Question:

How can I fix Allplan program data?


Answer:

You can fix Allplan program data by renaming the program folders and installing an update.
Due to the new names, Allplan cannot find the resources during the update. Consequently, it creates new resources.

To fix Allplan program data, do the following:

You need the latest installation package for your version.
You can download this package from Allplan Connect (www.connect.allplan.com) or from our FTP server.

Accessing the FTP server:
Enter the following address in Windows Explorer (do not use Internet Explorer!):
ftp://nemhotline:ha37jvg8f@ftp.nemetschek.de

You can find the installation packages in the following path:
/download/Allplan/"version"/CD/
Copy the zip file to the local computer and unzip the file.

  • Open the Services application of the Allplan version you want to fix.
  • Select Service -> Windows Explorer -> CAD program folder.
  • Rename the "PRG" folder "PRG_OLD". If Windows Explorer tells you that a file is still in use, restart the computer and try again.
  • Start the *.exe file of the installation package you just unzipped.
  • Select "Update installation".
  • When Setup prompts you for the license, select "Current license file" or "Use active license".
  • Select "Minimum" for the Setup type.



Allplan gets new program resources during installation.
As soon as the installation is complete, you can test how Allplan behaves.


Note:

If you are not sure, give these instructions to your system administrator.
Keep in mind that you install the version of the installation package you downloaded. This means that you may have to reinstall any subsequent hotfixes.

Download PDF  FAQ_EN_Fixing_Allplan.pdf
Version:  Allplan 2020 / Allplan 2019 / Allplan 2017 / Allplan 2016 / Allplan 2015  | Last modified: 12.06.2020
1 user(s) found this FAQ helpful

Question:

What can I do if Allplan no longer starts after I have upgraded and the following messages appear?
Allplan
Stop

...

After this, Quality Reporter displays an error report.



Answer:

Exit Allplan on all workstations and do the following:
Open the Services application and make a note of the path to the 'central file storage folder', which is displayed in the Services application window.
In addition, check whether the workgroup manager line is followed by 'Yes' or 'No'.

Open the central file storage folder in Windows Explorer.

If the workgroup manager line is followed by
'Yes', open the NET subfolder.
'No', open the PRJ subfolder.

Find the 'project.dat' or 'project.Dat.xm' file in the NET or PRJ folder and rename it 'project-old.dat'.

After this, do the following:
Services application -> Service -> Hotline Tools -> reorg -> OK -> Restore project management file -> OK
The program creates a new, correct project management file and you can start Allplan again.



Note:

If you come across error messages while doing this, please email the following information to support@allplan.com:

  1. Describe exactly what you did before the error or crash occurred.
  2. The error message itself (as a screenshot).
  3. The log file (trace).
    https://connect.allplan.com/en/faqid/0001a27a.html
  4. A Hotinfo support request with question 01.
    https://connect.allplan.com/en/faqid/20130823123806.html
Download PDF  FAQ_EN_Allplan_does_not_start_after_upgrade_Stop_mes...
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 25.11.2019
3 user(s) found this FAQ helpful

Question:

How can I restore a lost building structure or layout structure?



Answer:

To restore a lost or corrupt building structure or layout structure, you can do the following:

  • Close Allplan.
  • Open Windows Explorer, go to the central file storage folder of Allplan and open the "Prj"folder. Open the corresponding project folder and the "BIM" subfolder.

    Note:
    If the "Same folder name as project name" option is not selected for the project, a number is used for the folder name in the "Prj"folder. In this case, open the Services applicationand select the woprohotline tool (Services application -> Service -> Hotline Tools -> wopro). Select the corresponding project by double-clicking its name. An information dialog box shows the folder and file name of the project.
  • You can find an XML file for each structure in the BIM subfolder.


Building structure:
Allplan_BIM_BuildingStructure.xml

Objects derived from building structure:
Allplan_BIM_Views.xml

Plane model:
Allplan_BIM_LevMo_"name of model".xml

Layout structure:
Allplan_BIM_LayoutStructure.xml

  • To restore the building structure from a backup, rename the existing file "Allplan_BIM_BuildingStructure.xml" "Allplan_BIM_BuildingStructure.xml.old", for example.
  • Switch to the "Backup"folder, which you can also find in the"BIM"folder.
  • Select the most recent file that had been created beforethe building structure was deleted, for example, "Allplan_BIM_BuildingStructure.xml.27.5.2008--10-32-21.bak". The characters in bold indicate the date and time of the backup. Copy this file to the "BIM"folder.
  • Rename this file by deleting the characters after ".xml". Now the file name is "Allplan_BIM_BuildingStructure.xml".
  • Restart Allplan. The last version of the building structure is displayed in the "Open on a project-specific basis"dialog box again.




Note:

Using Allplan 2009-2 and later, you can restore the layout structure from a *.bak file straight from the "Open on a project-specific basis: layouts"dialog box.

  • Right-click the topmost structural level in the layout structure (project name) and select Load layout structure favoriteon the shortcut menu.
  • Open the last version of the Allplan_BIM_LayoutStructure.xml file in the backup folder mentioned above.


If the *.bak files are not displayed, please follow the steps described above.

Download PDF  FAQ_EN_Restoring_building_structure_layout_structure...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 01.10.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

Does Allplan create backup files (*.bak)?
How can I use these files?



Answer:

Allplan creates backup files when you do the following:

  1. Copy, Move Elements between Documents …
    Allplan creates a backup file of the destination drawing file or layout.
  2. Deleting drawing files and layoutsin the "Open on a project-specific basis" dialog box
    If you have selected "Create backup copies of drawing files", Allplan creates a backup file of the drawing file or layout.
  3. Importing data to drawing files
    If you have selected "Create backup copies of drawing files", Allplan creates a backup file of the drawing file.


Note on points 2 and 3:

To select the "Create backup copies of drawing files" option, click
Tools -> Options -> Desktop environment -> Save/load area (until V2009 Global Options -> Miscellaneous -> Autosave, Backup)->Create backup copies of drawing files.


Restoring:

If need be, you can restore the original drawing file or layout.
Make a note of the drawing file number or layout number and determine the corresponding project folder as follows:
Services application -> Service -> Hotline Tools -> wopro

Open this folder in Windows Explorer.

Rename the corresponding drawing file "tb000001.ndw" "tb000001.ndw.old" or the corresponding layout "pb000001.000" "pb000001.000.old.", for example.
Delete the bak extension from the corresponding bak file.

Example 1:

You have inadvertently copied the wrong elements to drawing file 4711.
1st step: exit the project in Allplan.
2nd step: delete file tb004711.ndw or rename it tb004711.ndw.old.
3rd step: find file tb004711.ndw.bak and rename it tb004711.ndw.

Example 2:

You have inadvertently copied the wrong elements to layout 815.
1st step: exit the project in Allplan.
2nd step: delete file pb000815.000 or rename it pb000815.000.old.
3rd step: find file pb000815.000.bak and rename it pb000815.000.



Note:

These backup files can considerably increase the volume of data to be backed up. So it is a good idea to delete the .bak files you no longer require before you start backing up data. To delete the .bak files, you can select the Services application and click Utilities -> Delete temporary files.

You can also find this information in the help for Allplan. Please refer to the topic "Using bak files".

Download PDF  FAQ_EN_Using_bak_files.pdf
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 12.11.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

Why does ProjectPilot open with the following error message:
"Unable to create ProjectPilot control. Is the registry correct?"



Answer:

The reason for this is usually an "external path" that no longer exists. When you start ProjectPilot,
the program tries to access the "external path", which is stored in the Windows Registry.
If this path no longer exists, you will see the above error message.

To correct this error, please do the following:

  • Services application
  • Service menu
  • Windows Explorer - CAD program folder
  • The path to the "User folder" is displayed in the window of the Services application. Open it in Windows Explorer.
  • Find the "extern.cfg"file in this user folder and delete this file.


Now try to start ProjectPilotagain. If the problem still occurs, please do the following:

Start the services application -> Service -> Windows Explorer -> CAD program folder.
Open the "PRG" folder.
Find the following file: "NemProjectPilot10.exe"
Right-click this file -> select "Run as administrator" on the shortcut menu.
ProjectPilot should now start.

Try to start ProjectPilotstraight from Allplan. If the problem is still not solved, please do the following:

  • Services application
  • Service menu
  • Windows Explorer - CAD program folder
  • The Allplan program folder opens.
  • Rename the "PRG" subfolder "PRG_OLD".
  • Start installing the program from the current Allplan DVD.
  • Select "Update installation".
  • Select "Current license file".
  • Set the setup type to "Minimum".


After installation try to start ProjectPilotagain.

Download PDF  FAQ_EN_Error_message_when_ProjectPilot_starts_Unable...
Version:  Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011 / Allplan 2009 / Allplan 2008  | Last modified: 02.09.2016
4 user(s) found this FAQ helpful

Question:

How can I transfer the NemSLock license permanently to a new computer?



Answer:

Proceed as follows:

  • Install the program on the new computer. Use the temporary license (xxx_xxx_psd.nslock) you received when you purchased the program. If you do not have a temporary license of the current version, contact your support team to request such a license.
    You can then work with the program for 30 days – plenty of time to configure your new computer, transfer the office standard and projects and so on (you can find instructions in the FAQ database).
    At the same time you can work with the program on your old computer without any restrictions.
  • When you have transferred everything you need, return the license to us. To do this, use the old computer and click
    Start -> (All) Programs -> Nemetschek -> Nemetschek SoftLock 2006 -> License Manager
    (Services application -> Utilities -> License -> License Manager (NemSLock)).

    Click "Relocate licenses -> Transfer licenses permanently to a computer". This creates the COMPUTER_NAME.hrdwchg file. Send this file by email to register@nemetschek.de.


Tip: Click 'Browse' in the 'Send hardware change file (*.hrdwchg)' dialog box. The program creates and saves the COMPUTERNAME.hrdwchgfile. Then Windows Explorerstarts and the folder with the hardware change file opens. You can now use all the options provided by Windows Explorer: for example, you can attach the file to an email, copy it to a computer having Internet access and so on. Email this file to register@nemetschek.de.

Note:
After you have created this file, the Allplan license of your old computer will still be valid for two more days.
As soon as we have removed the registration, we will send you a confirmation by email.

  • Create a registration request (register.txt) on the new computer and send this file by email to register@nemetschek.de.

    To generate a registration request, do the following:
    Open the License Manager (Service application -> Utilities- > License -> License Manager). Select the license entry for your seat and click "Request license". Please follow the instructions displayed on screen. Complete the form. Do not forget to enter your email address.

    You will promptly receive the license for the new computer (provided you have returned the license to us as described above).
    Installing this license file completes the license transfer to the new computer.



Note:

The COMPUTER_NAME.hrdwchg file is stored in the following folder:

Allplan 2012 and earlier:

  • Windows 64-bit:

C:\Program Files (x86)\Common Files\Nemetschek\NemSLock2006\License

  • Windows 32-bit:
    C:\Program Files\Common Files\Nemetschek\NemSLock2006\License


Allplan 2013 and later:

  • C:\ProgramData\Nemetschek\NemSLock\AllplanLicense
  • or C:\ProgramData\Nemetschek\NemSLock\HardwareTausch
Download PDF  FAQ_EN_Transferring_NemSLock_license_permanently_to_...
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012  | Last modified: 30.01.2020
1 user(s) found this FAQ helpful

Task:

You have installed Allplan on several local workstations. Now you want to change the installation so that you can access a common network drive.



Note:

Before you switch to a network installation, it is essential that you back up all the data of all the workstations.
We strongly recommend that you take advantage of the expertise of Nemetschek’s technical support staff. We are happy to help you!



Solution:

The following description shows how to change several workstations where Allplan is installed locally and the project data is also stored locally on each computer to workstations with a common network drive without Workgroup Manager.

1st - getting ready
Choose one of the workstations where you will install all the projects and the office standard (hereinafter referred to as the main workstation).
First, move all the projects to the main workstation.

1.a: copying resources into projects
To make sure that the projects in your office have a uniform appearance, change the path settings for the projects' resources to 'Project'.
Make the following setting for each project:
Allplan -> File menu -> ProjectPilot - Admin -> select the individual projects one after the other -> right mouse button -> Properties -> Settings tab
Set the path settings for 'Pen and line definitions', 'Fonts', 'Patterns, hatching styles, area styles', 'Bar and mesh cross-section catalogs', 'Layer structures, line styles, drawing types' and 'Attributes proposed' from 'Office' to 'Project', if necessary.
The corresponding elements are copied from the office standard directly to the project. This ensures that the project settings stay the same even when you copy the project to the new server with the new office standard.

1.b: same folder name as project name
Open the 'General' tab and select the 'Same folder name as project name' setting if you want to proceed as described in 2b.

1.c: pen color ("Color stands for pen")
The pen color for the "Color stands for pen" setting is a user-specific setting that is not saved in the project but in the user folder (...\Usr).

2.a: backing up projects of the individual workstations and importing them to the main workstation (recommended method):
Back up the individual projects. To do this, open the Services application and select Data Backup -> Create -> Entire folders -> Projects.
You can back up several projects in a single operation.
Before you start, specify the backup folder on the network or on the local hard disk: Services application -> Configuration -> Backup path ->Browse for Folder.

The next step is to import the saved projects to the main workstation.To do this, open theServices application -> Data Backup -> Import -> Projects Before you import the individual projects, you can create new Allplan projects at the main computer. As an alternative, you can also create a new project during the import.

2.b: backing up projects of the individual workstations and importing them to the main workstation (special approach):
This approach should only be used with good reason for exceptional cases as it requires in-depth knowledge of Windows.
With this method, Windows Explorer is used to import the projects to the main workstation.
If some project names exist twice, you need to rename these projects before you back them up.

You can then rename the existing 'project.dat' file in the Prj folder of the main workstation.
Next, select the Services application -> Service -> Hotline Tools -> reorg -> Restore project management file.
The system creates a new project administration file (project.dat), which should list all projects with names.

Now the main workstation contains the latest version of all the projects of the office.

3rd - merging project defaults
Open ProjectPilot at the individual workstations and copy the elements you want to transfer (symbols, smart symbols, lists, schedules, and so on) to the external path. Of course, you can set the external path to a common network folder that can be accessed by all workstations.
Next, open ProjectPilot at the main workstation and copy the contents of the external path to the office standard.

4th - data backup

  • Back up the projects, office standard and user settings at the main workstation:
    You can also copy the ..\prj (projects), ..\std (office standard) and ..\usr (user folder) paths to a backup folder (Nemsic, for example) on the hard disk.
  • In addition, you need to back up the ..\usr\local folder at every stand-alone computer.
  • Export the user interface setting of each user to a file: Allplan -> Tools - > Customize .... -> Export...


5th - uninstalling
Remove Allplan from all workstations.

6th - reinstalling
Before you install the same version again, create and share a folder (Nemdata, for example) on the future data server. Create a subfolder - Allplan - in this folder.

The next step is to reinstall the same version on all the workstations.

Specify the following installation paths:
Program folder:
local (C:\Programs\Nemetschek\Allplan, for example)
Central file storage folder:
Browse -> Network...
Find the sharedNemdata folder and select the Allplan folder.

After this, start installing.

7th - testing the start and restoring the backup
After the installation (check whether Allplan starts), copy the ..\prj and ..\std folders you backed up from the main workstation to the new ...\Nemdata\Allplan server folder.

Next, use Windows Explorer to copy the contents of the former user folder (…\usr\local) of the stand-alone workstation to the new user folder of the computer you just installed.

8th - updating the project administration file
Go to the project.datfile in the ...\Nemdata\Allplan\Prjfolder and rename itproject.alt.After this, do the following:
Services application -> Service -> Hotline Tools -> reorg -> Restore project management file.

9th - summary
Now all the workstations access a common network drive with the same project pool and office standard.
With this type of installation, only one user can access a project at any one time. If several users are to work on a project at the same time, you need to install Workgroup Manager.

Download PDF  FAQ_EN_Switching_from_single_installation_to_network...
Version:  Allplan 2014 / Allplan 2013 / Allplan 2012  | Last modified: 04.01.2018
5 user(s) found this FAQ helpful

Question:

After I have updated the driver of a graphics card from the Nvidia Quadro or GeForce series, I cannot start Allplan anymore.
I can see numerous error messages. What can I do?



Answer:

Allplan no longer starts after you have installed a current driver of the Nvidia GeForce or Nvidia Quadro WHQL series.


You can solve the problem as follows:

For customers running Allplan 2014:
Install at least version 2014-1-3. This version works with the drivers mentioned above.

For customers running Allplan 2013 or an earlier version:
Start the Services application.
Select Service -> Windows Explorer -> General program data.
(Allplan 2012: Services application -> Service -> Windows Explorer (program folder))
Open the ETC folder and then the "Shaders" folder, for example, C:\ProgramData\Nemetschek\Allplan\2013\Etc\Shaders.
Find the "Postprocess.frag" file and rename it "Postprocess.OLD".
Copy the "Postprocess.frag" file, which you can find attached to this FAQ, into the "Shaders" folder.

A note on Allplan 2014-1-3:
Download this version from Allplan Connect or from the FTP server.

Allplan Connect:
https://connect.allplan.com/de/support/downloads.html

FTP server:
ftp://nemhotline:ha37jvg8f@ftp.nemetschek.de/download/Allplan/2014/CD/
Copy this link and paste it into the address bar of Windows Explorer. Then press ENTER.
This opens the folder on our FTP server.
Select the appropriate file (for example, 'DoWn-allplan2014-1-3_x64-cad.zip' for 64-bit systems) and select Edit -> Copy (Ctrl+C). (If you run the Windows 32-bit system, download the other file.)
Switch to a folder on your computer and select Edit -> Paste (Ctrl+V).
After having downloaded the file, you can decompress it and start installing it by double-clicking the exe file.
To download large files, you can also use a download client, such as Filezilla (http://filezilla-project.org/).

Download PDF  FAQ_EN_Allplan_does_not_start_after_update_of_graphi... Download Postprocess.frag
Version:  Allplan  | Last modified: 07.07.2017
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How can I access the FTP server of technical support?



Answer:

You can download data from and upload data to the FTP server.

To access our FTP server, you require a current Windows operating system. Do the following:

Please enter the following address in Windows Explorer (do not use Internet Explorer!):

ftp://nemhotline:ha37jvg8f@ftp.nemetschek.de


1. Downloading data:
You can find our data in the /Download folder.
Right-click the folder(s) or file(s) you want to download and select "Save Target As ...".
Specify where you want to copy the data by selecting a folder on your computer.

If customers agree, we can provide customer-specific data in the /Customerfolder.
For this, you will get separate instructions.


2. Uploading customer data:
If we agree, customers can upload data to the /Upload folder.



Notes:

  • You can upload only files. You cannot upload folders to the server. If you want to upload an entire project, please save this project to a ZIP file first.
  • You can also use Internet browsers to access the FTP server. However, there are some restrictions. Use an FTP client program (for example, FileZilla)to avoid errors. This makes it easier for you to upload and download data. See the following information.
  • Login details for FTP program:
    Address:
    ftp.nemetschek.de
    Login:
    nemhotline
    Password:
    ha37jvg8f
Download PDF  FAQ_EN_Data_on_FTP_server_.pdf
Version:  Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011  | Last modified: 08.05.2019
2 user(s) found this FAQ helpful

Question:

I have installed Allplan using the temporary Softlock license ("customer#_seat_psd.nslock") and "Trial" is displayed for its status in the License Manager.
How can I register this license?



Answer:

You use License Manager to create a registration request and send it by email to register@nemetschek.de.
In response, you get a final license file. Installing this license removes the lime limit.
Below is a description of the necessary steps.



Notes:

  • Using the temporary license, you can start Allplan as a trial version. You can work with Allplan without any restrictions for 30 days.
    After expiration of this period, Allplan starts as a viewer only. However, you can still request and install the final license.
  • When running Windows Vista, start Nemetschek License Manager as the administrator:
    Start -> (All) Programs -> Nemetschek -> Nemetschek SoftLock 2006 -> License Manager
    Click "License Manager" with the right mouse button and choose "Run as administrator" on the shortcut menu.




How to proceed:

1. Request a license registered for your computer

  1. On the Windows taskbar, click Start - (All) Programs - Nemetschek - Nemetschek Softlock 2006 - License Manager(or Services application -> Utilities -> License -> License Manager (NemSLock)).

    When running Windows Vista, start License Manager as the system administrator: click Start - (All) Programs - Nemetschek - Nemetschek Softlock 2006 - License Manager.
    Click License Managerwith the right mouse button. On the shortcut menu, click Run as administrator.
  2. Select the seat you want to register so that it is highlighted in blue.

    Note:You can only register seats you have purchased. If you can see only seats with numbers between 90 and 99 (= trial licenses for temporary use), you first need to install the personal license for temporary use.
  3. Click License requestat top left.

    The License Request Wizardstarts. The Welcome to the license request wizarddialog box provides information on the steps that follow.
  4. Click Next >.
    The Customer detailsdialog box opens.

    Note: Editing customer details requires administrator privileges. If you do not have these privileges, you will see a corresponding message. Cancel NemSLock License Manager and start again by selecting the Run as administrator option on the shortcut menu.
  5. Enter the necessary details:

    - If the Client IDhas eight zeros (00000000) and the CD Keyhas eight capital F's (FFFFFFFF), you selected the Trial license for temporary useoption when you installed Allplan.
    In this case, install the personal license for temporary use before you create the registration request.

    - If Client IDand CD Keydo not match the numbers printed on your delivery note (for example, typing errors, small letters and capital letters mixed up), you can enter Client ID and CD Key manually.

    - Fill out all the fields.

    Make sure you enter your email address correctly, because registered licenses and replies to status queries of license will be sent to the address you specify here.

    Note:Check the entries for Client ID(customer number) and CD Key , making sure these numbers are the same as those printed on the delivery note you received from Allplan. The CD Keyusually consists of the numbers 0 to 9 and the capital letters A to F.

    Tip: You can also find these numbers in the personal license file for temporary use (*_psd.nslock). Open the license file in an editor and scroll down to the end of the file. You can then copy the license codes displayed after CUSTOMERand CDKEYto the Clipboard and paste them into the appropriate boxes.
  6. Click Next >.
  7. Select the Program, Versionand Seatand click Next >.

    Note: If the Client IDis invalid (for example, when you use a trial license) you cannot confirm the dialog box by clicking OK. Instead, you will see a corresponding message.
  8. Specify how to send the registration file and click Next >.

    Start email program ...
    The program creates and saves the register.txt file before it opens your default email program. The program automatically attaches the registration file to the email and enters register (please no spam) @ (please no spam) nemetschek.defor the address.

    Save the registration file ...
    The program creates and saves the register.txt file before it opens the folder with the registration file in Windows Explorer. Now you can use all the options provided by Windows Explorer: for example, you can attach the file to an email, copy it to a computer with Internet access and so on.

    In addition, you can see the data that were written to the registration file.
  9. Click Finish.
  10. Click Close to exit NemSLock License Manager.


You will receive a reply by email within a few minutes. This email provides information on the registration process and usually includes the registered license file.

Note: The registered license file is generated by an automated system. Consequently, any additional comments in incoming emails are not read. If you have any questions or need more information, please contact Allplan directly.



2. Install the license file

Shortly after you sent the registration request to 'register@nemetschek.de' as described in step 1, the final license file will be sent to the email address you specified in the registration request.
Install this license file as follows:

  • Save the license file to any folder on the hard disk.
    If the license comes as a zip file, extract it.
  • Next, install the license file by double-clicking it ("customer#_seat.nslock").
    Confirm the dialog box.
  • As an alternative, you can also use License Manager to install the license file (Start -> (All) Programs -> Nemetschek -> Nemetschek SoftLock 2006 -> License Manager).
    Click "Install - Install license" at top left in Nemetschek SoftLock License Manager and select the license by clicking "Browse...".
    Click "Finish" to complete the installation process.


Note:

Do not use the same computer to register several license files for different seats. This would connect the seats. You cannot separate the seats again without the help of technical support.

Download PDF  FAQ_EN_Nemetschek_Softlock_-_first_steps.pdf
1 - 10 (16)
https://campus.allplan.com/ uses cookies  -  More information

Accept