Version:  Allplan 2020 / Allplan 2019 / Allplan 2018  | Last modified: 03.11.2020
4 user(s) found this FAQ helpful

Question:

  • Why can't I create elements?
  • Why can't I move a drawing?
  • Why are elements not created correctly?
  • Why does the program crash when I import a DXF file from the land registry office?
  • Why is the outline of a circumscribed area not detected correctly?
  • Why can't I calculate shadows?
  • Why are elements not displayed correctly in animation?
  • Why are parts of dimension text missing?
  • Why do the contents of the screen suddenly rotate?
  • Why can't I get a preview when I move or copy elements?
  • Why are areas not calculated correctly?




Finding the reason for these problems:

Check whether an offset is set in the project settings (File -> New Project, Open Project-> select the project and open the shortcut menu -> Properties; Allplan 2009 and earlier: Tools -> Options ->Advanced Draft -> Settings). If there are offset coordinates, clear the check box.

Select Tools -> Measure(->)Coordinates.
Click in the middle of the drawing in plan view.
If there are very large values (for example, x/y/z greater than 5000 m), you have found the reason for these problems.

The system has problems calculating and displaying data with very large coordinates. The more data you have with very large coordinates, the greater this effect.



Solution:

  • Click Tools -> Options... -> Desktop environment -> Generaland select Optimize working with large coordinates(Allplan 2009 and earlier: Tools -> Options -> Global Options -> Miscellaneous tab -> Optimize working with large coordinates). After this you must restart Allplan. Otherwise, this setting has no effect.

This is a user setting you must define separately for each user.

  • Usually, the best solution is to move the data towards the Allplan origin. Use the "Move" tool. When Allplan prompts you to specify the target point ("To point"), select Global point in the dialog line. You can find detailed information in the help for Allplan. Look for the Global pointtopic.



Note:

If the data are still not displayed correctly, do the following:
Exit Allplan -> Services application-> Service -> Hotline Tools-> cleanup -> start Allplan.

Download PDF  FAQ_EN_Large_coordinates.pdf
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011  | Last modified: 05.10.2020
19 user(s) found this FAQ helpful

Question:

I just installed an upgrade. How can I convert all the projects at once?



Answer:

Back up all the projects beforehand!

Do the following:

  • Exit Allplan on all workstations.
  • Only when working with Workgroup Manager:
    Log in as the Allplan administrator (sysadm).
  • Start the Services application.
  • Only when working with Workgroup Manager:
    Make sure all the computers where projects are located are up and running.
    To check this, select:
    Services application -> Workgroup Manager -> Information -> Display Project List(the second column displays the computer where the project is located).
  • Go to the computer where you want to convert the data and set the drawing file size to the maximum value:
    Services application->Service ->Hotline Tools->docsize ->512 (or 1024, if available) ->OK
    Note:
    After data conversion, you can set the drawing file size back to the initial value.
  • Start converting the data (use the computer where you have changed the drawing file size):
    Services application ->Service ->Hotline Tools -> datwaprjs: convert data of all projects
    If you reply "Yes" at the following two prompts, the program will convert the data of all projects.



Notes:

The time it takes to convert the data depends on various factors:

  • Number of projects
  • Size of each project
  • Performance of the computer converting the data
  • Network performance


It is possible to start data conversion from several workstations at the same time.

Download PDF  FAQ_EN_Converting_all_Allplan_projects_in_a_single_o...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 01.10.2020
12 user(s) found this FAQ helpful

Question:

A new computer is to replace the existing one.
How can I transfer the existing data and settings of the existing Allplan installation to the new computer?



Solution:

Please note that this solution only works with stand-alone versions.
Install the same version of Allplan on the new computer and transfer the data as follows:

1st - transferring the data:
Transfer the following folders from the old computer to the new one:
Project folder (PRJ)
Office standard folder (STD) and
User folder (USR)

You can determine the path to these folders on both the new computer and the old computer as follows:
Services application->Service->Hotline Tools->Showcfg: shows system variables ->OK
You can find the paths to the folders after PRJ, STD and USR.

2nd - transferring the toolbar configuration:
Export the configurations from the old computer by clicking View -> Toolbars -> Customize... -> Export...
You can then import the configurations to the new computer by clicking View -> Toolbars -> Customize... -> Import...

Download PDF  FAQ_EN_Installation_on_a_new_computer_with_data_tran...
Version:  Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011  | Last modified: 15.11.2017
1 user(s) found this FAQ helpful

Question:

How can I update cross-section catalogs or install country-specific cross-section catalogs in Allplan 2011 and later?



Answer:

To install and save cross-section catalogs in Allplan 2011 and later, select Tools -> Defaults -> Cross-Section Catalogs. A dialog box opens. You can find a folder symbol and a disk symbol at bottom left.

To install cross-section catalogs, use the folder symbol. Another dialog opens, where you can select the cross-section catalog file you want to install. Select the file to be installed and click "Open" to confirm. This installs the corresponding cross-section catalog, which you can now use in Allplan.
To install country-specific cross-section catalogs, select the "Ing" folder, which was created when you installed Allplan. You can find it in the Allplan installation path (e.g., c:\Nemetschek\Allplan 201x\New\Ing - more information on the Allplan installation path is provided below in the "Notes" section).
This folder includes the country-specify cross-section catalog files.

To save a custom cross-section catalog, use the disk symbol. Another dialog opens, where you can select any folder to save the cross-section catalogs currently used in Allplan.



Note:

To update cross-section catalogs, you may need administrator privileges. If necessary, log on as an administrator before you start the update.

To use the cross-section catalogs for a specific project only, set the path settings for the cross-section catalogs of this project to project before you install the cross-section catalogs. In Allplan, open the "File" menu and select "Open Project..." Click the corresponding project with the right mouse button. Select "Properties". A dialog box opens. In the "Path settings" area, set the "Bar and mesh cross-section catalogs" to "Project".

To determine the path where Allplan is installed, use the Services application and select Service -> Hotline Tools-> showcfg. The Services application window shows the path of the Allplan installation folder.

The following abbreviations are used for the country-specific cross-section catalogs in the file names (axyzqusr.txt):
aut Austria
bel Belgium
bra Brazil
bul Bulgaria
deu Germany
eng England
fra France
hol Holland
hrv Croatia
ita Italy
kor Korea
pol Poland
rum Romania
rus Russia
slk Slovakia
svn Slovenia
swi Switzerland
tch Czech Republic
ung Hungary
usa USA

Download PDF  FAQ_EN_Updating_cross-section_catalogs_(Allplan_2011...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 23.10.2020
2 user(s) found this FAQ helpful

Problem:

Printing with Windows printer drivers is only possible in a restricted way or not possible at all.



Solution:

Resetting all the files with the default values in question involves several steps.
Work through these steps one after the other and check whether the problem is solved after each step.

Step 1

Check whether you can print a test page.
Start -> Control Panel -> Devices and Printers -> select the printer -> Printer properties -> General tab -> Print Test Page.

If you can print the test page but you still cannot print from Allplan -> step 2.

Step 2

Carry out the cleanprint hotline tool.
Exit Allplan, start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanprint -> OK

If the problem still occurs -> step 3

Step 3

Reset the plastw.dat file.
Exit Allplan, start the Services application and do the following:
Service -> Hotline Tools -> cleanstd: resets CAD defaults -> OK
Information is displayed. Confirm it by clickingOK.
question: would you like to reset all CAD settings? It is essentialthat you clickNo.
A dialog box with a list is displayed. Select the plastw.dat file and confirm by clicking OK.

Now it should be possible to print without any problem.



Note:

You can find up-to-date printer drivers provided by the printers' manufacturers on the Internet.
If you have problems with the printer, please download the current driver and install it.

Hewlett Packard: http://www.hp.com
Epson: http://www.epson.de
Océ: http://www.oce.de
Canon: http://www.canon.de
Brother: http://www.brother.de
Lexmark: http://www.lexmark.de

Download PDF  FAQ_EN_Resetting_Windows_printer_drivers_in_Allplan....
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018  | Last modified: 12.11.2020
1 user(s) found this FAQ helpful

Question:

Why is Allplan running so slow?


Answer:

Check the following points:

1. Current version
Make sure you work with the current Allplan version.

  • Do the following or ask your system administrator to do this:
    Open Allplan and click the ‘?’ icon in the upper right-hand corner. Click ‘Update Allplan’.
    Select 'Find now'. If Allplan finds updates or hotfixes, download the installation packages.
  • Deactivate the virus scanner while your are installing updates or hotfixes. This might require administrator privileges. Contact your system administrator if you have problems.
  • Right-click the Allplan icon on the desktop. A shortcut menu opens.
    Select ‘Run as administrator’ and click ‘Yes’ to confirm the following message.
    As a result, Windows security settings do not block the installation.



2. System requirements:
Check the hardware and software required for your Allplan computer.

2.a)Download and run the system test.
Check the notes.
https://www.allplan.com/de/system/systemvoraussetzungen/

2.b)Check the Allplan system requirements:
https://www.allplan.com/de/system/systemvoraussetzungen/

2.c)You can find information about graphics cards at
https://connect.allplan.com/de/support/grafikkarten.html

2.d)You can find server operating systems you can use for the central file storage of Allplan at
https://connect.allplan.com/en/faqid/20140924094923.html


3. Hotline tools:
Start the Services application, open the ‘Service’ menu and select ‘Hotline Tools’. To save your settings, select the following tools.

- savestd: Saves user defaults.
- savereg: Saves CAD registry settings.

Start the Services application, open the ‘Service’ menu and select the following ‘Hotline Tools’:

- cleanup: Initializes the display.
- cleanstd: Resets CAD defaults.
- cleanreg: Resets CAD registry settings.

Check whether this has solved the problems.
If this is not so, restore the settings you just saved. To do this, start the Services application, open the ‘Service’ menu and select the following ‘Hotline Tools’:
- reststd: Restores saved user defaults.
- restreg: Restores CAD registry settings.


4. Color scheme selected in Allplan:
Start Allplan, open the ‘View’ menu, point to ‘Toolbars’ and select ‘Customize User Interface’. Open the ‘Customize’ tab and set ‘Color scheme and icon design’ to ‘Windows’.


5. Check the availability of all projects that are not online (if you use Workgroup Manager):
Start Allplan, open the ‘File’ menu and select ‘New Project, Open Project’. Deactivate ‘Check availability of all offline projects’.


6. Virus scanner
Check whether an anti-virus program is running in the background of the computer or server.
If so, reduce protection to "programs only".

Scanning "all files" can take a long time, considerably slowing down your computer when you switch between projects or exit the program.
You can exclude the Allplan installation folders from real-time scanning.When you start the Services application, you can see a list of the folders to be excluded.
You can find more information at
https://connect.allplan.com/en/faqid/20091126145752.html
Changes in the settings of the virus scanner only come into effect when you re-start the computer.


7. Aero desktop effects
Deactivate the Aero desktop effects of Windows.
To do this, open the Control Panel, select ‘Ease of Access’ and go to the ‘Make things on the screen easier to see’ area.
Select the ‘Turn off all unnecessary animations (when possible)’ option.


8. Name resolution on the network
If Allplan takes several minutes to start, name resolution on the network may not work.
To check this, do the following:
Right-click the Windows Start Button, select ‘Run’, type in ‘cmd’, click OK, type in ‘Nslookup’ and press ENTER.
Go to the line following the > character, type in the name of the Allplan data server and press ENTER.
The reply starts with the name and address of the server providing name resolution.
You can find the name and address of the Allplan data server in the second group.
If problems occur, contact your network administrator and ask him or her to configure name resolution correctly.


9. Speed of Allplan projects
Check whether some Allplan projects are slower than other Allplan projects.
Start with the empty project and check whether it is slow too.
After this, select any other Allplan project.

If it is only the current project that is slow, the problem may be caused by the data of the current project.
In this case, the data of this project must be analyzed in detail.
Contact technical support.


10. Network: checking out Allplan using Workgroup Manager
If you use Allplan with Workgroup Manager, you can check whether the problems are caused by the network. To do this, check out the workstation with the project in question and use the project on the local Allplan workstation.
You can find detailed information on checking out an Allplan workstation using Workgroup Manager in the
Services application. Open the ‘Help’ and select ‘Workgroup Manager’.

After you have checked out the workstation, Allplan no longer accesses the central file storage of the server.
If this has solved the problems, they are caused by the network. In this case, the network must be checked in detail.
Contact your network administrator and ask him or her to do this.

If the project is still slow, the problem may be caused by the data of the current project.
In this case, the data of this project must be analyzed in detail.
Contact technical support.


11. Log files and system information files
If all the points above do not solve the problems, technical support requires more system information about the computer running Allplan.

  • So, we would be grateful if you could send us a support request (Allplan Hotinfo with Allplan logging).
    To create a support request, start the Services application, open the ‘Service’ menu and select ‘Create support request (Hotinfo)’.
    Several dialog boxes open. Select ‘Technical Support Allplan’ and ‘Enquiry with Allplan logging’. Enter all the data required. Finally, click ‘Finish’.
    Another dialog box opens, prompting you to start Allplan. Click the ‘Start Allplan’ button.
    Allplan starts, logging all processes.
    Try to reproduce the problem as exactly as possible.
    Exit Allplan as soon as possible, reducing the data in the log file to a minimum.
    Then click ‘Next’ to generate the support request with the log file.
    You can find more information about Hotinfo at
    https://connect.allplan.com/en/faqid/20140528094911.html
  • To analyze the Windows system environment, we would ask you to send us the logs created by Windows Event Viewer of your computer.
    To start Windows Event Viewer, right-click the Windows Start Button, select ‘Run’ and type in ‘eventvwr.msc’.
    You can also type in ‘Event Viewer’ in the search box of Windows. This displays the link file to the Windows event logs.
    Using Event Viewer, create *.evtx files for the application log and the system log in the ‘Windows Logs’ area and for the ‘Administrative Events’ log in the ‘Custom Views’ area.


Please send us the files.

Download PDF  FAQ_EN_Allplan_is_running_slow.pdf
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 25.11.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

What can I do if Allplan does not start?


Answer:


Work through the following steps:

Step 1 - run as administrator
Start Allplan with the ‘Run as administrator’ option.
To do this, right-click the Allplan icon and click ‘Run as administrator’.
If Allplan does not start, go to step 2.

Step 2 - cleanup
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanup -> OK
If Allplan does not start, go to step 3.

Step 3 - cleanstd
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanstd: reset CAD defaults -> OK -> OK -> Yes -> OK
If Allplan does not start, restore the settings:
Services application -> Service -> Hotline Tools -> laststd: restore the last settings -> OK -> OK -> Yes -> OK
Go to step 4.

Step 4 - cleanreg
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanreg: reset CAD registry settings -> OK -> OK -> Yes -> OK
If Allplan does not start, restore the registry settings:
Services application -> Service -> Hotline Tools -> lastreg:restore most recent CAD registry settings -> OK -> OK -> Yes -> OK
Go to step 5.

Step 5 (Allplan 2016 and later)
Restart the Wibu service:
Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.

CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.

If Allplan does not start, go to step 6.

Step 6 (Allplan 2016 and later)
Go to the Wibu website and install CodeMeter User Runtime Version for Windows (64-bit version).
You can find the installation program at https://www.wibu.com/de/anwendersoftware.htmlor on the Nemetschek FTP server ftp://nemhotline:ha37jvg8f@ftp.nemetschek.deat download/General/Wibu/CodemeterRuntime.exe

Start the ‘CodeMeterRuntime.exe’ file.
To do this, right-click this file and select
‘Run as administrator’.
Confirm all messages displayed and the defaults by clicking ‘Next’.
CodeMeter Control Center will be installed afterwards.
If Allplan does not start, go to step 7.

Step 7 - contact Technical Support
Send the following information by email to support.de@allplan.com:

  1. An exact description of the last step before the error or crash occurred.
  2. The error message itself (as a screenshot). To find out how to take a screenshot, look at
    https://connect.allplan.com/en/faqid/0001cb36.html
  3. A support request (Hotinfo) with question 01. To find out how to create a support request, look at
    https://connect.allplan.com/en/faqid/20140528094911.html
  4. The 'Allplan.out' log file. To find out how to create a support request, look at
    https://connect.allplan.com/en/faqid/0001a27a.html
  5. Allplan 2016 and later -> a screenshot of the Wibu Control Center. To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.


We will contact you.

Download PDF  FAQ_EN_Allplan_does_not_start.pdf
Version:  Allplan 2020 / Allplan 2019 / Allplan 2017 / Allplan 2016 / Allplan 2015  | Last modified: 12.06.2020
1 user(s) found this FAQ helpful

Question:

What can I do if Allplan no longer starts after I have upgraded and the following messages appear?
Allplan
Stop

...

After this, Quality Reporter displays an error report.



Answer:

Exit Allplan on all workstations and do the following:
Open the Services application and make a note of the path to the 'central file storage folder', which is displayed in the Services application window.
In addition, check whether the workgroup manager line is followed by 'Yes' or 'No'.

Open the central file storage folder in Windows Explorer.

If the workgroup manager line is followed by
'Yes', open the NET subfolder.
'No', open the PRJ subfolder.

Find the 'project.dat' or 'project.Dat.xm' file in the NET or PRJ folder and rename it 'project-old.dat'.

After this, do the following:
Services application -> Service -> Hotline Tools -> reorg -> OK -> Restore project management file -> OK
The program creates a new, correct project management file and you can start Allplan again.



Note:

If you come across error messages while doing this, please email the following information to support@allplan.com:

  1. Describe exactly what you did before the error or crash occurred.
  2. The error message itself (as a screenshot).
  3. The log file (trace).
    https://connect.allplan.com/en/faqid/0001a27a.html
  4. A Hotinfo support request with question 01.
    https://connect.allplan.com/en/faqid/20130823123806.html
Download PDF  FAQ_EN_Allplan_does_not_start_after_upgrade_Stop_mes...
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 25.11.2019
3 user(s) found this FAQ helpful

Question:

How can I restore a lost building structure or layout structure?



Answer:

To restore a lost or corrupt building structure or layout structure, you can do the following:

  • Close Allplan.
  • Open Windows Explorer, go to the central file storage folder of Allplan and open the "Prj"folder. Open the corresponding project folder and the "BIM" subfolder.

    Note:
    If the "Same folder name as project name" option is not selected for the project, a number is used for the folder name in the "Prj"folder. In this case, open the Services applicationand select the woprohotline tool (Services application -> Service -> Hotline Tools -> wopro). Select the corresponding project by double-clicking its name. An information dialog box shows the folder and file name of the project.
  • You can find an XML file for each structure in the BIM subfolder.


Building structure:
Allplan_BIM_BuildingStructure.xml

Objects derived from building structure:
Allplan_BIM_Views.xml

Plane model:
Allplan_BIM_LevMo_"name of model".xml

Layout structure:
Allplan_BIM_LayoutStructure.xml

  • To restore the building structure from a backup, rename the existing file "Allplan_BIM_BuildingStructure.xml" "Allplan_BIM_BuildingStructure.xml.old", for example.
  • Switch to the "Backup"folder, which you can also find in the"BIM"folder.
  • Select the most recent file that had been created beforethe building structure was deleted, for example, "Allplan_BIM_BuildingStructure.xml.27.5.2008--10-32-21.bak". The characters in bold indicate the date and time of the backup. Copy this file to the "BIM"folder.
  • Rename this file by deleting the characters after ".xml". Now the file name is "Allplan_BIM_BuildingStructure.xml".
  • Restart Allplan. The last version of the building structure is displayed in the "Open on a project-specific basis"dialog box again.




Note:

Using Allplan 2009-2 and later, you can restore the layout structure from a *.bak file straight from the "Open on a project-specific basis: layouts"dialog box.

  • Right-click the topmost structural level in the layout structure (project name) and select Load layout structure favoriteon the shortcut menu.
  • Open the last version of the Allplan_BIM_LayoutStructure.xml file in the backup folder mentioned above.


If the *.bak files are not displayed, please follow the steps described above.

Download PDF  FAQ_EN_Restoring_building_structure_layout_structure...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 01.10.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

Does Allplan create backup files (*.bak)?
How can I use these files?



Answer:

Allplan creates backup files when you do the following:

  1. Copy, Move Elements between Documents …
    Allplan creates a backup file of the destination drawing file or layout.
  2. Deleting drawing files and layoutsin the "Open on a project-specific basis" dialog box
    If you have selected "Create backup copies of drawing files", Allplan creates a backup file of the drawing file or layout.
  3. Importing data to drawing files
    If you have selected "Create backup copies of drawing files", Allplan creates a backup file of the drawing file.


Note on points 2 and 3:

To select the "Create backup copies of drawing files" option, click
Tools -> Options -> Desktop environment -> Save/load area (until V2009 Global Options -> Miscellaneous -> Autosave, Backup)->Create backup copies of drawing files.


Restoring:

If need be, you can restore the original drawing file or layout.
Make a note of the drawing file number or layout number and determine the corresponding project folder as follows:
Services application -> Service -> Hotline Tools -> wopro

Open this folder in Windows Explorer.

Rename the corresponding drawing file "tb000001.ndw" "tb000001.ndw.old" or the corresponding layout "pb000001.000" "pb000001.000.old.", for example.
Delete the bak extension from the corresponding bak file.

Example 1:

You have inadvertently copied the wrong elements to drawing file 4711.
1st step: exit the project in Allplan.
2nd step: delete file tb004711.ndw or rename it tb004711.ndw.old.
3rd step: find file tb004711.ndw.bak and rename it tb004711.ndw.

Example 2:

You have inadvertently copied the wrong elements to layout 815.
1st step: exit the project in Allplan.
2nd step: delete file pb000815.000 or rename it pb000815.000.old.
3rd step: find file pb000815.000.bak and rename it pb000815.000.



Note:

These backup files can considerably increase the volume of data to be backed up. So it is a good idea to delete the .bak files you no longer require before you start backing up data. To delete the .bak files, you can select the Services application and click Utilities -> Delete temporary files.

You can also find this information in the help for Allplan. Please refer to the topic "Using bak files".

Download PDF  FAQ_EN_Using_bak_files.pdf