Результат поиска

1 - 10 (14)
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 30.09.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

Suddenly, one of the following error messages pops up: "This license is no longer available", "CmActLicense runtime system is not installed!" or "NemAll_DataResource20.dll: Start Error 102". After this, Allplan does not start anymore. How can I solve this problem?


Answer:

The local Windows service, which is used by licensing, is not running correctly.

If communication with the local Wibu service is blocked, Allplan cannot find the license anymore. This is often caused by the virus scanner.
So you need to exclude the "Codemeter" folder from virus scans.
You can find this folders in the following path:
C:\Program files (X86)\Codemeter
C:\Program files\Codemeter
C:\ProgramData\CodeMeter

Then restart the service:

Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.

CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.



Important note:

Follow this link to find out how to configure the virus scanner in conjunction with real-time scanning. Exclude all Allplan folders with their subfolders from virus scans. You can display the paths to the Allplan folders in the Services application window.

https://connect.allplan.com/en/faqid/20091126145752.html


Загрузка PDF  FAQ_EN_Windows_service_for_licensing_is_blocked_by_v...
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 01.10.2020
1 user(s) found this FAQ helpful

Question:

I cannot activate Allplan. When I enter the Product Key, the "no Internet connection" message appears even though the computer is connected to the Internet. Which ports are required? Are there any settings for the proxy server?


Answer:

License activation accesses the internally used URLs

https://lc.codemeter.com/59885/gateways/getLicenses.php and
https://lc.codemeter.com/59885/gateways/getTicketInformation.php.

Make sure the proxy server does not block these URLs.
Try to activate the license again.

Загрузка PDF  FAQ_EN_License_activation_-_no_Internet_connection_w...
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 20.11.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

During installation of license server the message appears 'installation failed'. What could be the reason for it?



Answer:

Check the following points:

  • The license server must be installed in a 64 bit windows system. License server is not working on 32 bit system.
  • Make sure the license server setup is saved local on the machine and is not executed over network
  • Stop the real time check of your virus scanner or stop the virus scanner complete during installation. Optionally stop the firewall as well - attention in most cases you have to reboot the server in order to take over the settings.
  • Run the *.exe file over context menu -> run as administrator.
  • If the license server installation still fails. The reason could be NET framework. License server uses NET framework 4.6 and in newer version 4.7. If there are components missing the setup will automatically try to install them. This happens in the background. It will be connected to webpage of Microsoft http://go.microsoft.com/fwlink/?LinkId=397708 and the missing files will be downloaded and installed. If a proxy server is blocking this page the download cannot happen and the license server installation fails. In these cases you will have to configure the proxy server settings to allow the Microsoft URL. Microsoft URL has to be trustworthy. Start installation of license server again.



Addition for license server 2017 on older sever like 2008 R2 server:

If the license server installation still fails and the setup stays at 50%, then the reason is usually .NET framework.
Try to install the .NET version in advance from Microsoft Download.


Installation of. NET framework 4.6 requires at least Windows Server 2008 R2 with SP 1.
For information, also see the following link: https://www.microsoft.com/de-de/download/details.aspx?id=49982


If the installation of the new version keeps failing, try to install a slightly older license server.
It will works the same way with ALLPLAN 2017 but still is operating with .NET 4.5.2.
Use the following link:
ftp://nemhotline: ha37jvg8f @ftp.nemetschek.de/download/Allgemein/Archiv/WiBu/Lizenzserver
Download the License server until 2017-0.

Note:

After successfully installation of license server you will have to connect via internet again in order to activate the license. If using proxy allow the access of the following URLs as well.

https://lc.codemeter.com/59885/gateways/getLicenses.php

https://lc.codemeter.com/59885/gateways/getTicketInformation.php

Загрузка PDF  FAQ_EN_License_server_installation_failed.pdf
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Последнее изменение: 01.10.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

Internet connection exists on your computer and the settings used for the proxy for the URLs you have set also. You try to activate your license with your product key, but the activation could not be performed. You get the message ' server not found error'. How can the license be activated yet?

Reply:

License activation:

The following description is valid for single user license as also license server licenses.

Try to activate the licenses on the computer/server via the following website online.
This Web site must be launched directly on the computer on which the license should be enabled.


http://lc.codemeter.com/59885/depot/index.php

In the row "Ticket", enter your Product Key and click continue your license will be displayed, click on activate license now.

Note: (only for license server license)
A selection appears asking for the binding of licenses.
Select firm code 6000100 on the right hand side.
'I want my licenses on one computer (CmActLicense). Firm code: 6000100 CmContainer ALLPLAN CM6 (2000)'

Sometimes multiple rows for the same license will be displayed (E.g. license number and a -u behind it) please leave all licenses checked and click on Activate selected licenses now.

The transfer of the license starts now. When activation is finished your license on this page should now appear with status activated.

If the problems with license activation occurred during the installation of ALLPLAN, cancel to exit Setup and restart the installation of ALLPLAN again. Then select in the Setup license configuration use active license now and the installation can continue.

Then open the license setting over services -> utilities-> license settings.
Or license server via License Settings.

Click on the left side on license selection. Now the license is displayed under the computer name.

License return:

This Web site must be launched directly on the computer on which the license should be enabled.


http://lc.codemeter.com/59885/depot/index.php

In the row "Ticket", enter your Product Key and click continue your license will be displayed, click on re-host license now.

Sometimes multiple rows for the same license will be displayed (E.g. license number and a -u behind it) please leave all licenses checked and click on Re-host selected licenses now.

The transfer of the license starts now.

Notes:

  • Sometimes the license is not displayed under license activation, because it has been enabled via the website.
  • If you want to remove the licenses, you must do so via the website again.
Загрузка PDF  FAQ_EN_License_activation_returning_is_still_not_pos...
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014  | Последнее изменение: 27.10.2020
1 user(s) found this FAQ helpful

Question:

I can neither check in nor check out the computer.
When I try to check in the computer, the following error message appears: “The registry entries are not correct!” How can I correct this error?


Answer:

There is a hidden file on the server. This file causes the problem, which is probably related to user rights or user account control.

You have to change the settings directly on the server, that is so say, you have to use the folder options to show all hidden folders and files.

1. Open the central file storage folder on the server. There is a subordinate folder called
NET. This folder contains the computer_name.out file. Here, computer_name is the name of the computer that is checked out.
Delete this file.

2. Open the shared folder (for example, C:\Nemdata\Allplan) on the computer that is checked out.
Allplan 2015 and earlier: Delete the Net.ChkOutfolder.
Allplan 2016 and later: Delete the NETfolder.

Now the computer is checked in again. Consequently, you can move projects to this computer
or check it out once more.


Note:

If the computer or the projects are still red, you have to fix the projects.

To fix the projects:
Services application -> Workgroup Manager -> Administer projects and computers

Do the following:

Ctrl + right-click computer
-> can be checked in
Ctrl + right-click project-> can be unlocked

Repeat this step to unlock every project on the computer.
When you have finished, close the dialog box and open it again to update it.
Now everything should be correct.

Загрузка PDF  FAQ_EN_Workgroup_Manager_Problems_when_checking_in_o...
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2017 / Allplan 2016 / Allplan 2015  | Последнее изменение: 12.06.2020
1 user(s) found this FAQ helpful

Question:

What can I do if Allplan no longer starts after I have upgraded and the following messages appear?
Allplan
Stop

...

After this, Quality Reporter displays an error report.



Answer:

Exit Allplan on all workstations and do the following:
Open the Services application and make a note of the path to the 'central file storage folder', which is displayed in the Services application window.
In addition, check whether the workgroup manager line is followed by 'Yes' or 'No'.

Open the central file storage folder in Windows Explorer.

If the workgroup manager line is followed by
'Yes', open the NET subfolder.
'No', open the PRJ subfolder.

Find the 'project.dat' or 'project.Dat.xm' file in the NET or PRJ folder and rename it 'project-old.dat'.

After this, do the following:
Services application -> Service -> Hotline Tools -> reorg -> OK -> Restore project management file -> OK
The program creates a new, correct project management file and you can start Allplan again.



Note:

If you come across error messages while doing this, please email the following information to support@allplan.com:

  1. Describe exactly what you did before the error or crash occurred.
  2. The error message itself (as a screenshot).
  3. The log file (trace).
    https://connect.allplan.com/en/faqid/0001a27a.html
  4. A Hotinfo support request with question 01.
    https://connect.allplan.com/en/faqid/20130823123806.html
Загрузка PDF  FAQ_EN_Allplan_does_not_start_after_upgrade_Stop_mes...
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018  | Последнее изменение: 17.07.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How can Allplan be operated under a QHD / UHD / 4K resolution?


Answer:


Starting with Allplan 2018, a query will appear in the Allplan Start under a QHD / UHD / 4K resolution (from 2560 x 1600), in which you can decide whether the operating system scaling should also be used in Allplan. This choice can be changed at any time in the Allplan Options-> Desktop Enviroment- > Display-> Scaling of the user interface.

Note:

If this option is switched on, Allplan uses the scaling level, which is set globally in the display settings of the operating system. Side effects of this scaling can be slight blurring in the symbols, drawing elements, and dropped graphics in Allplan.
Please note that this functionality is only available from Windows 8.1 and higher.

Загрузка PDF  FAQ_EN_Notebooks_and_screens_with_QHD_UHD_4K_resolut...
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012  | Последнее изменение: 30.01.2020
1 user(s) found this FAQ helpful

Task:

You have installed Allplan on several local workstations. Now you want to change the installation so that you can access a common network drive.



Note:

Before you switch to a network installation, it is essential that you back up all the data of all the workstations.
We strongly recommend that you take advantage of the expertise of Nemetschek’s technical support staff. We are happy to help you!



Solution:

The following description shows how to change several workstations where Allplan is installed locally and the project data is also stored locally on each computer to workstations with a common network drive without Workgroup Manager.

1st - getting ready
Choose one of the workstations where you will install all the projects and the office standard (hereinafter referred to as the main workstation).
First, move all the projects to the main workstation.

1.a: copying resources into projects
To make sure that the projects in your office have a uniform appearance, change the path settings for the projects' resources to 'Project'.
Make the following setting for each project:
Allplan -> File menu -> ProjectPilot - Admin -> select the individual projects one after the other -> right mouse button -> Properties -> Settings tab
Set the path settings for 'Pen and line definitions', 'Fonts', 'Patterns, hatching styles, area styles', 'Bar and mesh cross-section catalogs', 'Layer structures, line styles, drawing types' and 'Attributes proposed' from 'Office' to 'Project', if necessary.
The corresponding elements are copied from the office standard directly to the project. This ensures that the project settings stay the same even when you copy the project to the new server with the new office standard.

1.b: same folder name as project name
Open the 'General' tab and select the 'Same folder name as project name' setting if you want to proceed as described in 2b.

1.c: pen color ("Color stands for pen")
The pen color for the "Color stands for pen" setting is a user-specific setting that is not saved in the project but in the user folder (...\Usr).

2.a: backing up projects of the individual workstations and importing them to the main workstation (recommended method):
Back up the individual projects. To do this, open the Services application and select Data Backup -> Create -> Entire folders -> Projects.
You can back up several projects in a single operation.
Before you start, specify the backup folder on the network or on the local hard disk: Services application -> Configuration -> Backup path ->Browse for Folder.

The next step is to import the saved projects to the main workstation.To do this, open theServices application -> Data Backup -> Import -> Projects Before you import the individual projects, you can create new Allplan projects at the main computer. As an alternative, you can also create a new project during the import.

2.b: backing up projects of the individual workstations and importing them to the main workstation (special approach):
This approach should only be used with good reason for exceptional cases as it requires in-depth knowledge of Windows.
With this method, Windows Explorer is used to import the projects to the main workstation.
If some project names exist twice, you need to rename these projects before you back them up.

You can then rename the existing 'project.dat' file in the Prj folder of the main workstation.
Next, select the Services application -> Service -> Hotline Tools -> reorg -> Restore project management file.
The system creates a new project administration file (project.dat), which should list all projects with names.

Now the main workstation contains the latest version of all the projects of the office.

3rd - merging project defaults
Open ProjectPilot at the individual workstations and copy the elements you want to transfer (symbols, smart symbols, lists, schedules, and so on) to the external path. Of course, you can set the external path to a common network folder that can be accessed by all workstations.
Next, open ProjectPilot at the main workstation and copy the contents of the external path to the office standard.

4th - data backup

  • Back up the projects, office standard and user settings at the main workstation:
    You can also copy the ..\prj (projects), ..\std (office standard) and ..\usr (user folder) paths to a backup folder (Nemsic, for example) on the hard disk.
  • In addition, you need to back up the ..\usr\local folder at every stand-alone computer.
  • Export the user interface setting of each user to a file: Allplan -> Tools - > Customize .... -> Export...


5th - uninstalling
Remove Allplan from all workstations.

6th - reinstalling
Before you install the same version again, create and share a folder (Nemdata, for example) on the future data server. Create a subfolder - Allplan - in this folder.

The next step is to reinstall the same version on all the workstations.

Specify the following installation paths:
Program folder:
local (C:\Programs\Nemetschek\Allplan, for example)
Central file storage folder:
Browse -> Network...
Find the sharedNemdata folder and select the Allplan folder.

After this, start installing.

7th - testing the start and restoring the backup
After the installation (check whether Allplan starts), copy the ..\prj and ..\std folders you backed up from the main workstation to the new ...\Nemdata\Allplan server folder.

Next, use Windows Explorer to copy the contents of the former user folder (…\usr\local) of the stand-alone workstation to the new user folder of the computer you just installed.

8th - updating the project administration file
Go to the project.datfile in the ...\Nemdata\Allplan\Prjfolder and rename itproject.alt.After this, do the following:
Services application -> Service -> Hotline Tools -> reorg -> Restore project management file.

9th - summary
Now all the workstations access a common network drive with the same project pool and office standard.
With this type of installation, only one user can access a project at any one time. If several users are to work on a project at the same time, you need to install Workgroup Manager.

Загрузка PDF  FAQ_EN_Switching_from_single_installation_to_network...
Версия:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018  | Последнее изменение: 30.09.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

You want to include a computer in the Allmenu via Workgroupmanager, but no network environment is displayed and no result appears when you enter the computer name in Search. How can the computer still be included?



Answer:

All computers included in the Workgroupmanager are stored in the data.cfg on the server in the central file storage request.
The Allmenu window shows the exact path of the "central file storage folder".

e.g. \\SERVER\data\Allplan
Go via Windows Explorer to the central file storage folder in the NET folder and open the file data.cfg (e.g. with the editor)

The content of the file looks like this
SERVER \data\Allplan

(So far no computer has been included and therefore there are no further entries in this example)

Here you can enter the new path of the computer to be recorded
Simply enter the computer name, spacebar, shared folder, subfolder as a new line.
Enter only your simple host name here, not the FQDN name (first name only, without periods and other additions)

Please make sure that all entries are flush with each other. Please do not remove the space bars in existing entries and also insert a space bar after the host name when entering, these are important.

So it looks like this

SERVER \data\Allplan
COMPUTERNAME \Nemdata\Allplan

Save the file.

As a result, the computers in the workgroup are displayed in the Allmenu/Services application under Workgroupmanager - > Administer projects and computers and can now be checked out.

Загрузка PDF  FAQ_EN_Workgroupmanager_Adding_the_computer_is_not_p...
Версия:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017  | Последнее изменение: 25.11.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

Whenever I try to create a project, the New Project, Open Projectdialog box does not open.
If I try to open ProjectPilot, the following message appears:Unable to create ProjectPilot control.What can I do?



Answer:

Some important entries are not defined in the Windows Registry.

Close Allplan and do the following:

Services application -> Service -> Windows Explorer -> CAD program folder -> PRG

Find the NemProjectPilot10.exefile and start it as the administrator. To do this, right-click this file -> Run as administrator.
Start Allplan and open ProjectPilot by clicking File -> ProjectPilot. Then create a new project.
After this, open New Project, Open Project. This should work without problems.



Note:

You require administrator privileges to write to the registry.