Search Result

21 - 30 (73)
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 30.09.2020
1 user(s) found this FAQ helpful

Question:

I have used the "Check out" tool to check out the computer from the network and remove the network connection.
Why is Workgroup Manager no longer working?



Answer:

Windows disables network functionality as soon as you remove the network connection (unplug the network cable).
Running Allplan, however, requires specific network protocols (even if the computer is checked out).



Solution:

To make sure that the operating system's network functionality is not interrupted, you can install a virtual network interface card.
Microsoft provides a driver for this (loopback adapter).

How to install:

Windows 8/10:
Right-click the Windows Start button -> select "Run".
Type in "hdwwiz" in the search field. Right-click the program found -> select "Run as admin".
Click Next -> select the required hardware manually in a list and install it -> click "Next".
Select "Network adapter" in the list -> click "Next".
Select "Microsoft" in the list on the left -> "Microsoft loopback adapter for KM TEST" is presented for selection on the right -> click "Next" -> click "Next".

Windows 7:
Click the Windows Start button -> type in "hdwwiz" in the search field. Right-click the program found -> select "Run as administrator".
Click Next -> select the required hardware manually in a list and install it -> click "Next".
Select "Network adapter" in the list -> click "Next".
Select "Microsoft" in the list on the left -> "Microsoft loopback adapter" is presented for selection on the right -> click "Next" -> click "Next".

Windows Vista:
Start the "Hardware Wizard" by selecting
Start -> Control Panel -> Hardware and clicking Continue -> Next.
Select "Install the hardware that I manually select from a list (advanced)" in the box and choose "Network adapter" in the list that follows.
This selects and installs the "Microsoft loopback adapter".

Download PDF  FAQ_EN_Installing_loopback_adapter_for_a_stand-alone...
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 25.11.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

What can I do if Allplan does not start?


Answer:


Work through the following steps:

Step 1 - run as administrator
Start Allplan with the ‘Run as administrator’ option.
To do this, right-click the Allplan icon and click ‘Run as administrator’.
If Allplan does not start, go to step 2.

Step 2 - cleanup
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanup -> OK
If Allplan does not start, go to step 3.

Step 3 - cleanstd
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanstd: reset CAD defaults -> OK -> OK -> Yes -> OK
If Allplan does not start, restore the settings:
Services application -> Service -> Hotline Tools -> laststd: restore the last settings -> OK -> OK -> Yes -> OK
Go to step 4.

Step 4 - cleanreg
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanreg: reset CAD registry settings -> OK -> OK -> Yes -> OK
If Allplan does not start, restore the registry settings:
Services application -> Service -> Hotline Tools -> lastreg:restore most recent CAD registry settings -> OK -> OK -> Yes -> OK
Go to step 5.

Step 5 (Allplan 2016 and later)
Restart the Wibu service:
Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.

CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.

If Allplan does not start, go to step 6.

Step 6 (Allplan 2016 and later)
Go to the Wibu website and install CodeMeter User Runtime Version for Windows (64-bit version).
You can find the installation program at https://www.wibu.com/de/anwendersoftware.htmlor on the Nemetschek FTP server ftp://nemhotline:ha37jvg8f@ftp.nemetschek.deat download/General/Wibu/CodemeterRuntime.exe

Start the ‘CodeMeterRuntime.exe’ file.
To do this, right-click this file and select
‘Run as administrator’.
Confirm all messages displayed and the defaults by clicking ‘Next’.
CodeMeter Control Center will be installed afterwards.
If Allplan does not start, go to step 7.

Step 7 - contact Technical Support
Send the following information by email to support.de@allplan.com:

  1. An exact description of the last step before the error or crash occurred.
  2. The error message itself (as a screenshot). To find out how to take a screenshot, look at
    https://connect.allplan.com/en/faqid/0001cb36.html
  3. A support request (Hotinfo) with question 01. To find out how to create a support request, look at
    https://connect.allplan.com/en/faqid/20140528094911.html
  4. The 'Allplan.out' log file. To find out how to create a support request, look at
    https://connect.allplan.com/en/faqid/0001a27a.html
  5. Allplan 2016 and later -> a screenshot of the Wibu Control Center. To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.


We will contact you.

Download PDF  FAQ_EN_Allplan_does_not_start.pdf
Version:  Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 25.06.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

What can I do if Allplan starts as a viewer only and I have to install a new hardlock driver?



Answer:

Install the latest hardlock driver.

How to install:

Use the following link to download the driver:

https://webdrive.allplan.com/s/4LrjrymoxESzC6p

The driver for Windows 7 and 8.1 is in the following folder.
/Download/Allgemein/Dongle/

If you are using Windows 10 then use the driver under the folder:
/Download/Allgemein/Dongle/Win10

Extract and save the 'haspdinst.exe' file to any folder, for example, c:\drivers. Then open the command prompt:
Right-click Start (Windows button) -> Command Prompt (Admin)
Switch to the folder where you saved the file. To do this, type in "cd c:\drivers".

To remove the old drivers, enter the following command:
haspdinst -fremove
Next, install the new driver:
haspdinst -install


Note:

If you use a parallel hardlock, read the following instructions:
https://connect.allplan.com/en/faqid/20121011092418.html

Download PDF  FAQ_EN_Installing_a_new_hardlock_driver.pdf
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 12.11.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

Which graphics cards are recommended for Allplan?



Answer:


Follow this link to see a list of the AMD/ATI & NVidia graphics cards manufacturers that are CERTIFIED FOR ALLPLAN.
We have tested the OpenGL functionality and the animation performance of various Allplan modules with specially prepared data with each of the cards available.
https://www.allplan.com/services/cad-software-support/grafikkarten.html

The tested drivers can be found on the homepage of the individual manufacturer. The driver versions that were used in the tests are included in the tables so that you can compare the data. However, we strongly recommend that you always installthe current driver of the manufacturer.

It is a good idea to check your system using the system tool you can find on our homepage:
https://www.allplan.com/services/cad-software-support/downloads.html



Additional information:

Allplan 2011 was revised completely for accelerated graphical representation.
To guarantee full performance support for Allplan 2011 and later, please check that your graphics cards meet the hardware requirements for DirectX 10 & OpenGL 2.0 (chip-based). In addition, you need to install the current drivers. Allplan will automatically switch to the conventional drawing method when it starts and finds old graphics cards that do not meet the requirements stated above.

For more information on graphics card specifications, go to

http://en.wikipedia.org/wiki/Comparison_of_AMD_graphics_processing_units
http://en.wikipedia.org/wiki/Comparison_of_NVIDIA_graphics_processing_units#Quadro)



Note:

We kindly ask you to understand that products of other manufacturers that are not mentioned have not been tested and therefore cannot be recommended.

Download PDF  FAQ_EN_Recommended_graphics_cards_for_Allplan.pdf ...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014  | Last modified: 27.10.2020
1 user(s) found this FAQ helpful

Question:

I can neither check in nor check out the computer.
When I try to check in the computer, the following error message appears: “The registry entries are not correct!” How can I correct this error?


Answer:

There is a hidden file on the server. This file causes the problem, which is probably related to user rights or user account control.

You have to change the settings directly on the server, that is so say, you have to use the folder options to show all hidden folders and files.

1. Open the central file storage folder on the server. There is a subordinate folder called
NET. This folder contains the computer_name.out file. Here, computer_name is the name of the computer that is checked out.
Delete this file.

2. Open the shared folder (for example, C:\Nemdata\Allplan) on the computer that is checked out.
Allplan 2015 and earlier: Delete the Net.ChkOutfolder.
Allplan 2016 and later: Delete the NETfolder.

Now the computer is checked in again. Consequently, you can move projects to this computer
or check it out once more.


Note:

If the computer or the projects are still red, you have to fix the projects.

To fix the projects:
Services application -> Workgroup Manager -> Administer projects and computers

Do the following:

Ctrl + right-click computer
-> can be checked in
Ctrl + right-click project-> can be unlocked

Repeat this step to unlock every project on the computer.
When you have finished, close the dialog box and open it again to update it.
Now everything should be correct.

Download PDF  FAQ_EN_Workgroup_Manager_Problems_when_checking_in_o...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 01.10.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

Does Allplan create backup files (*.bak)?
How can I use these files?



Answer:

Allplan creates backup files when you do the following:

  1. Copy, Move Elements between Documents …
    Allplan creates a backup file of the destination drawing file or layout.
  2. Deleting drawing files and layoutsin the "Open on a project-specific basis" dialog box
    If you have selected "Create backup copies of drawing files", Allplan creates a backup file of the drawing file or layout.
  3. Importing data to drawing files
    If you have selected "Create backup copies of drawing files", Allplan creates a backup file of the drawing file.


Note on points 2 and 3:

To select the "Create backup copies of drawing files" option, click
Tools -> Options -> Desktop environment -> Save/load area (until V2009 Global Options -> Miscellaneous -> Autosave, Backup)->Create backup copies of drawing files.


Restoring:

If need be, you can restore the original drawing file or layout.
Make a note of the drawing file number or layout number and determine the corresponding project folder as follows:
Services application -> Service -> Hotline Tools -> wopro

Open this folder in Windows Explorer.

Rename the corresponding drawing file "tb000001.ndw" "tb000001.ndw.old" or the corresponding layout "pb000001.000" "pb000001.000.old.", for example.
Delete the bak extension from the corresponding bak file.

Example 1:

You have inadvertently copied the wrong elements to drawing file 4711.
1st step: exit the project in Allplan.
2nd step: delete file tb004711.ndw or rename it tb004711.ndw.old.
3rd step: find file tb004711.ndw.bak and rename it tb004711.ndw.

Example 2:

You have inadvertently copied the wrong elements to layout 815.
1st step: exit the project in Allplan.
2nd step: delete file pb000815.000 or rename it pb000815.000.old.
3rd step: find file pb000815.000.bak and rename it pb000815.000.



Note:

These backup files can considerably increase the volume of data to be backed up. So it is a good idea to delete the .bak files you no longer require before you start backing up data. To delete the .bak files, you can select the Services application and click Utilities -> Delete temporary files.

You can also find this information in the help for Allplan. Please refer to the topic "Using bak files".

Download PDF  FAQ_EN_Using_bak_files.pdf
Version:  Allplan 2020 / Allplan 2019 / Allplan 2017 / Allplan 2016 / Allplan 2015  | Last modified: 12.06.2020
1 user(s) found this FAQ helpful

Question:

What can I do if Allplan no longer starts after I have upgraded and the following messages appear?
Allplan
Stop

...

After this, Quality Reporter displays an error report.



Answer:

Exit Allplan on all workstations and do the following:
Open the Services application and make a note of the path to the 'central file storage folder', which is displayed in the Services application window.
In addition, check whether the workgroup manager line is followed by 'Yes' or 'No'.

Open the central file storage folder in Windows Explorer.

If the workgroup manager line is followed by
'Yes', open the NET subfolder.
'No', open the PRJ subfolder.

Find the 'project.dat' or 'project.Dat.xm' file in the NET or PRJ folder and rename it 'project-old.dat'.

After this, do the following:
Services application -> Service -> Hotline Tools -> reorg -> OK -> Restore project management file -> OK
The program creates a new, correct project management file and you can start Allplan again.



Note:

If you come across error messages while doing this, please email the following information to support@allplan.com:

  1. Describe exactly what you did before the error or crash occurred.
  2. The error message itself (as a screenshot).
  3. The log file (trace).
    https://connect.allplan.com/en/faqid/0001a27a.html
  4. A Hotinfo support request with question 01.
    https://connect.allplan.com/en/faqid/20130823123806.html
Download PDF  FAQ_EN_Allplan_does_not_start_after_upgrade_Stop_mes...
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 25.11.2019
3 user(s) found this FAQ helpful

Question:

How can I restore a lost building structure or layout structure?



Answer:

To restore a lost or corrupt building structure or layout structure, you can do the following:

  • Close Allplan.
  • Open Windows Explorer, go to the central file storage folder of Allplan and open the "Prj"folder. Open the corresponding project folder and the "BIM" subfolder.

    Note:
    If the "Same folder name as project name" option is not selected for the project, a number is used for the folder name in the "Prj"folder. In this case, open the Services applicationand select the woprohotline tool (Services application -> Service -> Hotline Tools -> wopro). Select the corresponding project by double-clicking its name. An information dialog box shows the folder and file name of the project.
  • You can find an XML file for each structure in the BIM subfolder.


Building structure:
Allplan_BIM_BuildingStructure.xml

Objects derived from building structure:
Allplan_BIM_Views.xml

Plane model:
Allplan_BIM_LevMo_"name of model".xml

Layout structure:
Allplan_BIM_LayoutStructure.xml

  • To restore the building structure from a backup, rename the existing file "Allplan_BIM_BuildingStructure.xml" "Allplan_BIM_BuildingStructure.xml.old", for example.
  • Switch to the "Backup"folder, which you can also find in the"BIM"folder.
  • Select the most recent file that had been created beforethe building structure was deleted, for example, "Allplan_BIM_BuildingStructure.xml.27.5.2008--10-32-21.bak". The characters in bold indicate the date and time of the backup. Copy this file to the "BIM"folder.
  • Rename this file by deleting the characters after ".xml". Now the file name is "Allplan_BIM_BuildingStructure.xml".
  • Restart Allplan. The last version of the building structure is displayed in the "Open on a project-specific basis"dialog box again.




Note:

Using Allplan 2009-2 and later, you can restore the layout structure from a *.bak file straight from the "Open on a project-specific basis: layouts"dialog box.

  • Right-click the topmost structural level in the layout structure (project name) and select Load layout structure favoriteon the shortcut menu.
  • Open the last version of the Allplan_BIM_LayoutStructure.xml file in the backup folder mentioned above.


If the *.bak files are not displayed, please follow the steps described above.

Download PDF  FAQ_EN_Restoring_building_structure_layout_structure...
Version:  Allplan 2019 / Allplan 2018  | Last modified: 05.05.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How can I set up Allplan Share? What are the requirements?


Answer:

1)System requirementsfor Allplan Share

Software required

Allplan Version 2018 or higher

Network infrastructure required

Minimum requirements:

A 20-Mbit/s Internet connection for downloading and uploading data

Recommended setup:

At least a 50-Mbit/s Internet connection for downloading and uploading data

2) Licensing

You have two options to buy the Allplan Share option.

1. You can visit the Allplan Shop at ‘shop.allplan.com’.

Allplan Options -> Allplan Share

a. Specify how many licenses you want to buy and add the Allplan Share option to the cart.

b. Follow the instructions displayed and buy the Allplan Share option.

After you have bought the Allplan Share option, the licenses will be assigned to your Bimplus team. You can manage these licenses using ‘My Account’ - ‘Subscriptions and Users’.

2. You can contact the Allplan sales partner in your area.

3) Assigning licenses

Regardless of how you buy the Allplan Share option, you can manage the Allplan Share licenses in the Allplan Shop. Go to the ‘Subscriptions and Users’ area. As an alternative, you can also manage the licenses on the Bimplus portal. Here, go to the ‘Team members’ area.

Allplan Shop - ‘Subscriptions and Users’

1. Log in to the Allplan Shop and open ‘My Account’.

2. Click ‘Subscriptions and Users’ to see your licenses.

3. Select the Allplan Share option on the tab.

4. You can assign one or more Allplan Share licenses to team members. To do this, select the user in the list and assign the license by selecting the check box. You can remove the license at any time by clearing the check box.

If the list does not include the user to whom you want to assign a license, click ‘Invite new Bimplus team member’, enter the email address of the new team member and select a role.

As soon as the new team member has accepted the invitation, you can find this person in the list.

4) Using Allplan Share

To use the Allplan Share option, you require Allplan 2018. The Workgroup Manager option is not necessary.

Starting a project

You have three options to start an Allplan Share project:

1. You can create a new project and save it on Bimplus by setting the location to BIMPLUS. To create a Bimplus project with Allplan Share content, you require ‘Bimplus team owner’ or ‘Bimplus team admin’ privileges.

2. You can copy an existing Allplan project to Bimplus by selecting ‘Copy to’. You can then share this project with other project partners. This does not affect the source project.

3. You can move an existing Allplan project to Bimplus by selecting ‘Move to’. This moves the source project to Bimplus. As a result, this project is no longer available on the local computer or local network.

5) Managing users and assigning users to the project

Allplan Share is a cloud-based solution. Therefore, Allplan Share uses the Bimplus user management for project collaboration. As a result, Allplan Share is independent of local user management systems like Workgroup Manager.

After you have copied or moved an existing Allplan project to Bimplus, you must reassign the users to this project. Otherwise, they cannot access this project.

To define the project members, use the Bimplus project administration. In addition, you must invite new project members to the Bimplus project.

If these Bimplus project members are to use the Allplan Share option too, you must assign an Allplan Share license to each member in advance (as described in ‘3) Assigning licenses’).


Download PDF  FAQ_EN_Allplan_Share.pdf
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 12.11.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

Why does ProjectPilot open with the following error message:
"Unable to create ProjectPilot control. Is the registry correct?"



Answer:

The reason for this is usually an "external path" that no longer exists. When you start ProjectPilot,
the program tries to access the "external path", which is stored in the Windows Registry.
If this path no longer exists, you will see the above error message.

To correct this error, please do the following:

  • Services application
  • Service menu
  • Windows Explorer - CAD program folder
  • The path to the "User folder" is displayed in the window of the Services application. Open it in Windows Explorer.
  • Find the "extern.cfg"file in this user folder and delete this file.


Now try to start ProjectPilotagain. If the problem still occurs, please do the following:

Start the services application -> Service -> Windows Explorer -> CAD program folder.
Open the "PRG" folder.
Find the following file: "NemProjectPilot10.exe"
Right-click this file -> select "Run as administrator" on the shortcut menu.
ProjectPilot should now start.

Try to start ProjectPilotstraight from Allplan. If the problem is still not solved, please do the following:

  • Services application
  • Service menu
  • Windows Explorer - CAD program folder
  • The Allplan program folder opens.
  • Rename the "PRG" subfolder "PRG_OLD".
  • Start installing the program from the current Allplan DVD.
  • Select "Update installation".
  • Select "Current license file".
  • Set the setup type to "Minimum".


After installation try to start ProjectPilotagain.

Download PDF  FAQ_EN_Error_message_when_ProjectPilot_starts_Unable...