Search Result

1 - 10 (25)
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018  | Last modified: 14.12.2020
 

Question:

How can I work from home with Allplan without a direct LAN connection to a common file storage folder?



Answer:

1. Working from home with direct access to the central data


If you want to work together on projects, you can use Allplan Share, Allplan’s cloud solution, to work with Allplan without a LAN connection to the central file storage folder. This is only possible if Allplan is installed as a standalone version on a computer without access to a central file storage folder; otherwise, Allplan does not start. If the computer is part of a workgroup installation, the computer must be checked out and used outside the LAN (like a standalone workstation). Data access is via cloud services.
This is only possible if you use Allplan Share for cloud storage.

Working with Allplan Share is just as simple as working at a standalone workstation. You and several other users can access and edit a project at the same time.

To get more information on Allplan Share, use the following link or contact your sales partner:

https://www.allplan.com/de/add-ons/allplan-share/


You can also find further information on Allplan Connect; use the following link:


https://connect.allplan.com/de/forum/themen/topic/topics/cad-allgemein-1/moderierter-sammelbeitrag-zugriff-auf-allplan-projekte-aus-dem-homeoffice-via-allplan-share.html


Note:

VPN is not useful for common project storage.
Allplan exchanges many files with the data server. VPN uses advanced encryption, which considerably slows down data transfer.
A connection via VPN is not approved for Allplan because data might get damaged even if the connection is interrupted only briefly. In addition, working over the internet is extremely slow if the internet connection is not fast enough (at least 100 Mbit).
Allplan does not support a VPN connection with IPv6; Allplan detects only IPv4.
Make sure that the VPN connection does not switch to sleep mode.

Please note that we cannot provide support for this constellation.



2. Working from home without access to the central file storage (working locally):



2.1 Allplan with workgroup manager:

If workgroup manager is included in your license, you can check out a computer or laptop with projects from the workgroup environment. You can then work from home without access to the server. The projects on the computer or laptop that is checked out are locked for the CAD users on the network. These users see the comment you entered when you checked out the computer.

You can find instructions at

https://connect.allplan.com/en/faqid/20160923105251.html

When you use a license server, you can get the license via a VPN connection or borrow the license beforehand:

https://connect.allplan.com/en/faqid/20180109095437.html
https://connect.allplan.com/en/faqid/20160523165423.html




2.2 Allplan without workgroup manager:

Using the office computer
If you have neither workgroup manager nor network access, you must uninstall Allplan and install it again by specifying the local paths. To work with a project, you must back it up and then import it to the local installation.

Using a new (private) computer
If you want to use a new computer to work from home, you must return the license at the office computer and then use this license to install Allplan on the new computer.


We recommend that you do not mix data from the office computer and the private computer. Merging data later involves considerable time and effort.

Use the following link to find out how to transfer projects:

https://connect.allplan.com/en/faqid/20180507154505.html

Download PDF  FAQ_EN_Working_with_Allplan_from_home.pdf
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018  | Last modified: 10.12.2020
 

Question:

  • Why can't I create elements?
  • Why can't I move a drawing?
  • Why are elements not created correctly?
  • Why does the program crash when I import a DXF file from the land registry office?
  • Why is the outline of a circumscribed area not detected correctly?
  • Why can't I calculate shadows?
  • Why are elements not displayed correctly in animation?
  • Why are parts of dimension text missing?
  • Why do the contents of the screen suddenly rotate?
  • Why can't I get a preview when I move or copy elements?
  • Why are areas not calculated correctly?




Finding the reason for these problems:

Check whether an offset is set in the project settings (File -> New Project, Open Project-> select the project and open the shortcut menu -> Properties; Allplan 2009 and earlier: Tools -> Options ->Advanced Draft -> Settings). If there are offset coordinates, clear the check box.

Select Tools -> Measure(->)Coordinates.
Click in the middle of the drawing in plan view.
If there are very large values (for example, x/y/z greater than 5000 m), you have found the reason for these problems.

The system has problems calculating and displaying data with very large coordinates. The more data you have with very large coordinates, the greater this effect.



Solution:

  • Click Tools -> Options... -> Desktop environment -> Generaland select Optimize working with large coordinates(Allplan 2009 and earlier: Tools -> Options -> Global Options -> Miscellaneous tab -> Optimize working with large coordinates). After this you must restart Allplan. Otherwise, this setting has no effect.

This is a user setting you must define separately for each user.

  • Usually, the best solution is to move the data towards the Allplan origin. Use the "Move" tool. When Allplan prompts you to specify the target point ("To point"), select Global point in the dialog line. You can find detailed information in the help for Allplan. Look for the Global pointtopic.



Note:

If the data are still not displayed correctly, do the following:
Exit Allplan -> Services application-> Service -> Hotline Tools-> cleanup -> start Allplan.

Download PDF  FAQ_EN_Large_coordinates.pdf
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 30.09.2020
 

Question:

I purchased the license server. How can I install and configure the license server?



Answer:

Allplan is using since version 2016 a new protection system. Licensing is based on CodeMeter by Wibu Systems AG since then. You can no longer use NemSLock Server with Allplan 2016 and higher.

Allplan requires a Product Key. Using this key, you can activate your license online. The Product Key is a unique, 26-digit character string. You can use it to activate a license for Allplan.
You can find your Product Key in Allplan Connect. Go to http://connect.allplan.com/license
Note: The license is downwards compatible til version Allplan 2016-1-4 even if a higher version is displayed.



To install the license server, download the software for the license server from Allplan Connect
or from our FTP server:
ftp://nemhotline:ha37jvg8f@ftp.nemetschek.de/download/Allplan/Lizenzserver/2017/DoWn-License_Server_Setup.zip

The Wibu license server is part of the CodeMeter driver, which is installed along with Allplan. If you have already installed Allplan on the license server, you do not have to install additional software. But you can also install the license server separately; you do not have to install Allplan.
In any case, install and activate the license server before you install Allplan on the clients.

You can activate a license in online mode only if you have ...

  • Internet access
  • a Product Key
  • a license server license; you cannot use other licenses with the license server.




Installing the license server

  • You must install the license server on a 64-bit Windows system.
  • Start License Server Setup on the computer you want to use as the license server.
  • Click Install.
  • Start the license server by starting the License Settings program. Go to the License activation area, enter your Product Key and click Activate license.
  • If you have more licenses for the license server, enter the respective Product Keys and activate the licenses.
  • Afterwards, start CodeMeter Control Center.

To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen: enter Codemeter and press ENTER. A dialog box opens. Click WebAdmin at bottom right.

Or
Enter Localhost:22350in the address bar of your browser.

  • Select Configuration -> Server -> Access server in the Network server area and click Activate.
  • Click Apply.



Configuring the license server (optional)

You can use the CodeMeter WebAdmin application to administer the license server.
To start and stop the license server service, you can use CodeMeter Control Center.

  • CodeMeter Control Center -> Action -> Start or Stop CodeMeter Service


Access control
By default, all users on the LAN, who have installed the CodeMeter driver, can use a license from the license server.

  • Basic access control: you can enter a list of client computer names or IP addresses that are allowed to access the license server.
  • Advanced access control: you can specify global access rules (for all licenses) to control access to the licenses.


License tracking
To activate license tracking, you have to set the HKEY_LOCAL_MACHINE\SOFTWARE\WIBU-SYSTEMS\CodeMeter\Server\CurrentVersion\LogLicenseTracking registry entry to 1 and restart CodeMeter Service.

After having activated this key, you can use CodeMeter WebAdmin to create a report showing details about the licenses used over a specific period of time. To do this, open CodeMeter WebAdmin and go to the 'Server' - 'License Tracking' page. Select the period of time and the license for which you want to generate a report. Then click 'Create report'. If you click a single bar, you will get detailed analyses per day or per hour.

CodeMeter WebAdmin saves the reports to C:\ProgramData\CodeMeter\Logs.



Installing and configuring clients

Note for Version 2016: Install at least Allplan 2016-1-4 on the clients.

The license server license will be detected automatically on the network.
Install Allplan on the clients. When you are prompted to select the license file, click Use active license. Follow the installation instructions.

  • You do not need to activatethe clients.


Allplan automatically finds the license server on the local network. If you have not selected a license, Allplan automatically selects the first available license.

After having installed Allplan on the clients, you can use the 'License Settings' dialog boxto configure license selection.
Services application -> Utilities -> License settings

Areas:

  • License activation: this area is not relevant to clients taking their license from the license server.
  • License selection: use this section if you get the license from a license server or if you have several licenses and you want to select the preferred license.
  • Start as a viewer: click this button if you want to start Allplan as a viewer.



License selection

You can see the names of the available licenses with their seat numbers.
The 'Available' column indicates how many licenses are still available. Click the dropdown arrow to see a list of users currently working with a license.

Priority:
Select the check box in front of a license to select this license as a favorite. You can mark as many licenses as you want. Allplan will then prefer these licenses. Click to select one ore more licenses Allplan is not to use. If you do not select any license or if you have selected several favorites, Allplan will automatically use the first free license it finds.

Find license server automatically:
When you select this option, Allplan automatically detects a license server on the LAN. In some cases, such as VPN connections, Allplan may not be able to detect a server automatically. In this case, you can enter the server manually (see Additional server name).
Note: Only the Windows administrator can change this option.

Additional server name:
If 'Find license server automatically' is not active or Allplan has not automatically found a license server, you can manually enter the name or the IP address of the server. If 'Find license server automatically' is active, you can enter an additional server. After having entered the server name, click 'Update' to see the licenses of the license server. Use semicolons to separate several server names.


Note:

You can find detailed information on the license server in the License Settings help (F1 key).

Allplan communicates with the license server via TCP/IP. By default, communication is via Port 22350 unless you change the port in CodeMeter WebAdmin.

If a firewall is active on your computer, you must enable port 22350 for TCP and UDP. If the firewall filters in an application-specific manner, you have to enable the CodeMeter.exe license server service. You can find this service in the %Program Files (x86)%\CodeMeter\Runtime\bin Windows folder. Define the CodeMeter.exe service as an exception in the firewall. Some anti-virus programs also include firewall functions. If you are not sure, contact the manufacturer of the anti-virus program.

Download PDF  FAQ_EN_Installing_and_configuring_the_license_server...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 01.10.2020
 

Question:

A new computer is to replace the existing one.
How can I transfer the existing data and settings of the existing Allplan installation to the new computer?



Solution:

Please note that this solution only works with stand-alone versions.
Install the same version of Allplan on the new computer and transfer the data as follows:

1st - transferring the data:
Transfer the following folders from the old computer to the new one:
Project folder (PRJ)
Office standard folder (STD) and
User folder (USR)

You can determine the path to these folders on both the new computer and the old computer as follows:
Services application->Service->Hotline Tools->Showcfg: shows system variables ->OK
You can find the paths to the folders after PRJ, STD and USR.

2nd - transferring the toolbar configuration:
Export the configurations from the old computer by clicking View -> Toolbars -> Customize... -> Export...
You can then import the configurations to the new computer by clicking View -> Toolbars -> Customize... -> Import...

Download PDF  FAQ_EN_Installation_on_a_new_computer_with_data_tran...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 01.10.2020 10:44
 

Question:

How can I import data from an earlier version?



Answer:

You can import data from the last three Allplan versions.
Consequently, the following import operations are possible:

Target version <- import possible from version

2017 <- 2014
2016 <- 2013
2015 <- 2012
2014 <- 2011
2013 <- 2009
2012 <- 2008
2011 <- 2006
2009 <- 2005
2008 <- 2004
2006 <- 2003
2005 <- 17
2004 <- 16

We cannot guarantee that data created in older versions can be imported and edited. The conversion of older data may be incomplete, which may affect intelligent components in particular.


1. Archived data from an earlier version (not older than three previous versions):

There are two ways to convert the data to the current version:

  • Import the project backups created and archived using the
    Services application -> Data Backup -> Import -> Projects.
    After importing the projects, convert them by opening each project once.
  • Import the backups archived using the
    Services application -> File -> Restore documents of any version to &apos;...\Extern&apos;.
    The data are written to the external path.
    You can now process the converted data in ProjectPilot.



2. Archived data from an older Allplan version (older than three previous versions):

  • See whether you can use the approach described in step 1 to import the old projects.
  • If available, it is a good idea to install an old Allplan version. Import the backups created and archived into this old version and convert the projects using the Services application. If you have imported a complete project backup, convert the data by opening each project once. When finished, repeat this process with a newer version (up to three versions later) until the data are up-to-date.
  • If an old Allplan version is not available, you can also have the data converted by Allplan. Please note that this service is not free of charge. Please contact Technical Support -> support.de@allplan.com.




Notes:

  • You can convert the data of all projects at once. Read the following FAQ in Allplan Connect: https://connect.allplan.com/en/faqid/20090408124904.html
  • If enough hard disk space is available, you are advised to keep and maintain the projects so that Allplan automatically converts them to the current version whenever you upgrade.
  • If there are project-specific smart symbol catalogs, you should open the smart symbol catalog once to convert the data.
Download PDF  FAQ_EN_Transferring_data_from_old_Allplan_versions_....
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 01.10.2020
 

Question:

What are the differences between a major release, a service release and a hotfix?



Answer:

Major release

The major release is the first release of a new version.
You can download it from the homepage.

Download:
www.connect.allplan.com -> Download -> Software packages
(requires login details for Allplan Connect)

Name (example):
Allplan 2015


Service release

A service release is a collection of improvements to the program, including all the service releases and hotfixes that have been released until now. In addition to improvements, it may also include new features.
You can also use a service release for a new installation or an upgrade (from a previous version).
You can download it from the homepage.
New customers get it as a DVD. Serviceplus customers get it on request.
In addition, they automatically get information about service releases.

Download:
www.connect.allplan.com -> Download -> Software packages
(requires login details for Allplan Connect)

Name (example):
Allplan 2015-1


Hotfix

A hotfix is an improvement to the program that will automatically be installed by Allplan Update.
The basis for the installation is a specific major release or service release.
Hotfixes are installed one after the other in the correct order, that is to say, first Hotfix 2015-1-1 and then Hotfix 2015-1-2.

Allplan automatically installs available hotfixes when it starts.

You can find more information on hotfixes in the following FAQ:
https://connect.allplan.com/en/faqid/20101203111503.html




Tip:

Install program updates as soon as they are available.

Download PDF  FAQ_EN_Program_updates.pdf
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014  | Last modified: 30.09.2020
 

Question:

How can I check out a computer and continue to work as a normal CAD user with my usual settings and permissions?



Answer:

Install the "Microsoft Loopback Adapter" driver.
This driver is necessary so that network services are running on the computer all the time.
Go to Allplan Connect for a detailed description: https://connect.allplan.com/en/faqid/000162ae.html


Sign in as the Allplan administrator to the computer.


Step 1: add the computer to workgroup manager
You must add the computer to the workgroup so that you can store data (data server) on this computer. Do the following:

Create data folders:
Create a folder - for example, “Nemdata” - on the computer and share it (full control).
Create the “Allplan” subfolder in this folder. Create two subfolders - “usr” and “prj” - in the Allplan folder.
In this example: “...\Nemdata\Allplan\prj” and “...\Nemdata\Allplan\usr”

To share a folder for the Allplan file storage

  1. Start File Explorer on the computer that you want to use for file storage and switch to the folder that you want to share (in this example, the “Nemdata” folder).
  2. Right-click the folder that you want to share and select Give access to -> Specific peopleon the shortcut menu.
  3. Select Everyoneand click Share.


Add computer:

  1. Start the Services application as the workgroup administrator.
  2. Click and select Manage computers and projects.
  3. Click the Add any computer to Allplan workgroupicon and select the computer that you want to add.
  4. Select the “Allplan” subfolder under the share and click “OK” to confirm. This computer is now listed under workgroup server.


Note:If you have problems adding the computer to workgroup manager, read the following instructions:
https://connect.allplan.com/en/faqid/20200317162849.html



Step 2: define project owner
A user can only move a project if the user is the owner of this project.
The ownership of a project can only be changed by an Allplan administrator (or the owner of the project).
Allplan -> File -> ProjectPilot ->
Go to the “Projects” node, right-click the required project and click Propertieson the shortcut menu.
Define the owner.


Step 3: move projects
Sign in as the user who wants to check out the computer.
Select the Services application -> Workgroup Manager -> Manage computers and projects.
Click the main server and select the project that you want to move.
Drag the projects one after the other to the computer to be checked out.

Important note: You can take projects with you in several ways.

1. You move the project to the computer.
Move project: Drag the project to the destination computer, or open the shortcut menu of the project and click “Cut”. After this, open the shortcut menu of the destination computer and click “Paste”.
After you have checked in the computer, move the project back to the server so that it is available to all and included in backups again.

2. You copy projects. Click a project, select and hold the Ctrl key and drag the project to the destination computer. Or: Open the shortcut menu of the project and click “Copy”. After this, open the shortcut menu of the destination computer and click “Paste”.

You can continue in two ways: Lock the original project on the server to protect it from changes. Consequently, nobody in the office can work on this project, but it is still on the server. When you check in the computer again, you unlock the project on the server, delete the project and copy your copy back to the server if you have changed the project.
Alternatively, both projects remain active. Consequently, both the project copied and the original on the server can be worked on. In this case, however, you must adjust the data manually when you are back in the office by copying the changed drawing files of the projects by using ProjectPilot.




Step 4: check out the computer
Select the Services application -> Workgroup Manager -> Manage computers and projects.
Click your computer and then click Check outin the lower-right area.
Confirm the message that tells you that there are still user folders on the computer to be checked out.
Enter a comment and click OK. Users in the office see this comment when they try to access a project that is on the computer that is checked out.
Specify the parts of the office standard you want to copy to the computer and click OK to confirm.
The first time you check out the computer, you must copy the office standard once so that the entire STD folder is on this computer. This is no longer necessary when you check out the computer afterward because the contents of the STD folder do not change very often.


Conclusion:

You can now remove the computer from the network and work on your projects when you are out of the office. To make sure that the projects are not changed in the office in the meantime, the projects that are on the computer checked out are locked for the CAD users on the network. These users see the comment you entered when you checked out the computer.



Notes:


Download PDF  FAQ_EN_Workgroup_Manager_checking_out_computer_and_w...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 12.11.2020
 

Question:

Which graphics cards are recommended for Allplan?



Answer:


Follow this link to see a list of the AMD/ATI & NVidia graphics cards manufacturers that are CERTIFIED FOR ALLPLAN.
We have tested the OpenGL functionality and the animation performance of various Allplan modules with specially prepared data with each of the cards available.
https://www.allplan.com/services/cad-software-support/grafikkarten.html

The tested drivers can be found on the homepage of the individual manufacturer. The driver versions that were used in the tests are included in the tables so that you can compare the data. However, we strongly recommend that you always installthe current driver of the manufacturer.

It is a good idea to check your system using the system tool you can find on our homepage:
https://www.allplan.com/services/cad-software-support/downloads.html



Additional information:

Allplan 2011 was revised completely for accelerated graphical representation.
To guarantee full performance support for Allplan 2011 and later, please check that your graphics cards meet the hardware requirements for DirectX 10 & OpenGL 2.0 (chip-based). In addition, you need to install the current drivers. Allplan will automatically switch to the conventional drawing method when it starts and finds old graphics cards that do not meet the requirements stated above.

For more information on graphics card specifications, go to

http://en.wikipedia.org/wiki/Comparison_of_AMD_graphics_processing_units
http://en.wikipedia.org/wiki/Comparison_of_NVIDIA_graphics_processing_units#Quadro)



Note:

We kindly ask you to understand that products of other manufacturers that are not mentioned have not been tested and therefore cannot be recommended.

Download PDF  FAQ_EN_Recommended_graphics_cards_for_Allplan.pdf ...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017  | Last modified: 20.01.2021
 

Question:

You would like to know which colleague has borrowed a license from the license server and for what period of time it was borrowed?


Answer:

Prerequisite:
Please make sure that at least Codemeter version 6.60b is installed on the license server.
To do so, start the CodeMeter Control Center on the server
Either in the Windows Start menu via CodeMeter -> CodeMeter Control Center. Or enter Codemeter in the search bar of the start page and press ENTER. Under Help-> About you can see the installed Codemeter version. If a version lower than 6.60b appears here, install the latest version of the Control Center released by Allplan. Instructions on how to do this can be found at the following link https://connect.allplan.com/de/faqid/20160113131406.html


Application:
The administration of the license server is done via the CodeMeter WebAdmin application on the server itself.
Start the CodeMeter Control Center at the license server on the server
Either in the Windows Start menu via CodeMeter -> CodeMeter Control Center. Or in the search bar of the start page enter Codemeter
and press ENTER, then click WebAdmin in the dialog box at the bottom right.

Or:
Type Localhost:22350 in the address bar of your browser.

In WebAdmin go to Container -> All Containers -> here select your Allplan Cm6 in which your license/s have been stored -> select the desired license by clicking on the Product Code 999 in front of it. -> Now scroll down to the end, to the License Transfer History area.

Here you can see exactly when the license was borrowed, for how long and by which user.


Hints:
If you want to see which users are currently in the network pulling licenses from the license server, you can also see this. To do this, go to License Monitor-> Sessions in WebAdmin.

Borrowed licenses are currently only displayed with the container number under License Monitor-> Sessions, only under License Transfer History the user is also visible.

Since under License Transfer History it is a complete history, all license loans are listed, even those that have already been terminated, i.e. the license has been returned to the license server in the meantime.

Download PDF  FAQ_EN_License_server_-_license_borrowing_tracking_w...
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012  | Last modified: 30.01.2020
 

Task:

You have installed Allplan on several local workstations. Now you want to change the installation so that you can access a common network drive.



Note:

Before you switch to a network installation, it is essential that you back up all the data of all the workstations.
We strongly recommend that you take advantage of the expertise of Nemetschek’s technical support staff. We are happy to help you!



Solution:

The following description shows how to change several workstations where Allplan is installed locally and the project data is also stored locally on each computer to workstations with a common network drive without Workgroup Manager.

1st - getting ready
Choose one of the workstations where you will install all the projects and the office standard (hereinafter referred to as the main workstation).
First, move all the projects to the main workstation.

1.a: copying resources into projects
To make sure that the projects in your office have a uniform appearance, change the path settings for the projects&apos; resources to &apos;Project&apos;.
Make the following setting for each project:
Allplan -> File menu -> ProjectPilot - Admin -> select the individual projects one after the other -> right mouse button -> Properties -> Settings tab
Set the path settings for &apos;Pen and line definitions&apos;, &apos;Fonts&apos;, &apos;Patterns, hatching styles, area styles&apos;, &apos;Bar and mesh cross-section catalogs&apos;, &apos;Layer structures, line styles, drawing types&apos; and &apos;Attributes proposed&apos; from &apos;Office&apos; to &apos;Project&apos;, if necessary.
The corresponding elements are copied from the office standard directly to the project. This ensures that the project settings stay the same even when you copy the project to the new server with the new office standard.

1.b: same folder name as project name
Open the &apos;General&apos; tab and select the &apos;Same folder name as project name&apos; setting if you want to proceed as described in 2b.

1.c: pen color ("Color stands for pen")
The pen color for the "Color stands for pen" setting is a user-specific setting that is not saved in the project but in the user folder (...\Usr).

2.a: backing up projects of the individual workstations and importing them to the main workstation (recommended method):
Back up the individual projects. To do this, open the Services application and select Data Backup -> Create -> Entire folders -> Projects.
You can back up several projects in a single operation.
Before you start, specify the backup folder on the network or on the local hard disk: Services application -> Configuration -> Backup path ->Browse for Folder.

The next step is to import the saved projects to the main workstation.To do this, open theServices application -> Data Backup -> Import -> Projects Before you import the individual projects, you can create new Allplan projects at the main computer. As an alternative, you can also create a new project during the import.

2.b: backing up projects of the individual workstations and importing them to the main workstation (special approach):
This approach should only be used with good reason for exceptional cases as it requires in-depth knowledge of Windows.
With this method, Windows Explorer is used to import the projects to the main workstation.
If some project names exist twice, you need to rename these projects before you back them up.

You can then rename the existing &apos;project.dat&apos; file in the Prj folder of the main workstation.
Next, select the Services application -> Service -> Hotline Tools -> reorg -> Restore project management file.
The system creates a new project administration file (project.dat), which should list all projects with names.

Now the main workstation contains the latest version of all the projects of the office.

3rd - merging project defaults
Open ProjectPilot at the individual workstations and copy the elements you want to transfer (symbols, smart symbols, lists, schedules, and so on) to the external path. Of course, you can set the external path to a common network folder that can be accessed by all workstations.
Next, open ProjectPilot at the main workstation and copy the contents of the external path to the office standard.

4th - data backup

  • Back up the projects, office standard and user settings at the main workstation:
    You can also copy the ..\prj (projects), ..\std (office standard) and ..\usr (user folder) paths to a backup folder (Nemsic, for example) on the hard disk.
  • In addition, you need to back up the ..\usr\local folder at every stand-alone computer.
  • Export the user interface setting of each user to a file: Allplan -> Tools - > Customize .... -> Export...


5th - uninstalling
Remove Allplan from all workstations.

6th - reinstalling
Before you install the same version again, create and share a folder (Nemdata, for example) on the future data server. Create a subfolder - Allplan - in this folder.

The next step is to reinstall the same version on all the workstations.

Specify the following installation paths:
Program folder:
local (C:\Programs\Nemetschek\Allplan, for example)
Central file storage folder:
Browse -> Network...
Find the sharedNemdata folder and select the Allplan folder.

After this, start installing.

7th - testing the start and restoring the backup
After the installation (check whether Allplan starts), copy the ..\prj and ..\std folders you backed up from the main workstation to the new ...\Nemdata\Allplan server folder.

Next, use Windows Explorer to copy the contents of the former user folder (…\usr\local) of the stand-alone workstation to the new user folder of the computer you just installed.

8th - updating the project administration file
Go to the project.datfile in the ...\Nemdata\Allplan\Prjfolder and rename itproject.alt.After this, do the following:
Services application -> Service -> Hotline Tools -> reorg -> Restore project management file.

9th - summary
Now all the workstations access a common network drive with the same project pool and office standard.
With this type of installation, only one user can access a project at any one time. If several users are to work on a project at the same time, you need to install Workgroup Manager.

Download PDF  FAQ_EN_Switching_from_single_installation_to_network...
1 - 10 (25)
https://campus.allplan.com/ uses cookies  -  More information