Search Result

1 - 7 (7)
  • 1
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 01.10.2020
 

Question:

A new computer is to replace the existing one.
How can I transfer the existing data and settings of the existing Allplan installation to the new computer?



Solution:

Please note that this solution only works with stand-alone versions.
Install the same version of Allplan on the new computer and transfer the data as follows:

1st - transferring the data:
Transfer the following folders from the old computer to the new one:
Project folder (PRJ)
Office standard folder (STD) and
User folder (USR)

You can determine the path to these folders on both the new computer and the old computer as follows:
Services application->Service->Hotline Tools->Showcfg: shows system variables ->OK
You can find the paths to the folders after PRJ, STD and USR.

2nd - transferring the toolbar configuration:
Export the configurations from the old computer by clicking View -> Toolbars -> Customize... -> Export...
You can then import the configurations to the new computer by clicking View -> Toolbars -> Customize... -> Import...

Download PDF  FAQ_EN_Installation_on_a_new_computer_with_data_tran...
Version:  Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011  | Last modified: 15.11.2017
 

Question:

How can I update cross-section catalogs or install country-specific cross-section catalogs in Allplan 2011 and later?



Answer:

To install and save cross-section catalogs in Allplan 2011 and later, select Tools -> Defaults -> Cross-Section Catalogs. A dialog box opens. You can find a folder symbol and a disk symbol at bottom left.

To install cross-section catalogs, use the folder symbol. Another dialog opens, where you can select the cross-section catalog file you want to install. Select the file to be installed and click "Open" to confirm. This installs the corresponding cross-section catalog, which you can now use in Allplan.
To install country-specific cross-section catalogs, select the "Ing" folder, which was created when you installed Allplan. You can find it in the Allplan installation path (e.g., c:\Nemetschek\Allplan 201x\New\Ing - more information on the Allplan installation path is provided below in the "Notes" section).
This folder includes the country-specify cross-section catalog files.

To save a custom cross-section catalog, use the disk symbol. Another dialog opens, where you can select any folder to save the cross-section catalogs currently used in Allplan.



Note:

To update cross-section catalogs, you may need administrator privileges. If necessary, log on as an administrator before you start the update.

To use the cross-section catalogs for a specific project only, set the path settings for the cross-section catalogs of this project to project before you install the cross-section catalogs. In Allplan, open the "File" menu and select "Open Project..." Click the corresponding project with the right mouse button. Select "Properties". A dialog box opens. In the "Path settings" area, set the "Bar and mesh cross-section catalogs" to "Project".

To determine the path where Allplan is installed, use the Services application and select Service -> Hotline Tools-> showcfg. The Services application window shows the path of the Allplan installation folder.

The following abbreviations are used for the country-specific cross-section catalogs in the file names (axyzqusr.txt):
aut Austria
bel Belgium
bra Brazil
bul Bulgaria
deu Germany
eng England
fra France
hol Holland
hrv Croatia
ita Italy
kor Korea
pol Poland
rum Romania
rus Russia
slk Slovakia
svn Slovenia
swi Switzerland
tch Czech Republic
ung Hungary
usa USA

Download PDF  FAQ_EN_Updating_cross-section_catalogs_(Allplan_2011...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018  | Last modified: 12.11.2020
 

Question:

Why is Allplan running so slow?


Answer:

Check the following points:

1. Current version
Make sure you work with the current Allplan version.

  • Do the following or ask your system administrator to do this:
    Open Allplan and click the ‘?’ icon in the upper right-hand corner. Click ‘Update Allplan’.
    Select 'Find now'. If Allplan finds updates or hotfixes, download the installation packages.
  • Deactivate the virus scanner while your are installing updates or hotfixes. This might require administrator privileges. Contact your system administrator if you have problems.
  • Right-click the Allplan icon on the desktop. A shortcut menu opens.
    Select ‘Run as administrator’ and click ‘Yes’ to confirm the following message.
    As a result, Windows security settings do not block the installation.



2. System requirements:
Check the hardware and software required for your Allplan computer.

2.a)Download and run the system test.
Check the notes.
https://www.allplan.com/de/system/systemvoraussetzungen/

2.b)Check the Allplan system requirements:
https://www.allplan.com/de/system/systemvoraussetzungen/

2.c)You can find information about graphics cards at
https://connect.allplan.com/de/support/grafikkarten.html

2.d)You can find server operating systems you can use for the central file storage of Allplan at
https://connect.allplan.com/en/faqid/20140924094923.html


3. Hotline tools:
Start the Services application, open the ‘Service’ menu and select ‘Hotline Tools’. To save your settings, select the following tools.

- savestd: Saves user defaults.
- savereg: Saves CAD registry settings.

Start the Services application, open the ‘Service’ menu and select the following ‘Hotline Tools’:

- cleanup: Initializes the display.
- cleanstd: Resets CAD defaults.
- cleanreg: Resets CAD registry settings.

Check whether this has solved the problems.
If this is not so, restore the settings you just saved. To do this, start the Services application, open the ‘Service’ menu and select the following ‘Hotline Tools’:
- reststd: Restores saved user defaults.
- restreg: Restores CAD registry settings.


4. Color scheme selected in Allplan:
Start Allplan, open the ‘View’ menu, point to ‘Toolbars’ and select ‘Customize User Interface’. Open the ‘Customize’ tab and set ‘Color scheme and icon design’ to ‘Windows’.


5. Check the availability of all projects that are not online (if you use Workgroup Manager):
Start Allplan, open the ‘File’ menu and select ‘New Project, Open Project’. Deactivate ‘Check availability of all offline projects’.


6. Virus scanner
Check whether an anti-virus program is running in the background of the computer or server.
If so, reduce protection to "programs only".

Scanning "all files" can take a long time, considerably slowing down your computer when you switch between projects or exit the program.
You can exclude the Allplan installation folders from real-time scanning.When you start the Services application, you can see a list of the folders to be excluded.
You can find more information at
https://connect.allplan.com/en/faqid/20091126145752.html
Changes in the settings of the virus scanner only come into effect when you re-start the computer.


7. Aero desktop effects
Deactivate the Aero desktop effects of Windows.
To do this, open the Control Panel, select ‘Ease of Access’ and go to the ‘Make things on the screen easier to see’ area.
Select the ‘Turn off all unnecessary animations (when possible)’ option.


8. Name resolution on the network
If Allplan takes several minutes to start, name resolution on the network may not work.
To check this, do the following:
Right-click the Windows Start Button, select ‘Run’, type in ‘cmd’, click OK, type in ‘Nslookup’ and press ENTER.
Go to the line following the > character, type in the name of the Allplan data server and press ENTER.
The reply starts with the name and address of the server providing name resolution.
You can find the name and address of the Allplan data server in the second group.
If problems occur, contact your network administrator and ask him or her to configure name resolution correctly.


9. Speed of Allplan projects
Check whether some Allplan projects are slower than other Allplan projects.
Start with the empty project and check whether it is slow too.
After this, select any other Allplan project.

If it is only the current project that is slow, the problem may be caused by the data of the current project.
In this case, the data of this project must be analyzed in detail.
Contact technical support.


10. Network: checking out Allplan using Workgroup Manager
If you use Allplan with Workgroup Manager, you can check whether the problems are caused by the network. To do this, check out the workstation with the project in question and use the project on the local Allplan workstation.
You can find detailed information on checking out an Allplan workstation using Workgroup Manager in the
Services application. Open the ‘Help’ and select ‘Workgroup Manager’.

After you have checked out the workstation, Allplan no longer accesses the central file storage of the server.
If this has solved the problems, they are caused by the network. In this case, the network must be checked in detail.
Contact your network administrator and ask him or her to do this.

If the project is still slow, the problem may be caused by the data of the current project.
In this case, the data of this project must be analyzed in detail.
Contact technical support.


11. Log files and system information files
If all the points above do not solve the problems, technical support requires more system information about the computer running Allplan.

  • So, we would be grateful if you could send us a support request (Allplan Hotinfo with Allplan logging).
    To create a support request, start the Services application, open the ‘Service’ menu and select ‘Create support request (Hotinfo)’.
    Several dialog boxes open. Select ‘Technical Support Allplan’ and ‘Enquiry with Allplan logging’. Enter all the data required. Finally, click ‘Finish’.
    Another dialog box opens, prompting you to start Allplan. Click the ‘Start Allplan’ button.
    Allplan starts, logging all processes.
    Try to reproduce the problem as exactly as possible.
    Exit Allplan as soon as possible, reducing the data in the log file to a minimum.
    Then click ‘Next’ to generate the support request with the log file.
    You can find more information about Hotinfo at
    https://connect.allplan.com/en/faqid/20140528094911.html
  • To analyze the Windows system environment, we would ask you to send us the logs created by Windows Event Viewer of your computer.
    To start Windows Event Viewer, right-click the Windows Start Button, select ‘Run’ and type in ‘eventvwr.msc’.
    You can also type in ‘Event Viewer’ in the search box of Windows. This displays the link file to the Windows event logs.
    Using Event Viewer, create *.evtx files for the application log and the system log in the ‘Windows Logs’ area and for the ‘Administrative Events’ log in the ‘Custom Views’ area.


Please send us the files.

Download PDF  FAQ_EN_Allplan_is_running_slow.pdf
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 01.10.2020
 

Question:

Internet connection exists on your computer and the settings used for the proxy for the URLs you have set also. You try to activate your license with your product key, but the activation could not be performed. You get the message ' server not found error'. How can the license be activated yet?

Reply:

License activation:

The following description is valid for single user license as also license server licenses.

Try to activate the licenses on the computer/server via the following website online.
This Web site must be launched directly on the computer on which the license should be enabled.


http://lc.codemeter.com/59885/depot/index.php

In the row "Ticket", enter your Product Key and click continue your license will be displayed, click on activate license now.

Note: (only for license server license)
A selection appears asking for the binding of licenses.
Select firm code 6000100 on the right hand side.
'I want my licenses on one computer (CmActLicense). Firm code: 6000100 CmContainer ALLPLAN CM6 (2000)'

Sometimes multiple rows for the same license will be displayed (E.g. license number and a -u behind it) please leave all licenses checked and click on Activate selected licenses now.

The transfer of the license starts now. When activation is finished your license on this page should now appear with status activated.

If the problems with license activation occurred during the installation of ALLPLAN, cancel to exit Setup and restart the installation of ALLPLAN again. Then select in the Setup license configuration use active license now and the installation can continue.

Then open the license setting over services -> utilities-> license settings.
Or license server via License Settings.

Click on the left side on license selection. Now the license is displayed under the computer name.

License return:

This Web site must be launched directly on the computer on which the license should be enabled.


http://lc.codemeter.com/59885/depot/index.php

In the row "Ticket", enter your Product Key and click continue your license will be displayed, click on re-host license now.

Sometimes multiple rows for the same license will be displayed (E.g. license number and a -u behind it) please leave all licenses checked and click on Re-host selected licenses now.

The transfer of the license starts now.

Notes:

  • Sometimes the license is not displayed under license activation, because it has been enabled via the website.
  • If you want to remove the licenses, you must do so via the website again.
Download PDF  FAQ_EN_License_activation_returning_is_still_not_pos...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 01.10.2020
 

Question:

Does Allplan create backup files (*.bak)?
How can I use these files?



Answer:

Allplan creates backup files when you do the following:

  1. Copy, Move Elements between Documents …
    Allplan creates a backup file of the destination drawing file or layout.
  2. Deleting drawing files and layoutsin the "Open on a project-specific basis" dialog box
    If you have selected "Create backup copies of drawing files", Allplan creates a backup file of the drawing file or layout.
  3. Importing data to drawing files
    If you have selected "Create backup copies of drawing files", Allplan creates a backup file of the drawing file.


Note on points 2 and 3:

To select the "Create backup copies of drawing files" option, click
Tools -> Options -> Desktop environment -> Save/load area (until V2009 Global Options -> Miscellaneous -> Autosave, Backup)->Create backup copies of drawing files.


Restoring:

If need be, you can restore the original drawing file or layout.
Make a note of the drawing file number or layout number and determine the corresponding project folder as follows:
Services application -> Service -> Hotline Tools -> wopro

Open this folder in Windows Explorer.

Rename the corresponding drawing file "tb000001.ndw" "tb000001.ndw.old" or the corresponding layout "pb000001.000" "pb000001.000.old.", for example.
Delete the bak extension from the corresponding bak file.

Example 1:

You have inadvertently copied the wrong elements to drawing file 4711.
1st step: exit the project in Allplan.
2nd step: delete file tb004711.ndw or rename it tb004711.ndw.old.
3rd step: find file tb004711.ndw.bak and rename it tb004711.ndw.

Example 2:

You have inadvertently copied the wrong elements to layout 815.
1st step: exit the project in Allplan.
2nd step: delete file pb000815.000 or rename it pb000815.000.old.
3rd step: find file pb000815.000.bak and rename it pb000815.000.



Note:

These backup files can considerably increase the volume of data to be backed up. So it is a good idea to delete the .bak files you no longer require before you start backing up data. To delete the .bak files, you can select the Services application and click Utilities -> Delete temporary files.

You can also find this information in the help for Allplan. Please refer to the topic "Using bak files".

Download PDF  FAQ_EN_Using_bak_files.pdf
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017  | Last modified: 16.10.2020
 

Question:

How can I install additional Allplan workstations on an existing network (with or without Workgroup Manager)?



Answer:

Before you install the additional workstations, find out the path to the central file storage folder on a computer where Allplan has already been installed. Open the Services application on this computer. The Services application window shows the path to the central file storage folder.

Enter this path when Setup prompts you to specify the central file storage folder.
Select "Minimum" for the Setup type.



Notes:

  • Make sure the version you are installing is the same as the one installed on the other workstations.
  • In addition, make sure all workstations are running either with Workgroup Manager or without Workgroup Manager. To find out whether Workgroup Manager is installed or not, open the Services application and check the menus: if you can see the Workgroup Manager menu, Workgroup Manager is installed.
  • Installing additional workstations does not affect the data (projects, ...) in the central file storage folder.
  • If you add new users to a new Allplan workstation, do not forget to add them to the Workgroup Manager, too.
  • Version 2014 and earlier: if one of the computers also serves as the Allplan server, you cannot use the approach described above to find out the path to the central file storage folder.
    In this case, you will see the path to a local folder instead of the central file storage folder.
    Use a different computer to find out the path to the central file storage folder.
Download PDF  FAQ_EN_Installing_Allplan_on_a_network_later.pdf ...
Version:  Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 17.12.2015
 

Question:

After I have installed Allplan, the program no longer accepts the parallel dongle connected to the computer. Allplan starts as a viewer.
What can I do?



Answer:

The dongle query changed with Allplan 2013. The dongles causing these problems are usually parallel dongles that are connected to a port (LPT3) that was added later.

Determine the I/O range of the LPT port:

Open the Control Panel and then the Device Manager.

  • Select "Ports -> ECP Printer Port" for a direct parallel port.
  • Select "Multifunction adapter" and the corresponding port for a parallel adapter (e.g., SUNIX).


Properties -> Resources

Note down the first value in the first line below resource settings.

For example:

Resource typeSetting
I/O range0378 – 037F
I/O range0778 – 077F



In this example, the value is 0378.

Open Allplan's license settings:
Services application -> Utilities -> License -> License Settings

Switch to:
License check tab -> Specify searching order ... (or environment variable...)

Enter theI/O value followed by a "p"in the "HL_SEARCH=..." box. For example,
0378p

Click "OK" and then "Apply".


Download PDF  FAQ_EN_Parallel_dongle_is_no_longer_accepted_after_i...