ID = 1026 This ID indicates an error which you may fix by repairing the installation of .Net Framework.

Fixing Net. Framework may solve the problem.
Go to the Microsoft Support website at https://support.microsoft.com/de-de/help/2698555/microsoft-.net-framework-repair-tool-is-available.
There you can find a repair tool for fixing errors in .Net Framework.


Check Windows Event Viewer and system information for .Net or WMI errors.
.Net may not be installed correctly,
Control Panel -> Administrative Tools -> Event Viewer -> Windows Logs
Check the application, installation and system.




Note:
Do you have a second server? Test the license server on this sever. Install the license server on this server and activate the license there. Use the description at
https://connect.allplan.com/en/faqid/20150618134224.html
Has this solved the problems?

Download PDF  FAQ_EN_Licensing_service_is_not_running.pdf
Version:  Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 13.05.2020
1 user(s) found this FAQ helpful

Question:

The windows for options and the window for IFC import and export are closed immediately when opened. How can this issue be solved?



Answer:


1. HP computer

If you are using an HP (Hewlett-Packard) computer, please take these steps. Otherwise proceed to number 2.

Check whether the security software "HP ProtectTools" is installed on this computer. If yes, then uninstall "HP ProtectTools". This software suite consists of several progams. In most cases, these programs are:

  • HP ProtectTools Device Access Manager
  • Embedded Security for HP
  • Face Recognition for HP ProtectTools
  • File Sanitizer For HP ProtectTools
  • Privacy Manager for HP ProtectTools
  • Theft Recovery
  • Drive Encryption for HP ProtectTools
  • HP ProtectTools Security Manager



It is possible that more or less HP software than the listed is installed. When you uninstall the "HP ProtectTools Security Manager", no other dependent software should be listed during uninstallation.

If there is dependent software listed during uninstallation, please uninstall these programs first. As the last step, "HP ProtectTools Security Manager" should be uninstalled.

An example message, listing dependent software which is still installed:




Important notice: Please restart the computer to complete uninstalling the software.




2. Dell computer

If you are using a Dell computer, please take these steps. Otherwise contact the Allplan support.

Check whether the security software "Dell Data Protection" is installed on this computer. If yes, then uninstall "Dell Data Protection". This software suite consists of several progams. In most cases, these programs are:

  • Dell Data Protection | Security Tools Authentication
  • Dell Data Protection | Security Tools


It is possible that more or less Dell software than the listed is installed. When you uninstall the "Dell Data Protection", no other dependent software should be listed during uninstallation.

If there is dependent software listed during uninstallation, please uninstall these programs first. As the last step, "Dell Data Protection" should be uninstalled.

An example message, listing dependent software which is still installed:




Important notice: Please restart the computer to complete uninstalling the software.




Notes:

HP ProtectTools Security Suite was developed by McAfee in cooperation with HP. It is pre-installed on most HP business notebooks and on some HP desktop computers.

HP ProtectTools are using Full Volume Encryption (FVE) by McAfee Safeboot, which changes the Win32 API behaviour. This causes problems in Allplan.

Also Dell is using similar mechanisms for the Dell Data Protection Suite. They have the same influence on Allplan.

Please note that these programs in either case have negative effects on stability and functionality of Allplan, even if you might not notice it (example: working options and IFC windows in different Allplan version).


Download PDF  FAQ_EN_Options_window_IFC_window_closed_immediately_...
Version:  Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011 / Allplan 2009  | Last modified: 22.01.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How can I remove NemSLock completely from a computer?



Answer:

Do the following:

  1. Uninstall Softlock 2006 by clicking Start -> Control Panel -> Programs and Features.

  2. Select "Nemetschek SoftLock 2006" and then click "Uninstall/Change". Select "Remove" -> Next -> Yes.
  3. Extract the "NSLFixer2006.zip" file attached and copy it to any folder on your computer. If your email provider or firewall software has blocked this file, you can also download it from our webdrive. Use this link:

    https://webdrive.allplan.com/index.php/s/4LrjrymoxESzC6p

    The tool "NSLFixer2006.exe" is under Allgemein/Nemslock

    (click on the right hand side next to file size on the three dots and chose 'herunterladen')

  4. Start NSLFixer2006.exe by double-clicking it.
    Important note:
    If you are running Windows Vista or a newer operating system, click the program with the right mouse button and select "Run as administrator". Confirm the following message.
  5. Create the key by clicking "Generate/Enter a key" (1).

  6. Select the line to the right of "Generate/Enter a key" (2), "1F02E74917D3F6E7348C1F02E74917D35E2599A254864A233C549A25ADD2EDFD", for example, and press "Ctrl+C". Paste this key into an email and send it to "support.de@allplan.com".
  7. We will send you another key. Please copy this key to the second line (3). If you need to restart the program, paste the key you created into the first line (see step 3, do not click "Generate/Enter a key" again!). Then click "Validate twin key" (4). After you have done this, you should see the following message: "System cleaned. Reinstall NemSLock".
  8. Update your current Allplan version. Use the temporary license file ("psd" can be found in its file name). You can also find your current temporary licenses at www.connect.allplan.com. Go to "Profile -> License administration".
    Students should use the Allplan Setup program which they can download from Allplan Campus (http://www.allplan-campus.com -> log on -> select "Software" at the top -> download Allplan). Use the trial license provided by Setup.



After this, request a new license by sending a new registration request (Services application -> Utilities -> License -> License Manager). Select the license entry for your seat and click "Request license".
If you work with a license server, reconnect the client with the server.

Download PDF  FAQ_EN_Removing_NemSLock_completely.pdf Download NSLFixer2006_EN.zip
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017  | Last modified: 24.10.2019
1 user(s) found this FAQ helpful

Question:

How can I give individual users the right to see and select specific seats on the license server? And how can I deny users this right?
Sometimes, it may be necessary that a specific user does not see the seat with, for example, the terrain option so that this user cannot use this seat inadvertently.


Answer:

Using WebAdmin, you can give users rights for specific seats on the license server.
Please note the following points:

1. Before you start, check that at least CodeMeter Version 6.50 is installed on the license server.
Start CodeMeter Control Centeron the server.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen. Enter Codemeter and press ENTER. Select Help -> About to see which version of CodeMeter is installed. If the version displayed is older than version 6.50, you must install the latest version of CodeMeter Control Center. Go to the following website
and download the CodeMeter User Runtime for Windowsprogram.

https://www.wibu.com/de/anwendersoftware.html

2. Open WebAdmin. Start CodeMeter Control Centeron the server again.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen, enter Codemeter and press ENTER. A dialog box opens. Click WebAdminat bottom right.

Or
Enter Localhost:22350in the address bar of your browser.

3. Go to "Configuration -> Server -> License Access Permissions".
Select Mode: Advanced.

4. Go to "Advanced Mode Configuration -> Specific access rules -> Add Firm Code"and select "6000100 - Allplan GmbH". Click Add. "Specific access rules"now inlcude "6000100 - Allplan GmbH".





5. Click "Add Product Code"to select the seat for which you want to define access rights. However, this is only possible if the "Distinction based on Product Item Text" check box is selected.
The "Note" section below in this FAQ lists the abbreviations given at the end of each seat. These abbreviations represent the license contents.
Select the required seat and click "Add" again. Repeat these steps to assign more seats.





6. After having defined the product code, you can now assign an access rule.
By default, all users are allowedto access this seat.
Select the product code you just defined and click "Add new access rule".
Click "User" and enter the required user.
When you click in the field next to "User", you can see all available users with their domain names.
Select the user or enter the user manually. For example, enter DOMAINNAME\SSample and select the right you want to assign to this user by clicking "Allow" or "Deny".

If the default setting is "Allow", you can thus deny users access to the license. If the default setting is "Deny", you can thus allow users to access the license again.
You can add more rules. When you have configured all rules, click "Apply" to apply the changes.

7. You need to restart CodeMeter Service so that the changes take effect.
To do this, select CodeMeter Control Center -> Process -> Stop CodeMeterServiceand then click Restart CodeMeter Service.Before you restart the service, make sure all users have closed Allplan.


Information:

Client access can be defined by one of the following parameters: computer name, IPv4 subnet, user name or group name.
Enter the required parameter in the corresponding field. If you use an active directory, the program auto-completes entries in the "User" and "Group" fields.


Here comes a practical example:

Think about which setting is most useful to you. For example, you have two seats: seat 01 with 7 architecture licenses and seat 02 with 1 architecture license and 1 terrain license. Only two specific users should be able to use seat 02. If you want to deny all other users access to seat 02, you need to add seat 02 to specific access rules and define a rule for this seat 02. First, set the default setting to "Deny". Then, add these two users and select or "Allow" for these users. As a result, all other users can only see seat 01 and these two users can see seats 01 and 02.

However, if you want that these two users can only see seat 02, you need to add both seats to specific access rules and define a second rule for seat 01. Add these two users to this second role and select Deny for these two users. The default setting, which applies to all the other users, is still Allow. As a result, all other users can see seat 01 and these two users can only see seat 02.


Note:

The following abbreviations are used:

T Terrain
B Bamtec
W Workgroup
K Key Plan
M Bridge Modeler
L Cadastral plans for conduits
S Language option
V Visualization
A Architecture option
E Engineering option

Here are some examples:

Architecture:
"Allplan Architecture 2017”

Architecture + Terrain
"Allplan Architecture 2017 T"

Architecture + Bridge Modeler
"Allplan Architecture 2017 M"

Architecture + Terrain + Bridge Modeler
"Allplan Architecture 2017 TM"

Download PDF  FAQ_EN_License_server_-_assigning_access_rights_for_...
Version:  Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 17.12.2015
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How can I move NemSLock Server to a new server?



Answer:

Reinstalling NemSLock Server

  • Select one of the temporary license files for NemSLock server (for example, 1234567a_001_psd.nslsrv). These licenses are valid for 30 days. However, each license includes only one seat of each configuration purchased. The full number of seats purchased will be available to you as soon as you have installed the registered licenses (see below). If you purchased a configuration for one seat only, you will, of course, receive only one temporary license.
  • When you opt for the “Custom” setup type, you can choose between the following program features:
    Console
    You can use this program to administer NemSLock Server. The console can be installed on several workstations. This way, you can administer the server from a number of different locations. However, you can only connect one console to the server at any one time.
    Server
    The actual license server.
    Logviewer
    This tool analyzes the log files of NemSLock Server.
    User List Generator
    You can use this tool to create the users for NemSLock Server from a text file or based on a server.
    By default, Setup installs all these features.
  • If your license includes configurations for several seats, you need to install the additional temporary license files for NemSLock server after the installation (see below).


Transferring the user administration from the old server (if users are available)

  • You can find the user administration in the program folder of the license server. Copy the "users.mcf" file to the program folder of the new license server.
  • Stop the license server service on the new server before you copy the file. To do this, start the "stopService.bat" program, which is also in the program folder of the license server.
  • After copying, start the license server service again. To do this, use the "startService.bat" program.


Returning the registered licenses

  • Open NemSLock 2006 Server Console on the old server by clicking the icon on the desktop or Start -> (All) Programs -> NemSLock 2006 Server -> NemSLock 2006 Server Console.
  • Click "Stop server".
  • Click "Modules".
  • Click "Transfer license permanently".
  • Confirm the following dialog boxes. Click “Browse”.Windows Explorer starts and opens the folder with the hcws-format file. Now you can use all the options provided by Windows Explorer: for example, you can attach the file to an email, copy it to a computer with Internet access and so on.Send this file by email to register@nemetschek.de.
  • We will send you an email, confirming that we have received the licenses.
  • You always have to return all licenses.
  • After you have done this, they are only valid for two more days.


Registering the license(s) on the new server

  • Open NemSLock 2006 Server Console on the new license server.
  • Click "Modules" on the left.
  • Select the seat you want to register. If your license contains configurations for several seats, read the notes further down.
  • Click "Registration request (register.txt)".
  • Click "Edit".
  • Fill out all fields marked with an asterisk (*). Make sure you enter your email address correctly, because the registered license file will be sent to this address (and not to the address of the person who sent the registration request!). Click OK to confirm.
  • Click "Create registration request".Windows Explorer starts and opens the folder with the "register.txt" file. Now you can use all the options provided by Windows Explorer: for example, you can attach the file to an email, copy it to a computer with Internet access and so on.Send the registration request by email to register@nemetschek.de.


If your license includes configurations for several seats, you must send a separate registration request for each seat. You will then receive a registered license file for each seat. You must install each file.

How to install licenses

  • Open NemSLock 2006 Server Console.
  • Click "Stop server" on the left.
  • Click "Modules" on the left.
  • Click ”Browse” to navigate to the registered license file.
  • Click "Install license file".
  • After this, you can start the server again by clicking "Start server".


Configuring the clients

  • Now you need to change each client to the new license server.
  • Click Start -> (All) Programs -> Nemetschek -> Nemetschek SoftLock 2006 -> License Manager.
  • If the license server window is hidden, click "Configure NemSLock Server"at the bottom. It is a good idea to lock this window. All you need to do is click the drawing pin icon.
  • Enter the computer name or IP address of the license server in the empty box. Then click the "Update” icon to the right.
  • Now the user can select one of the seats provided. Click "Close" to complete the configuration. Now you can start Allplan.
  • After having successfully connected to the license server, clear the check boxes for the trial licenses in the area at the top.


Notes:

  • If a user selects several configurations for a seat and starts Allplan, the license server will provide the required licenses; in other words, starting Allplan once might require two licenses. Consequently, fewer licenses are available to other users.
  • 2014-1 and later: If the latest version of License Manager is installed (file version 1. 0. 26. 153 or later, see License Manager- Options- System), you can also select several licenses. If one of the selected licenses is currently being used by someone else, the program will automatically select the next available license.
  • Clients communicate with the server by TCP/IP via port 10977. So you need to configure the firewall accordingly.
  • The license server and the licenses are downward compatible; they can be used in conjunction with older Allplan versions.
Download PDF  FAQ_EN_Moving_NemSLock_Server_to_a_new_server.pdf ...
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017  | Last modified: 25.11.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

During installation I get an error message saying that SetupSchedTaks.exe does not work anymore.

When I try to start Allplan or the Services application, the following message appears:
The program cannot start; api-ms-win-crt-runtime-l1-1-0.dll is missing.



Answer:

This problem is caused by missing DLl files, which are required by Allplan. These DLL files usually come with the operating system. You will only see these messages if the operating system is not up-to-date. These messages are not caused by Allplan.
Instead, this problem is caused by the KB2999226 or KB2918614 (Universal CRT) Windows updates, which contain parts of Visual C++ Redistributable for Visual Studio 2015. Sometimes you cannot install these updates or they are defective.

If you have not yet installed these updates, install them now. In addition, install all available updates.

If you have already installed these two updates, try to install them again.
If the operating system is configured to automatically install Windows updates, some clients report errors during installation of the KB2918614 or KB29992226 package. These errors are caused by Windows, which blocks installation of files of the Visual Redistributable 2015 package. In this case, you must uninstall or delete the updates. After this, try to install the updates again.


If you cannot install the updates, do the following:
1. Deactivate automatic updates
2. Start -> Control Panel -> Windows Update -> change the settings -> never check for updates
3. Restart the computer
4. Download and install missing updates
5. Activate automatic Windows updates again


If you still cannot install the updates, run Windows diagnostics to check your system for update problems.

You can also install the updates manually. Use the following links:

KB2918614:
https://www.microsoft.com/de-DE/download/details.aspx?id=43759

KB2999226:
https://www.microsoft.com/de-de/download/details.aspx?id=49093


Try this if you still cannot install the updates:
https://www.smartftp.com/support/kb/the-program-cant-start-because-api-ms-win-crt-runtime-l1-1-0dll-is-missing-f2702.html



Note:

Regarding this error message, we cannot fix anything on the part of Allplan. These DLL files, which are required by Allplan, are an integral part of the Windows operating system.

Download PDF  FAQ_EN_Missing_api-ms-win-crt-runtime-l1-1-0dll_prev...
Version:  Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 30.11.2017 17:22
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How to install and run NemSLock Server?



Answer:

Before installing, check whether the package you received includes the following items:

  • Temporary licenses for NemSLock Server, e.g. 1234567a_001_psd.nslsrv
  • Temporary licenses for clients, e.g. 1234567a_001_psd_client.nslock



How to install NemSLock Server

  • Start the Setup program for NemSLock Server. You can find the latest Setup program on our FTP server:

ftp://nemhotline:ha37jvg8f@ftp.nemetschek.de/download/Allplan/Lizenzserver/2014/allplan2014-nemslock-lizenz.zip

  • Select one of the temporary license files for NemSLock Server. These licenses are valid for 30 days. However, each license includes only one seat of each configuration purchased. The full number of seats purchased will be available to you as soon as you have installed the registered licenses (see below). If you purchased a configuration for one seat only, you will, of course, receive only one temporary license.
  • When you opt for the “Custom” setup type, you can choose between the following program features:
    Console
    You can use this program to administer NemSLock Server. You can also install the console on more workstations so that you can administer the server from a number of different locations. However, you can only connect one console to the server at any one time.
    Server
    The actual license server.
    Logviewer
    This tool analyzes the log files of NemSLock Server.

By default, Setup installs all these features.
If you have several temporary licenses for NemSLock Server, use the server console to install the remaining licenses after the installation. The procedure is described in the section "How to install licenses".


How to register licenses

  • Open NemSLock 2006 Server Console by clicking the corresponding icon on the desktop or by selecting Start -> All Programs -> NemSLock 2006 Server -> NemSLock 2006 Server Console.
  • Click "Modules" on the left.
  • Select the seat you want to register. If your license includes configurations for several seats, you must send a separate registration request for each seat. You will then receive a registered license file for each seat. You must install each file.
  • Click the "Registration request (register.txt)" button.
  • Click "Edit".
  • You must fill out all fields marked with an asterisk (*). Make sure you enter your email address correctly, because the registered license file will be sent to this address (and not to the address of the person who sent the registration request!). Click OK to confirm.
  • Click "Create registration request". Windows Explorer opens and shows the register.txt file. If this window is closed, you can find this file in the program folder of NemSLock Server. If you installed the program to the path proposed, the path is:
    C:\Program Files (x86)\Nemetschek\NemSLock Server 2006\Programs\License
  • Now you can use all the options provided by Windows Explorer to copy the registration file to a computer with Internet access on the network. Alternatively, you can also use an USB stick. You can then email this file to us.
  • Send the email with the registration request to register@nemetschek.de



How to install licenses

  • Open NemSLock 2006 Server Console.
  • Click "Stop server" on the left.
  • Click "Modules" on the left.
  • Click "Browse" to navigate to the registered license file.
  • Click "Install license file".
  • After this, you can start the server again by clicking "Start server".



How to set up users (optional)

  • predefined user ALLis created automatically. If there is no other user, each user is given the privileges of the user ALL. By default, this user can use all licenses but cannot check out any licenses. By double-clicking the user, you can change the user's privileges.
  • predefined user ALLallows all users to use licenses. In order to do this, the users must be able to access the server. You do not need to create individual user profiles until you want to assign specific rights to individual users or limit access to selected users. predefined user ALL. If you want to work only with individual users, you should deactivate the predefined user ALL by revoking the user's right to use licenses.
  • predefined user ALL has administrator privileges unless another user is created and appointed as the administrator. As soon as you have appointed an administrator, ALL no longer has administrator privileges.
  • You can enter users in the “Users.mcf” file. predefined user ALL has administrator privileges again. In addition, each user can once again administer the license server using the console.
  • The administrator user is not a special user. If there are several administrator users, only one administrator user can start the console for this license server at any one time.
  • If you are setting up users without giving administrator privileges to anyone, the program will ask you whether you want to appoint yourself as the administrator.


You can also specify a domain (user authentication for Windows server). However, this is not mandatory. If you do not specify a domain, the program uses the Windows user name for each user.

The program writes the user accounts and the associated access rights as ASCII text to the users.mcf file.

You can find this file in the \Programs folder of the NemSLock Server installation. You cannot rename, delete or move this file. If the program can no longer connect to this file, you must exit NemSLock Server, restart it and enter all users again from scratch. predefined user ALLis retained.

Note:
Experienced administrators can use the PowerShell script NemGenUsers.ps1. This file is in the \Programs folder of the NemSLock Server installation or you can find it as an FAQ in Allplan Connect:

connect.allplan.com/en/faqid/20120907161911.html



How to install and configure clients

  • Use one of the nslock license files you received to install the clients. Do not use the trial license or the license server license. It is irrelevant which of the client licenses you use, as the actual license will come from the license server later.
  • You do not need to register the clients.
  • When switching from Hardlock to NemSLock (server), you need to update the client using a nslock license file.


After having installed the client, you need to switch to the license server:

  • Start -> (All) Programs -> Nemetschek -> Nemetschek SoftLock 2006 -> License Manager
  • If the license server window is not visible, select "Configure NemSLock Server" at the bottom. Lock this window. All you need to do is click the drawing pin icon.
  • Enter the computer name or IP address of the license server in the empty box. Then click the "Update” icon to the right.
  • Now the user can select one of the seats provided.
  • After having successfully connected to the license server, clear the check boxes for the trial licenses in the area at the top.
  • Click "Close" to complete the configuration. Now you can start Allplan.



Notes:

  • If a user selects several configurations for a seat and starts Allplan, the license server will provide the required licenses; in other words, starting Allplan once might require two licenses. Consequently, fewer licenses are available to other users.
  • 2014-1 and later: If the latest version of License Manager is installed (file version 1. 0. 26. 153 or later, see License Manager- Options- System), you can also select several licenses. If one of the selected licenses is currently being used by someone else, the program will automatically select the next available license.
  • Clients communicate with the server by TCP/IP via port 10977. So you need to configure the firewall accordingly.
  • The license server and the licenses are downward compatible; they can be used in conjunction with older Allplan versions.
Download PDF  FAQ_EN_Installing_and_configuring_NemSLock_Server.pd...
Version:  Allplan 2020 / Allplan 2019  | Last modified: 08.04.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

You may ask yourself on which occasions or user actions Allplan synchronizes drawing files and plans with the Bimplus Cloud in an Allplan Share project.


Answer:

The following cases apply to drawing files:


Case 1:
Drawing files in a share project are uploaded to the Bimplus cloud for synchronization if all three of the following conditions apply:

  • A change has occurred on the drawing files
  • The drawing files have been changed to gray or deselected
  • Open on a project-specific basis is closed


If other users have the drawing file which meets all the criteria in case one, grayed out (i.e. it is passively in the background), then after the first user has carried out all three steps, they will automatically receive a message informing them that there have been changes to the drawing file. They can then either display or reject these changes.
If the other users do not see this message, they should make sure that they are using the latest version of their Allplan installation and that the check mark is set in the options for
Options -> Desktop Environment -> Save/Load -> For changes in reference drawing files show message. If the check mark is not set, simply set it and restart Allplan.

Case two:
In Allplan, click on Allplan A in the top left-hand corner and select Save all -> all drawing files that have changes are synchronized.

In this case too, as in case 1, a message is sent to all users who have the drawing file, to which all the criteria from case 1 apply, in grey (i.e. passively in the background).

Case three:
Even if you simply open the function New project, Open Project, all drawing files that have been modified are synchronized

Case four:
When you call up the Layout Editor, all drawing files that have been changed are also synchronized



The following applies to plans:
If drawing file contents in the plan change, then the plan is NOT uploaded - no need . Plans are only uploaded if either something changes in the plan layout (move or delete a plan element in the plan, etc.) or, for example, the scale or drawing type of a plan element is changed. The upload then takes place automatically when you change the plan or leave the plan layout.




Note:

In Allplan version 2018, these notes also apply accordingly; only case 2 for drawing files does not work in this version.

Download PDF  FAQ_EN_When_do_Allplan_share_projects_synchronize_dr...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015  | Last modified: 16.10.2020
9 user(s) found this FAQ helpful

Information:

Quality reporter notified us of a crash. In analyzing the data, we found that you can improve the stability of your Allplan installation by installing the current graphics card driver.

You can find the current driver on the homepage of the graphics card manufacturer.
http://www.amd.com/de Support & Driver -> Download driver
http://www.nvidia.de Download driver

Use the driver on the homepage of the manufacturer. Do not use the driver provided by Windows Update.

Notes for notebook users:
It is essential that you install the graphics card drivers provided by the notebook manufacturer! You can find the current drivers on the homepage of the manufacturer.


Notes:

  • If the program still crashes after you have installed the latest graphics card driver, change the graphics mode from OpenGL to GDI+ in Allplan.

    Allplan 2012-1 and later:
    Start Allplan and select Tools -> Options.
    Select Desktop environment -> Display > Hardware acceleration - graphics area: switch off the "Use OpenGL for all viewports" option. Restart Allplan.

    From Allplan 2011-1 to Allplan 2012-0-2:
    Start the Services application.
    Service -> Hotline Tools -> draw -> OK
    On = OpenGL mode
    Off = GDI+ mode
  • You can find information on graphics cards at
    https://www.allplan.com/services/cad-software-support/grafikkarten.html
Download PDF  FAQ_EN_Quality_Reporter_-_graphics_card_driver_cause...
11 - 20 (21)