Question:

What are the reasons why I cannot modify the format properties (pen thickness, color, ...) of elements in a DWG/DXF file I have just imported?



Answer:

There are four reasons why these elements cannot be modified.

1st -the elements are smart symbols:

  • To retain the smart symbols but still be able to modify the elements, select Modify -> Bonus Tools -> Smart Symbols -> Modify Smart Symbol(until V2006: Modify -> Bonus Tools -> Smart Symbols -> Modify Display Parameters) and click the relevant element. Now you can modify it (using Modify Format Properties, for example). For more detailed information on how to modify smart symbols, please contact us.
  • If you do not want to retain the smart symbol, you can also resolve it: Modify -> Bonus Tools -> Smart Symbols -> Unlink Smart Symbol, select the smart symbol(s) you want to resolve and click the right mouse button to confirm.
  • To resolve the smart symbols during import, select the file to be imported, click the"Options..."button,open the "Advanced Settings" tab (until Allplan 2008 "Advanced Transfer Settings")and select the"Smart symbol"check box in the"Explode elements" area. To confirm the dialog box, click OKand open the file.


2nd - theelements are composite elements:

  • To explode a composite element, select Modify -> Advanced Draft -> Explode Composite Element. Select the composite element(s).
  • To resolve the composite elements during import, select the file to be imported, click the "Options..." button, open the"Advanced Settings" tab" (until Allplan 2008: "Advanced Transfer Settings") andselect the "Composite elements"check box in the"Explode compounds" area. To confirm the dialog box, click OKand open the file.


3rd - the elements are on frozen layers:

  • To modify these elements, you first have to set the corresponding layers to modifiable. Open the layer selection by clickingFormat -> Select, Set Layers.On theSelect Layer/Visibilitytab, set all the layers to modifiable.


4th - the elements have the "from layer" format property:

  • To find this out, click an element with the right mouse button and selectFormat Propertieson the shortcut menu: pen thickness, line type or line color is not available for elements with the "from layer" format property.
  • To modify the format properties of the layer, select Format -> Select, Set Layers and open the'Format Definition' tab. Check that the''Match from layer based on line style, pen, line, color assigned (fixed setting)"optionis selected in the"Layers' format properties" area. Next, select the layer on which the element resides and change its format properties.
  • To remove this property, clickEdit -> Modify Format Properties, select the"Change 'from layer' for pen, line and color" option(pen thickness, line type and line color must not be selected) and select the elements.
  • To resolve the "from layer" property during import, select the file to be imported, click the "Options..." button, open the"Advanced Settings" tab" (until Allplan 2008: "Advanced Transfer Settings") andselect the "From layer"check box in the"Explode compounds" area. To confirm the dialog box, click OKand open the file.




Note:

If you have any further questions regarding data exchange, this topic is described in detail in the online Help. All you need to do is press the F1 key. Open the Index tab and selectInterfaces.

Download PDF  FAQ_EN_Elements_cannot_be_modified_after_import.pdf ...
Version:  Allplan 2013 / Allplan 2012 / Allplan 2011 / Allplan 2009  | Last modified: 30.11.2017
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How can I output a test plot with different data types used in Allplan?



Solution:

Allplan comes with drawing files containing test data that can be used for this purpose.

If necessary, create a new project and copy the drawing files with the test data to this new project.

Open ProjectPilot: Allplan -> File -> ProjectPilot - Admin.

Set the external path to the '..\New\Testplot' folder, which is a subfolder of the local Allplan program folder.
Click 'External path' with the right mouse button and, on the shortcut menu, choose 'Select external path'.
Select the '..\New\Testplot' folder, which is a subfolder of the local Allplan program folder: c:\Programs\Nemetschek\Allplan\New\Testplot, for example.

The following layouts and drawing files are available:

  • Layout 1 - Test Plot Allplan Testbild / Allplan Test Layout
  • Layout 2 - Test Plot Muster & Schaffur / Patterns & Hatching
  • Layout 3 - Test Plot Allplan Testbild / Allplan Test Layout
  • Drawing file 25 - Füllflächen + Stifte / Fills + Pens
  • Drawing file 26 - Muster / Patterns (Version 2006 and later)
  • Drawing file 27 - Schraffuren / Hatching (Version 2006 and later)
  • Drawing file 100 - Allplan Test Drawing File (Version 2008 and later)


Copy these layouts and drawing files to the new project.
Select the relevant drawing files with the right mouse button and choose 'Copy to ...' on the shortcut menu.
Select the new project.

If necessary, create a layout, place the drawing files in this layout, specify an output device and and print the layout.

Note:

Make the following settings to ensure that the data is output correctly:

  • Select "white" for the background color.
  • Turn off "Color stands for pen" in "Show/Hide".
  • Turn off "Surface elements in background of each document" on the "Selection" tab of "Plot Layouts".
  • Use Windows drivers for printing.
  • For HP plotters, select the "Avoid out of memory condition" or "Output as a bitmap" option in the plotter properties.
  • For optimum color output with sRGB values, apply the settings described in the FAQ entitled Color adjustment - Windows drivers and Nemetschek vector drivers.
    https://connect.allplan.com/en/faqid/0001a106.html



Notes:

Colors in printouts can vary depending on several factors such as

  • Output device used
  • Paper used
  • Ink used
  • Driver type used (Windows or Nemetschek drivers)

In particular, colors can differ regarding

  • Color display
  • Brightness


Colors in printouts can even vary if you use the same output device but different Windows drivers.
On-screen display can be influenced by various factors such as different settings for contrast and color temperature.

As the possible settings are so widespread, you can see that it is essential to print out test data in advance.

Download PDF  FAQ_EN_Printing_test_plots.pdf
Version:  Allplan BCM 2014 / Allplan BCM 2013 / Allplan BCM 2012 / Allplan BCM 2011 / Allplan BCM 2009  | Last modified: 28.07.2015
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How can I export and import projects using Allplan Building Costs?



Note:


The following FAQ describes this topic only briefly.
For detailed information, please refer to the help by clicking Help -> Contents and Index:
Backing up data and archiving projects -> Backing up and archiving projects using archive administration -> Backing up projects


Note:

If you have received data from us or if you send data to us, please read the 'Important information' section at the end of this FAQ!

Exporting:

  • SelectProject data -->Archive...; the Archive Administration dialog box opens.
  • Click Pathand set the archive folder.
  • Please make sure that Formatis set to Archive (version 4.0 and later).You can find this setting at bottom right.
  • Select the project you want to archive in the list box on the left.
  • ClickArchive projectto start backing up the data.
  • The project appears in the list box on the right.
  • As a result, the program has created an XXX.arafile.


Importing:

  • StartAllplan Building Costs.
  • SelectProject data -->Archive...
  • Click Pathand set the archive folder.
  • The project appears in the list box on the right; select it and click Restore archive.
  • If the program asks whether you want to create a copy, you are advised to do this to protect existing data.
  • The project appears in the list box on the left; you can now edit it.




Important information:

You can use this type of archiving to back up project data. Please note that this backup does not contain the complete database!
This type of archiving is very useful if you want to transfer data to technical support.
If you send a project, please do not forget to provide us with a detailed description of the problem.
This description should include the following information:

  • Program and version
  • When does the error occur? Or what did you do when the error occurred?
  • What does the error message say? A screenshot would be very helpful.
    (Pressing the Printkey copies the current contents of the screen to the Clipboard. Using CTRL+V, you can paste this screenshot into a Word document, save this file and send it to us.)
  • Office name or customer number and telephone number so that we can contact you.

We kindly ask you not to make any changes in the project in the meantime.

A note on fixed projects:
Please do not copy any data from a corrupt project to a fixed project as this may transfer the corrupt data to your current project!

Download PDF  FAQ_EN_Exporting_importing_projects_.pdf
Version:  Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011 / Allplan 2009  | Last modified: 11.07.2016
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How can I move NemSLock License Server to a new server?



Answer:

If you want to run NemSLock 2006 Server on a different or new server, you first need to render the license ineffective. For this, you still require the old server. After this, you need to contact Nemetschek Allplan Systems GmbH in order to activate the license for the new server.

As soon as you return the license, the status of the existing license is set to trial for 48 hours; then it will expire.

Note:Transfer the license to the new server while the old server is still available.

Do the following:

  • At the new server:install NemSLock 2006 Server with the temporary license files provided with the program.
  • At the clients:Exit Allplan on all workstations.
  • At the old server:return the license(s). Open NemSLock 2006 Server Console, click "Stop server", switch to "Modules" and click "Transfer license permanently". Then select "Next" and "Create". Click the "Send" button to send the .hwchs file you just created to "register@nemetschek.de" (provided an email program is installed and configured on this server). Otherwise, click "Browse" to open the folder with the .hwchs file in Windows Explorer. Now you can use any computer to send this file to the address mentioned above.
    Finally, click "Start server". The existing licenses are valid for two more days.
  • At the clients:for the time being the clients can continue to work with the old license server.
  • At the new server:After a few minutes, our server will send you an email confirming that the licenses have been returned. Now you can generate registration requests for all licenses. Next, install the licenses.
  • At the clients:Now you can switch the clients one after the other to the new server. To do this, open the License Manager by clicking Start -> (All) Programs -> Nemetschek -> Nemetschek Softlock 2006 -> License Manager.




Tip:

To transfer the existing users to the new server, back up the Users.mcf file, which you can find in the program folder of NemSLock 2006 Server, and copy this file to the new server after the installation. Prior to copying the file, stop the "NemSLock Server 2006" Windows service, copy the file to the program folder and start this service again.

Download PDF  FAQ_EN_Moving_NemSLock_Server_to_a_new_server_(short...
Version:  Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011  | Last modified: 17.05.2017
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

I want to update the operating system of my computer. As far as I know, I have to return the license. How should I proceed?


Answer:

Use your computer to return the license before you switch to another operating system.

  • To return the license, select
    Start -> (All) Programs -> Nemetschek -> Nemetschek SoftLock 2006 -> License Manager
    (Services application -> Utilities -> License -> License Manager (NemSLock)).

    Click "Relocate licenses-> Transfer licenses permanently to a computer" -> click "Next" and then "Create". The 'Send hardware change file (*.hrdwchg)' dialog box opens. Click 'Browse'.
    The program creates and saves the COMPUTERNAME.hrdwchgfile. Then Windows Explorerstarts and the folder with the hardware change file opens. You can now use all the options provided by Windows Explorer: for example, you can attach the file to an email, copy it to a computer having Internet access and so on. Email this file to register@nemetschek.de.


Note:
After you have created this file, the Allplan license of your old computer will still be valid for two more days.
As soon as we have removed the registration, we will send you a confirmation by email.


You can now switch to the new operating system.
After having done this, you need to register the license for the new system.

  • To register the license, select
    Start -> (All) Programs -> Nemetschek -> Nemetschek SoftLock 2006 -> License Manager
    (Services application -> Utilities -> License -> License Manager (NemSLock)).
  • Select the license entry for your seat and click "Request license". Follow the instructions
    displayed on screen.
  • Create a new registration request (register.txt) and email this file to register@nemetschek.de.



You will promptly receive the final license.
Finally, install this license file to complete the switch.


Download PDF  FAQ_EN_Returning_license_because_of_new_operating_sy...
Version:  Allplan 2017  | Last modified: 08.05.2019
1 user(s) found this FAQ helpful

Question:

What license issues do I need to consider when upgrading from Allplan 2014/2015/2016 to Allplan 2017?



Answer:

Allplan 2016 introduced a new protection system. Since then licensing has been based on CodeMeter by Wibu Systems AG. Allplan 2017 uses this protection system, too.




1. Upgrading stand-alone workstations

1a. Stand-alone workstation - upgrading from Allplan 2016
The license for Allplan 2017 updates automatically. Start Setup and follow the instructions displayed. When you are prompted to select the license file, click 'Use active license'.
Follow the installation instructions.

Note: The licenses only update automatically when you upgrade. To install Allplan 2017 on a new computer, please read the following instructions: https://connect.allplan.com/en/faqid/20150618131629.html

You can find your Product Key in Allplan Connect as usual. Go to http://connect.allplan.com/license

1b. Stand-alone workstation - upgrading from Allplan 2014 or 2015
Start Setup and follow the instructions displayed. When you are prompted to select the license file, click 'License activation'. Enter your Product Key (26-digit code) and click 'Activate license'. By activating your license, you connect it with your computer. Follow the installation instructions.
You can find detailed information at
https://connect.allplan.com/en/faqid/20150618130717.html





2. Upgrading license server workstations

2a. License server workstations - upgrading from Allplan 2016
Start by updating your license(s) at the license server. After this, upgrade the clients.

Check the version of the license server. If you use the license server 2016-1-4 or later, you can find the version number (Build-ID) at bottom left in the License Settingsprogram. The version number should be at least 1.614.x.x. If you cannot see the Build-ID, you work with an older license server. In this case, update the license server first. Download the software for the license server from Allplan Connect.

You can find detailed information at
https://connect.allplan.com/en/faqid/20160527114300.html

After having updated the licenses, you can upgrade Allplan at the clients. Start Setup and follow the instructions displayed. The license server license will be detected automatically on the network. When you are prompted to select the license file, click 'Use active license'. Follow the installation instructions.

Note: You can update the licenses only at a license server you have already installed. If you want to switch to Allplan 2017 and move the license server to a new server, please read the following instructions:
https://connect.allplan.com/en/faqid/20150618134224.html
You can find your Product Key for Allplan 2016 in Allplan Connect as usual. Go to http://connect.allplan.com/license

2b. License server workstations - upgrading from Allplan 2014 or 2015

Start by installing the license server. After this, upgrade the clients.
You can find detailed information at
https://connect.allplan.com/en/faqid/20150618084450.html


Downloading licenses from Allplan Connect

You can find your license for Allplan 2014 BCM and the activation code for Allplan 2017 IBDin Allplan Connect. As an extra servicewe provide the old licenses for hardlock stand-alone workstations, the temporary licenses for NemSLock and the Product Keys for the new software protection system. Click
Profile > License administration.
Only administrators can use this function.

Download PDF  FAQ_EN_How_to_handle_licenses_when_upgrading_to_Allp...
Version:  Allplan 2018 / Allplan 2017  | Last modified: 01.11.2017
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How can I use data from the "Shell" module in Allplan 2017 and later?



Answer:


Data conversion in Allplan 2017

Allplan 2017automatically converts shell data from earlier versions the first time you open the project or *.ndw file in question.

Alllayouts you created ofgeneral arrangement drawings and reinforcement drawings stay as they are!
The 3D reinforcement modelstays as it is!
Theshell entitybecomes a 3D solid.
The views and sections(including reinforcement) become 2D elements and text.

Editing the data

As the old shell entitybecomes a 3D solid(construction lines) and the 3D reinforcement model stays as it is, you can create new associative views and sections from the model data.
Before you can do this, you need to assign "normal" format properties to the 3D solid created from the shell entity, as you cannot create associative views and sections from a solid in construction line format.

You canplace, modify and labelthe reinforcement without any restrictions. You can create schemas, legends andreportsas usual.




Download PDF  FAQ_EN_Shell_module_no_longer_available.pdf