Question:

The windows for options and the window for IFC import and export are closed immediately when opened. How can this issue be solved?



Answer:


1. HP computer

If you are using an HP (Hewlett-Packard) computer, please take these steps. Otherwise proceed to number 2.

Check whether the security software "HP ProtectTools" is installed on this computer. If yes, then uninstall "HP ProtectTools". This software suite consists of several progams. In most cases, these programs are:

  • HP ProtectTools Device Access Manager
  • Embedded Security for HP
  • Face Recognition for HP ProtectTools
  • File Sanitizer For HP ProtectTools
  • Privacy Manager for HP ProtectTools
  • Theft Recovery
  • Drive Encryption for HP ProtectTools
  • HP ProtectTools Security Manager



It is possible that more or less HP software than the listed is installed. When you uninstall the "HP ProtectTools Security Manager", no other dependent software should be listed during uninstallation.

If there is dependent software listed during uninstallation, please uninstall these programs first. As the last step, "HP ProtectTools Security Manager" should be uninstalled.

An example message, listing dependent software which is still installed:




Important notice: Please restart the computer to complete uninstalling the software.




2. Dell computer

If you are using a Dell computer, please take these steps. Otherwise contact the Allplan support.

Check whether the security software "Dell Data Protection" is installed on this computer. If yes, then uninstall "Dell Data Protection". This software suite consists of several progams. In most cases, these programs are:

  • Dell Data Protection | Security Tools Authentication
  • Dell Data Protection | Security Tools


It is possible that more or less Dell software than the listed is installed. When you uninstall the "Dell Data Protection", no other dependent software should be listed during uninstallation.

If there is dependent software listed during uninstallation, please uninstall these programs first. As the last step, "Dell Data Protection" should be uninstalled.

An example message, listing dependent software which is still installed:




Important notice: Please restart the computer to complete uninstalling the software.




Notes:

HP ProtectTools Security Suite was developed by McAfee in cooperation with HP. It is pre-installed on most HP business notebooks and on some HP desktop computers.

HP ProtectTools are using Full Volume Encryption (FVE) by McAfee Safeboot, which changes the Win32 API behaviour. This causes problems in Allplan.

Also Dell is using similar mechanisms for the Dell Data Protection Suite. They have the same influence on Allplan.

Please note that these programs in either case have negative effects on stability and functionality of Allplan, even if you might not notice it (example: working options and IFC windows in different Allplan version).


Download PDF  FAQ_EN_Options_window_IFC_window_closed_immediately_...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014  | Last modified: 30.09.2020
1 user(s) found this FAQ helpful

Task:

Several users require Allplan administrator privileges in an installation with Workgroup Manager.



Note:

There are normal users and Allplan administrators in Allplan installations with Workgroup Manager.
Allplan administrators are:

  • Windows users with any login name who are granted administrative rights in the Workgroup Manager administration.

In other words, a Windows user with Windows administrator privileges does not necessarily have to be an Allplan administrator at the same time.

We do not recommend that several users work with Allplan administrator privileges at the same time, making it difficult to manage and protect the office standard, that is, the global settings. See solution 1.

However, if it is essential that several users are Allplan administrators, see solution 2.


Solution 1:

There is one Allplan administrator and normal Allplan users.

As the owner of a project has advanced rights in this project, you can define a user as the owner in a project and set the required resources to 'project'.
File -> New Project, Open Project... -> right-click the project you need -> Properties ... -> Path settings
Set the required resources to project.
You can also make these settings when you create a project or in ProjectPilot.

In addition to the Allplan administrator, another user (the owner of the project) can now define settings in the project.

Notes:

  • There are two standards for the definitions set to project: office and project.
  • It is only the Allplan administrator who can make changes in the office standard.



Solution 2:

Windows users with any login name are set up as Allplan administrators.


First, set up the Windows user as an Allplan user.
Services application -> Workgroup Manager -> Administrate users -> right-click->Create user

For the "user name", you can enter any Allplan user name, which can be up to 8 characters long.
For the "Windows user name", you must enter the name the user uses for login.
Important: If the user uses a domain for login, you must add it to the "Windows user name", for example, DOMAIN\user.

Grant the administration privilege to the "user group":
select "Administrator"on the dropdown menu. Using this approach, you can also assign the administration privilege to existing users.

Important: Click "Apply" and then "OK" to close the dialog box and the user overview, respectively.

Download PDF  FAQ_EN_Several_users_with_Allplan_administrator_priv...
Version:  Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 14.02.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

Allplan starts as a viewer. What can I do?



Answer:

Do the following:

1. The Allplan license folder contains the servcfg.nse file.

Open this folder:
Services application -> Service -> Windows Explorer -> General program data (ETC, LIC) -> License.

Delete the servcfg.nse file from this folder.

2. Install the new, appropriate license, which you can find in the attached file. Save the license to a folder on your computer and install it as follows:
Services application -> Utilities -> License -> Install HARDLOCK License

3. Check that the light indicator of the connected USB dongle (blue or white stick) is on all the time. To test it, you can connect the dongle to a different port.

4. Install the current hardlock driver if the light indicator is off.
You can find detailed instructions here:

https://connect.allplan.com/en/faqid/20131028125253.html

5. Select the Services application -> Utilities -> License -> License settings -> Licenses.
Check if "Allplan FT" is displayed in the white window on the left. If this is so, Allplan has accepted the dongle.

If this is not so, send the logmes.nse file, info.001 file and the new servcfg.nse file (license folder) to support.de@allplan.com


Download PDF  FAQ_EN_First_steps_to_solving_hardlock_license_probl...
Version:  Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011 / Allplan 2009  | Last modified: 22.01.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How can I remove NemSLock completely from a computer?



Answer:

Do the following:

  1. Uninstall Softlock 2006 by clicking Start -> Control Panel -> Programs and Features.

  2. Select "Nemetschek SoftLock 2006" and then click "Uninstall/Change". Select "Remove" -> Next -> Yes.
  3. Extract the "NSLFixer2006.zip" file attached and copy it to any folder on your computer. If your email provider or firewall software has blocked this file, you can also download it from our webdrive. Use this link:

    https://webdrive.allplan.com/index.php/s/4LrjrymoxESzC6p

    The tool "NSLFixer2006.exe" is under Allgemein/Nemslock

    (click on the right hand side next to file size on the three dots and chose 'herunterladen')

  4. Start NSLFixer2006.exe by double-clicking it.
    Important note:
    If you are running Windows Vista or a newer operating system, click the program with the right mouse button and select "Run as administrator". Confirm the following message.
  5. Create the key by clicking "Generate/Enter a key" (1).

  6. Select the line to the right of "Generate/Enter a key" (2), "1F02E74917D3F6E7348C1F02E74917D35E2599A254864A233C549A25ADD2EDFD", for example, and press "Ctrl+C". Paste this key into an email and send it to "support.de@allplan.com".
  7. We will send you another key. Please copy this key to the second line (3). If you need to restart the program, paste the key you created into the first line (see step 3, do not click "Generate/Enter a key" again!). Then click "Validate twin key" (4). After you have done this, you should see the following message: "System cleaned. Reinstall NemSLock".
  8. Update your current Allplan version. Use the temporary license file ("psd" can be found in its file name). You can also find your current temporary licenses at www.connect.allplan.com. Go to "Profile -> License administration".
    Students should use the Allplan Setup program which they can download from Allplan Campus (http://www.allplan-campus.com -> log on -> select "Software" at the top -> download Allplan). Use the trial license provided by Setup.



After this, request a new license by sending a new registration request (Services application -> Utilities -> License -> License Manager). Select the license entry for your seat and click "Request license".
If you work with a license server, reconnect the client with the server.

Download PDF  FAQ_EN_Removing_NemSLock_completely.pdf Download NSLFixer2006_EN.zip
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017  | Last modified: 16.10.2020
1 user(s) found this FAQ helpful

Question:

How can I install additional Allplan workstations on an existing network (with or without Workgroup Manager)?



Answer:

Before you install the additional workstations, find out the path to the central file storage folder on a computer where Allplan has already been installed. Open the Services application on this computer. The Services application window shows the path to the central file storage folder.

Enter this path when Setup prompts you to specify the central file storage folder.
Select "Minimum" for the Setup type.



Notes:

  • Make sure the version you are installing is the same as the one installed on the other workstations.
  • In addition, make sure all workstations are running either with Workgroup Manager or without Workgroup Manager. To find out whether Workgroup Manager is installed or not, open the Services application and check the menus: if you can see the Workgroup Manager menu, Workgroup Manager is installed.
  • Installing additional workstations does not affect the data (projects, ...) in the central file storage folder.
  • If you add new users to a new Allplan workstation, do not forget to add them to the Workgroup Manager, too.
  • Version 2014 and earlier: if one of the computers also serves as the Allplan server, you cannot use the approach described above to find out the path to the central file storage folder.
    In this case, you will see the path to a local folder instead of the central file storage folder.
    Use a different computer to find out the path to the central file storage folder.
Download PDF  FAQ_EN_Installing_Allplan_on_a_network_later.pdf ...
Version:  Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 17.12.2015
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How can I move NemSLock Server to a new server?



Answer:

Reinstalling NemSLock Server

  • Select one of the temporary license files for NemSLock server (for example, 1234567a_001_psd.nslsrv). These licenses are valid for 30 days. However, each license includes only one seat of each configuration purchased. The full number of seats purchased will be available to you as soon as you have installed the registered licenses (see below). If you purchased a configuration for one seat only, you will, of course, receive only one temporary license.
  • When you opt for the “Custom” setup type, you can choose between the following program features:
    Console
    You can use this program to administer NemSLock Server. The console can be installed on several workstations. This way, you can administer the server from a number of different locations. However, you can only connect one console to the server at any one time.
    Server
    The actual license server.
    Logviewer
    This tool analyzes the log files of NemSLock Server.
    User List Generator
    You can use this tool to create the users for NemSLock Server from a text file or based on a server.
    By default, Setup installs all these features.
  • If your license includes configurations for several seats, you need to install the additional temporary license files for NemSLock server after the installation (see below).


Transferring the user administration from the old server (if users are available)

  • You can find the user administration in the program folder of the license server. Copy the "users.mcf" file to the program folder of the new license server.
  • Stop the license server service on the new server before you copy the file. To do this, start the "stopService.bat" program, which is also in the program folder of the license server.
  • After copying, start the license server service again. To do this, use the "startService.bat" program.


Returning the registered licenses

  • Open NemSLock 2006 Server Console on the old server by clicking the icon on the desktop or Start -> (All) Programs -> NemSLock 2006 Server -> NemSLock 2006 Server Console.
  • Click "Stop server".
  • Click "Modules".
  • Click "Transfer license permanently".
  • Confirm the following dialog boxes. Click “Browse”.Windows Explorer starts and opens the folder with the hcws-format file. Now you can use all the options provided by Windows Explorer: for example, you can attach the file to an email, copy it to a computer with Internet access and so on.Send this file by email to register@nemetschek.de.
  • We will send you an email, confirming that we have received the licenses.
  • You always have to return all licenses.
  • After you have done this, they are only valid for two more days.


Registering the license(s) on the new server

  • Open NemSLock 2006 Server Console on the new license server.
  • Click "Modules" on the left.
  • Select the seat you want to register. If your license contains configurations for several seats, read the notes further down.
  • Click "Registration request (register.txt)".
  • Click "Edit".
  • Fill out all fields marked with an asterisk (*). Make sure you enter your email address correctly, because the registered license file will be sent to this address (and not to the address of the person who sent the registration request!). Click OK to confirm.
  • Click "Create registration request".Windows Explorer starts and opens the folder with the "register.txt" file. Now you can use all the options provided by Windows Explorer: for example, you can attach the file to an email, copy it to a computer with Internet access and so on.Send the registration request by email to register@nemetschek.de.


If your license includes configurations for several seats, you must send a separate registration request for each seat. You will then receive a registered license file for each seat. You must install each file.

How to install licenses

  • Open NemSLock 2006 Server Console.
  • Click "Stop server" on the left.
  • Click "Modules" on the left.
  • Click ”Browse” to navigate to the registered license file.
  • Click "Install license file".
  • After this, you can start the server again by clicking "Start server".


Configuring the clients

  • Now you need to change each client to the new license server.
  • Click Start -> (All) Programs -> Nemetschek -> Nemetschek SoftLock 2006 -> License Manager.
  • If the license server window is hidden, click "Configure NemSLock Server"at the bottom. It is a good idea to lock this window. All you need to do is click the drawing pin icon.
  • Enter the computer name or IP address of the license server in the empty box. Then click the "Update” icon to the right.
  • Now the user can select one of the seats provided. Click "Close" to complete the configuration. Now you can start Allplan.
  • After having successfully connected to the license server, clear the check boxes for the trial licenses in the area at the top.


Notes:

  • If a user selects several configurations for a seat and starts Allplan, the license server will provide the required licenses; in other words, starting Allplan once might require two licenses. Consequently, fewer licenses are available to other users.
  • 2014-1 and later: If the latest version of License Manager is installed (file version 1. 0. 26. 153 or later, see License Manager- Options- System), you can also select several licenses. If one of the selected licenses is currently being used by someone else, the program will automatically select the next available license.
  • Clients communicate with the server by TCP/IP via port 10977. So you need to configure the firewall accordingly.
  • The license server and the licenses are downward compatible; they can be used in conjunction with older Allplan versions.
Download PDF  FAQ_EN_Moving_NemSLock_Server_to_a_new_server.pdf ...
Version:  Allplan  | Last modified: 07.07.2017
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How can I access the FTP server of technical support?



Answer:

You can download data from and upload data to the FTP server.

To access our FTP server, you require a current Windows operating system. Do the following:

Please enter the following address in Windows Explorer (do not use Internet Explorer!):

ftp://nemhotline:ha37jvg8f@ftp.nemetschek.de


1. Downloading data:
You can find our data in the /Download folder.
Right-click the folder(s) or file(s) you want to download and select "Save Target As ...".
Specify where you want to copy the data by selecting a folder on your computer.

If customers agree, we can provide customer-specific data in the /Customerfolder.
For this, you will get separate instructions.


2. Uploading customer data:
If we agree, customers can upload data to the /Upload folder.



Notes:

  • You can upload only files. You cannot upload folders to the server. If you want to upload an entire project, please save this project to a ZIP file first.
  • You can also use Internet browsers to access the FTP server. However, there are some restrictions. Use an FTP client program (for example, FileZilla)to avoid errors. This makes it easier for you to upload and download data. See the following information.
  • Login details for FTP program:
    Address:
    ftp.nemetschek.de
    Login:
    nemhotline
    Password:
    ha37jvg8f
Download PDF  FAQ_EN_Data_on_FTP_server_.pdf
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 01.12.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

Why is it not possible to clear the check box for 'Find license server automatically' and why can't I enter an additional server name? These functions are grayed out.


Answer:

This problem is caused by Windows access rights. Only administrators can change these options.

Installing Allplan:
If this problem occurs during Setup and you cannot select a license, start by installing Allplan as a viewer.

Granting permissions later:
Assign full control to the users.
Local permissions prevent them from accessing the following file: Lic3LM.ini

Check whether the users have full control of the following folder:
Click folder with the right mouse button -> Properties -> Security -> Edit -> select the user - > grant full control

C:\ProgramData\Nemetschek(hidden file)

Open the 'License settings' dialog box: Services application -> Utilities -> License settingsYou should now be able to clear the check box and enter additional server names.

Download PDF  FAQ_EN_Finding_license_server_automatically_or_enter...
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017  | Last modified: 25.11.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

Whenever I try to create a project, the New Project, Open Projectdialog box does not open.
If I try to open ProjectPilot, the following message appears:Unable to create ProjectPilot control.What can I do?



Answer:

Some important entries are not defined in the Windows Registry.

Close Allplan and do the following:

Services application -> Service -> Windows Explorer -> CAD program folder -> PRG

Find the NemProjectPilot10.exefile and start it as the administrator. To do this, right-click this file -> Run as administrator.
Start Allplan and open ProjectPilot by clicking File -> ProjectPilot. Then create a new project.
After this, open New Project, Open Project. This should work without problems.



Note:

You require administrator privileges to write to the registry.

Download PDF  FAQ_EN_Projects_cannot_be_created_and_ProjectPilot_d...
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017  | Last modified: 25.11.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

During installation I get an error message saying that SetupSchedTaks.exe does not work anymore.

When I try to start Allplan or the Services application, the following message appears:
The program cannot start; api-ms-win-crt-runtime-l1-1-0.dll is missing.



Answer:

This problem is caused by missing DLl files, which are required by Allplan. These DLL files usually come with the operating system. You will only see these messages if the operating system is not up-to-date. These messages are not caused by Allplan.
Instead, this problem is caused by the KB2999226 or KB2918614 (Universal CRT) Windows updates, which contain parts of Visual C++ Redistributable for Visual Studio 2015. Sometimes you cannot install these updates or they are defective.

If you have not yet installed these updates, install them now. In addition, install all available updates.

If you have already installed these two updates, try to install them again.
If the operating system is configured to automatically install Windows updates, some clients report errors during installation of the KB2918614 or KB29992226 package. These errors are caused by Windows, which blocks installation of files of the Visual Redistributable 2015 package. In this case, you must uninstall or delete the updates. After this, try to install the updates again.


If you cannot install the updates, do the following:
1. Deactivate automatic updates
2. Start -> Control Panel -> Windows Update -> change the settings -> never check for updates
3. Restart the computer
4. Download and install missing updates
5. Activate automatic Windows updates again


If you still cannot install the updates, run Windows diagnostics to check your system for update problems.

You can also install the updates manually. Use the following links:

KB2918614:
https://www.microsoft.com/de-DE/download/details.aspx?id=43759

KB2999226:
https://www.microsoft.com/de-de/download/details.aspx?id=49093


Try this if you still cannot install the updates:
https://www.smartftp.com/support/kb/the-program-cant-start-because-api-ms-win-crt-runtime-l1-1-0dll-is-missing-f2702.html



Note:

Regarding this error message, we cannot fix anything on the part of Allplan. These DLL files, which are required by Allplan, are an integral part of the Windows operating system.

Download PDF  FAQ_EN_Missing_api-ms-win-crt-runtime-l1-1-0dll_prev...