Search Result

1 - 10 (16)
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018  | Last modified: 10.12.2020
 

Question:

  • Why can't I create elements?
  • Why can't I move a drawing?
  • Why are elements not created correctly?
  • Why does the program crash when I import a DXF file from the land registry office?
  • Why is the outline of a circumscribed area not detected correctly?
  • Why can't I calculate shadows?
  • Why are elements not displayed correctly in animation?
  • Why are parts of dimension text missing?
  • Why do the contents of the screen suddenly rotate?
  • Why can't I get a preview when I move or copy elements?
  • Why are areas not calculated correctly?




Finding the reason for these problems:

Check whether an offset is set in the project settings (File -> New Project, Open Project-> select the project and open the shortcut menu -> Properties; Allplan 2009 and earlier: Tools -> Options ->Advanced Draft -> Settings). If there are offset coordinates, clear the check box.

Select Tools -> Measure(->)Coordinates.
Click in the middle of the drawing in plan view.
If there are very large values (for example, x/y/z greater than 5000 m), you have found the reason for these problems.

The system has problems calculating and displaying data with very large coordinates. The more data you have with very large coordinates, the greater this effect.



Solution:

  • Click Tools -> Options... -> Desktop environment -> Generaland select Optimize working with large coordinates(Allplan 2009 and earlier: Tools -> Options -> Global Options -> Miscellaneous tab -> Optimize working with large coordinates). After this you must restart Allplan. Otherwise, this setting has no effect.

This is a user setting you must define separately for each user.

  • Usually, the best solution is to move the data towards the Allplan origin. Use the "Move" tool. When Allplan prompts you to specify the target point ("To point"), select Global point in the dialog line. You can find detailed information in the help for Allplan. Look for the Global pointtopic.



Note:

If the data are still not displayed correctly, do the following:
Exit Allplan -> Services application-> Service -> Hotline Tools-> cleanup -> start Allplan.

Download PDF  FAQ_EN_Large_coordinates.pdf
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 01.10.2020
 

Question:

A new computer is to replace the existing one.
How can I transfer the existing data and settings of the existing Allplan installation to the new computer?



Solution:

Please note that this solution only works with stand-alone versions.
Install the same version of Allplan on the new computer and transfer the data as follows:

1st - transferring the data:
Transfer the following folders from the old computer to the new one:
Project folder (PRJ)
Office standard folder (STD) and
User folder (USR)

You can determine the path to these folders on both the new computer and the old computer as follows:
Services application->Service->Hotline Tools->Showcfg: shows system variables ->OK
You can find the paths to the folders after PRJ, STD and USR.

2nd - transferring the toolbar configuration:
Export the configurations from the old computer by clicking View -> Toolbars -> Customize... -> Export...
You can then import the configurations to the new computer by clicking View -> Toolbars -> Customize... -> Import...

Download PDF  FAQ_EN_Installation_on_a_new_computer_with_data_tran...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011  | Last modified: 05.10.2020
 

Question:

I just installed an upgrade. How can I convert all the projects at once?



Answer:

Back up all the projects beforehand!

Do the following:

  • Exit Allplan on all workstations.
  • Only when working with Workgroup Manager:
    Log in as the Allplan administrator (sysadm).
  • Start the Services application.
  • Only when working with Workgroup Manager:
    Make sure all the computers where projects are located are up and running.
    To check this, select:
    Services application -> Workgroup Manager -> Information -> Display Project List(the second column displays the computer where the project is located).
  • Go to the computer where you want to convert the data and set the drawing file size to the maximum value:
    Services application->Service ->Hotline Tools->docsize ->512 (or 1024, if available) ->OK
    Note:
    After data conversion, you can set the drawing file size back to the initial value.
  • Start converting the data (use the computer where you have changed the drawing file size):
    Services application ->Service ->Hotline Tools -> datwaprjs: convert data of all projects
    If you reply "Yes" at the following two prompts, the program will convert the data of all projects.



Notes:

The time it takes to convert the data depends on various factors:

  • Number of projects
  • Size of each project
  • Performance of the computer converting the data
  • Network performance


It is possible to start data conversion from several workstations at the same time.

Download PDF  FAQ_EN_Converting_all_Allplan_projects_in_a_single_o...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 01.10.2020
 

Question:

What are the differences between a major release, a service release and a hotfix?



Answer:

Major release

The major release is the first release of a new version.
You can download it from the homepage.

Download:
www.connect.allplan.com -> Download -> Software packages
(requires login details for Allplan Connect)

Name (example):
Allplan 2015


Service release

A service release is a collection of improvements to the program, including all the service releases and hotfixes that have been released until now. In addition to improvements, it may also include new features.
You can also use a service release for a new installation or an upgrade (from a previous version).
You can download it from the homepage.
New customers get it as a DVD. Serviceplus customers get it on request.
In addition, they automatically get information about service releases.

Download:
www.connect.allplan.com -> Download -> Software packages
(requires login details for Allplan Connect)

Name (example):
Allplan 2015-1


Hotfix

A hotfix is an improvement to the program that will automatically be installed by Allplan Update.
The basis for the installation is a specific major release or service release.
Hotfixes are installed one after the other in the correct order, that is to say, first Hotfix 2015-1-1 and then Hotfix 2015-1-2.

Allplan automatically installs available hotfixes when it starts.

You can find more information on hotfixes in the following FAQ:
https://connect.allplan.com/en/faqid/20101203111503.html




Tip:

Install program updates as soon as they are available.

Download PDF  FAQ_EN_Program_updates.pdf
Version:  Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011  | Last modified: 15.11.2017
 

Question:

How can I update cross-section catalogs or install country-specific cross-section catalogs in Allplan 2011 and later?



Answer:

To install and save cross-section catalogs in Allplan 2011 and later, select Tools -> Defaults -> Cross-Section Catalogs. A dialog box opens. You can find a folder symbol and a disk symbol at bottom left.

To install cross-section catalogs, use the folder symbol. Another dialog opens, where you can select the cross-section catalog file you want to install. Select the file to be installed and click "Open" to confirm. This installs the corresponding cross-section catalog, which you can now use in Allplan.
To install country-specific cross-section catalogs, select the "Ing" folder, which was created when you installed Allplan. You can find it in the Allplan installation path (e.g., c:\Nemetschek\Allplan 201x\New\Ing - more information on the Allplan installation path is provided below in the "Notes" section).
This folder includes the country-specify cross-section catalog files.

To save a custom cross-section catalog, use the disk symbol. Another dialog opens, where you can select any folder to save the cross-section catalogs currently used in Allplan.



Note:

To update cross-section catalogs, you may need administrator privileges. If necessary, log on as an administrator before you start the update.

To use the cross-section catalogs for a specific project only, set the path settings for the cross-section catalogs of this project to project before you install the cross-section catalogs. In Allplan, open the "File" menu and select "Open Project..." Click the corresponding project with the right mouse button. Select "Properties". A dialog box opens. In the "Path settings" area, set the "Bar and mesh cross-section catalogs" to "Project".

To determine the path where Allplan is installed, use the Services application and select Service -> Hotline Tools-> showcfg. The Services application window shows the path of the Allplan installation folder.

The following abbreviations are used for the country-specific cross-section catalogs in the file names (axyzqusr.txt):
aut Austria
bel Belgium
bra Brazil
bul Bulgaria
deu Germany
eng England
fra France
hol Holland
hrv Croatia
ita Italy
kor Korea
pol Poland
rum Romania
rus Russia
slk Slovakia
svn Slovenia
swi Switzerland
tch Czech Republic
ung Hungary
usa USA

Download PDF  FAQ_EN_Updating_cross-section_catalogs_(Allplan_2011...
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014  | Last modified: 25.11.2019
 

Question:

How can I permanently change the path settings presented for selection in specific tools (save, import)?



Answer:

When you save, import and export elements or files, Allplan automatically proposes a specific folder where the data is saved or taken from.
You can specify which Allplan file type is saved in which folder. These folders are automatically presented in the "Save" dialog box of the relevant file type. However, you can change them at any time.

To set this proposed folder on an individual basis, do the following:
Select the Tools menu ->Options... -> Desktop environment(Allplan 2009 and earlier: Tools -> Options... -> Global Options-> "Settings"tab).

You can click thePAah setting sbutton to the right of Folders for savingto define defaults. You can choose Project, Private, Custom or Last for the path setting:

  • Project: the file type is saved in the current project (not available for NDW and NPL files).
  • Private: the file type is saved in the user's private project.
  • Custom: you can specify any folder for the file type. To select the folder, click the path displayed in the Folder column and enter a new path or click ... in the Browse column and select the path in a dialog box.
  • Last: the file type is saved in the path you selected last.
Download PDF  FAQ_EN_Default_path_settings.pdf
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 23.10.2020
 

Problem:

Printing with Windows printer drivers is only possible in a restricted way or not possible at all.



Solution:

Resetting all the files with the default values in question involves several steps.
Work through these steps one after the other and check whether the problem is solved after each step.

Step 1

Check whether you can print a test page.
Start -> Control Panel -> Devices and Printers -> select the printer -> Printer properties -> General tab -> Print Test Page.

If you can print the test page but you still cannot print from Allplan -> step 2.

Step 2

Carry out the cleanprint hotline tool.
Exit Allplan, start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanprint -> OK

If the problem still occurs -> step 3

Step 3

Reset the plastw.dat file.
Exit Allplan, start the Services application and do the following:
Service -> Hotline Tools -> cleanstd: resets CAD defaults -> OK
Information is displayed. Confirm it by clickingOK.
question: would you like to reset all CAD settings? It is essentialthat you clickNo.
A dialog box with a list is displayed. Select the plastw.dat file and confirm by clicking OK.

Now it should be possible to print without any problem.



Note:

You can find up-to-date printer drivers provided by the printers' manufacturers on the Internet.
If you have problems with the printer, please download the current driver and install it.

Hewlett Packard: http://www.hp.com
Epson: http://www.epson.de
Océ: http://www.oce.de
Canon: http://www.canon.de
Brother: http://www.brother.de
Lexmark: http://www.lexmark.de

Download PDF  FAQ_EN_Resetting_Windows_printer_drivers_in_Allplan....
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 30.09.2020
 

Question:

I have used the "Check out" tool to check out the computer from the network and remove the network connection.
Why is Workgroup Manager no longer working?



Answer:

Windows disables network functionality as soon as you remove the network connection (unplug the network cable).
Running Allplan, however, requires specific network protocols (even if the computer is checked out).



Solution:

To make sure that the operating system's network functionality is not interrupted, you can install a virtual network interface card.
Microsoft provides a driver for this (loopback adapter).

How to install:

Windows 8/10:
Right-click the Windows Start button -> select "Run".
Type in "hdwwiz" in the search field. Right-click the program found -> select "Run as admin".
Click Next -> select the required hardware manually in a list and install it -> click "Next".
Select "Network adapter" in the list -> click "Next".
Select "Microsoft" in the list on the left -> "Microsoft loopback adapter for KM TEST" is presented for selection on the right -> click "Next" -> click "Next".

Windows 7:
Click the Windows Start button -> type in "hdwwiz" in the search field. Right-click the program found -> select "Run as administrator".
Click Next -> select the required hardware manually in a list and install it -> click "Next".
Select "Network adapter" in the list -> click "Next".
Select "Microsoft" in the list on the left -> "Microsoft loopback adapter" is presented for selection on the right -> click "Next" -> click "Next".

Windows Vista:
Start the "Hardware Wizard" by selecting
Start -> Control Panel -> Hardware and clicking Continue -> Next.
Select "Install the hardware that I manually select from a list (advanced)" in the box and choose "Network adapter" in the list that follows.
This selects and installs the "Microsoft loopback adapter".

Download PDF  FAQ_EN_Installing_loopback_adapter_for_a_stand-alone...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 16.12.2020
 

Question:

What can I do if Allplan does not start?


Answer:


Work through the following steps:

Step 1 - run as administrator
Start Allplan with the ‘Run as administrator’ option.
To do this, right-click the Allplan icon and click ‘Run as administrator’.
If Allplan does not start, go to step 2.

Step 2 - cleanup
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanup -> OK
If Allplan does not start, go to step 3.

Step 3 - cleanstd
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanstd: reset CAD defaults -> OK -> OK -> Yes -> OK
If Allplan does not start, restore the settings:
Services application -> Service -> Hotline Tools -> laststd: restore the last settings -> OK -> OK -> Yes -> OK
Go to step 4.

Step 4 - cleanreg
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanreg: reset CAD registry settings -> OK -> OK -> Yes -> OK
If Allplan does not start, restore the registry settings:
Services application -> Service -> Hotline Tools -> lastreg:restore most recent CAD registry settings -> OK -> OK -> Yes -> OK
Go to step 5.

Step 5 (Allplan 2016 and later)
Restart the Wibu service:
Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.

CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.

If Allplan does not start, go to step 6.

Step 6 (Allplan 2016 and later)
Go to the Wibu website and install CodeMeter User Runtime Version for Windows (64-bit version).
You can find the installation program at https://www.wibu.com/de/anwendersoftware.htmlor on the Nemetschek FTP server ftp://nemhotline:ha37jvg8f@ftp.nemetschek.deat download/General/Wibu/CodemeterRuntime.exe

Start the ‘CodeMeterRuntime.exe’ file.
To do this, right-click this file and select
‘Run as administrator’.
Confirm all messages displayed and the defaults by clicking ‘Next’.
CodeMeter Control Center will be installed afterwards.
If Allplan does not start, go to step 7.

Step 7 - contact Technical Support
Send the following information by email to support.de@allplan.com:

  1. An exact description of the last step before the error or crash occurred.
  2. The error message itself (as a screenshot). To find out how to take a screenshot, look at
    https://connect.allplan.com/en/faqid/0001cb36.html
  3. A support request (Hotinfo) with question 01. To find out how to create a support request, look at
    https://connect.allplan.com/en/faqid/20140528094911.html
  4. The 'Allplan.out' log file. To find out how to create a support request, look at
    https://connect.allplan.com/en/faqid/0001a27a.html
  5. Allplan 2016 and later -> a screenshot of the Wibu Control Center. To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.


We will contact you.

Download PDF  FAQ_EN_Allplan_does_not_start.pdf
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015  | Last modified: 30.12.2020
 

Question:

What can I do if Allplan no longer starts after I have upgraded and the following messages appear?
Allplan
Stop

...

After this, Quality Reporter displays an error report.



Answer:

Exit Allplan on all workstations and do the following:
Open the Services application and make a note of the path to the 'central file storage folder', which is displayed in the Services application window.
In addition, check whether the workgroup manager line is followed by 'Yes' or 'No'.

Open the central file storage folder in Windows Explorer.

If the workgroup manager line is followed by
'Yes', open the NET subfolder.
'No', open the PRJ subfolder.

Find the 'project.dat' or 'project.Dat.xm' file in the NET or PRJ folder and rename it 'project-old.dat'.

After this, do the following:
Services application -> Service -> Hotline Tools -> reorg -> OK -> Restore project management file -> OK
The program creates a new, correct project management file and you can start Allplan again.



Note:

If you come across error messages while doing this, please email the following information to support@allplan.com:

  1. Describe exactly what you did before the error or crash occurred.
  2. The error message itself (as a screenshot).
  3. The log file (trace).
    https://connect.allplan.com/en/faqid/0001a27a.html
  4. A Hotinfo support request with question 01.
    https://connect.allplan.com/en/faqid/20130823123806.html
Download PDF  FAQ_EN_Allplan_does_not_start_after_upgrade_Stop_mes...
1 - 10 (16)
https://campus.allplan.com/ uses cookies  -  More information

Accept