Search Result

1 - 10 (14)
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011  | Last modified: 05.10.2020
 

Question:

I just installed an upgrade. How can I convert all the projects at once?



Answer:

Back up all the projects beforehand!

Do the following:

  • Exit Allplan on all workstations.
  • Only when working with Workgroup Manager:
    Log in as the Allplan administrator (sysadm).
  • Start the Services application.
  • Only when working with Workgroup Manager:
    Make sure all the computers where projects are located are up and running.
    To check this, select:
    Services application -> Workgroup Manager -> Information -> Display Project List(the second column displays the computer where the project is located).
  • Go to the computer where you want to convert the data and set the drawing file size to the maximum value:
    Services application->Service ->Hotline Tools->docsize ->512 (or 1024, if available) ->OK
    Note:
    After data conversion, you can set the drawing file size back to the initial value.
  • Start converting the data (use the computer where you have changed the drawing file size):
    Services application ->Service ->Hotline Tools -> datwaprjs: convert data of all projects
    If you reply "Yes" at the following two prompts, the program will convert the data of all projects.



Notes:

The time it takes to convert the data depends on various factors:

  • Number of projects
  • Size of each project
  • Performance of the computer converting the data
  • Network performance


It is possible to start data conversion from several workstations at the same time.

Download PDF  FAQ_EN_Converting_all_Allplan_projects_in_a_single_o...
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014  | Last modified: 25.11.2019
 

Question:

How can I permanently change the path settings presented for selection in specific tools (save, import)?



Answer:

When you save, import and export elements or files, Allplan automatically proposes a specific folder where the data is saved or taken from.
You can specify which Allplan file type is saved in which folder. These folders are automatically presented in the "Save" dialog box of the relevant file type. However, you can change them at any time.

To set this proposed folder on an individual basis, do the following:
Select the Tools menu ->Options... -> Desktop environment(Allplan 2009 and earlier: Tools -> Options... -> Global Options-> "Settings"tab).

You can click thePAah setting sbutton to the right of Folders for savingto define defaults. You can choose Project, Private, Custom or Last for the path setting:

  • Project: the file type is saved in the current project (not available for NDW and NPL files).
  • Private: the file type is saved in the user's private project.
  • Custom: you can specify any folder for the file type. To select the folder, click the path displayed in the Folder column and enter a new path or click ... in the Browse column and select the path in a dialog box.
  • Last: the file type is saved in the path you selected last.
Download PDF  FAQ_EN_Default_path_settings.pdf
Version:  Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 16.12.2020
 

Question:

After I updated Windows (8 to 8.1; 8.1 to 10), Allplan only starts as a viewer. What can I do?


Answer:

Windows update corrupts Nemetschek Softlock License Manager.
To fix Allplan, do the following:

You need the latest installation package for your version.
You can download this package from our webdrive

https://webdrive.allplan.com/s/4LrjrymoxESzC6p

You can find the installation packages in the following path:
Allplan/"Version"/Installationspaket/

Copy the zip file to the local computer and unzip the file.
Start the installation and run an update use our temporary license file.

You can download the temporary license from Allplan Connect:
https://connect.allplan.com


After the installation, you can open License Manager again (Services application -> Utilities -> License -> License Manager). Next, install the temporary license (*_psd.nslock): "Install - Install license"
Note: the status of the temporary license is set to "Expired".

Next, create a new registration request.
To generate a registration request, do the following:

Open License Manager (Services application -> Utilities -> License -> License Manager). Select the license entry for your seat and click "Request license".
Follow the instructions displayed on screen. Complete the form. Do not forget to enter your email address.

Check that the Client ID and CD Key are correct.

Send the registration request to: register@nemetschek.de.

Download PDF  FAQ_EN_Fixing_NemSLock_after_Windows_update.pdf ...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 16.12.2020
 

Question:

What can I do if Allplan does not start?


Answer:


Work through the following steps:

Step 1 - run as administrator
Start Allplan with the ‘Run as administrator’ option.
To do this, right-click the Allplan icon and click ‘Run as administrator’.
If Allplan does not start, go to step 2.

Step 2 - cleanup
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanup -> OK
If Allplan does not start, go to step 3.

Step 3 - cleanstd
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanstd: reset CAD defaults -> OK -> OK -> Yes -> OK
If Allplan does not start, restore the settings:
Services application -> Service -> Hotline Tools -> laststd: restore the last settings -> OK -> OK -> Yes -> OK
Go to step 4.

Step 4 - cleanreg
Allplan is not running. Start the Services application and do the following:
Services application -> Service -> Hotline Tools -> cleanreg: reset CAD registry settings -> OK -> OK -> Yes -> OK
If Allplan does not start, restore the registry settings:
Services application -> Service -> Hotline Tools -> lastreg:restore most recent CAD registry settings -> OK -> OK -> Yes -> OK
Go to step 5.

Step 5 (Allplan 2016 and later)
Restart the Wibu service:
Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.

CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.

If Allplan does not start, go to step 6.

Step 6 (Allplan 2016 and later)
Go to the Wibu website and install CodeMeter User Runtime Version for Windows (64-bit version).
You can find the installation program at https://www.wibu.com/de/anwendersoftware.htmlor on the Nemetschek FTP server ftp://nemhotline:ha37jvg8f@ftp.nemetschek.deat download/General/Wibu/CodemeterRuntime.exe

Start the ‘CodeMeterRuntime.exe’ file.
To do this, right-click this file and select
‘Run as administrator’.
Confirm all messages displayed and the defaults by clicking ‘Next’.
CodeMeter Control Center will be installed afterwards.
If Allplan does not start, go to step 7.

Step 7 - contact Technical Support
Send the following information by email to support.de@allplan.com:

  1. An exact description of the last step before the error or crash occurred.
  2. The error message itself (as a screenshot). To find out how to take a screenshot, look at
    https://connect.allplan.com/en/faqid/0001cb36.html
  3. A support request (Hotinfo) with question 01. To find out how to create a support request, look at
    https://connect.allplan.com/en/faqid/20140528094911.html
  4. The 'Allplan.out' log file. To find out how to create a support request, look at
    https://connect.allplan.com/en/faqid/0001a27a.html
  5. Allplan 2016 and later -> a screenshot of the Wibu Control Center. To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.


We will contact you.

Download PDF  FAQ_EN_Allplan_does_not_start.pdf
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 30.09.2020
 

Question:

How can I make several projects available to users when Workgroup Manager is installed?



Answer:

You can make several projects available to a user or define a user as the project owner of several projects.

Do the following:

First, log in as the Allplan administrator.
If necessary, set up an Allplan user for the new Windows user: Services application -> Workgroup Manager -> Configuration -> Add a user
(Allplan 2014 and later:Services application -> Workgroup Manager ->Administer users)

Start Allplan and then ProjectPilot by clicking
File -> ProjectPilot

Open the Projects folder in the area on the left.
You can see all the projects in the Contents of "Projects" area on the right.

a. Making several projects available to users:
In the area on the right, select the projects to which you want to add users or from which you want to remove users (CTRL or SHIFT key or use a selection rectangle).

Click one of the selected projects with the mouse button. On the shortcut menu, click
Add / remove authorized users...
The Add / Remove Authorized Usersdialog box opens.

Select the users you want to add to or remove from the selected projects.
Note:
The user list displayed only helps you select users. It does not list all the authorized users currently assigned to projects.

Click Addor Remove.
This adds or removes the selected users to or from the selected projects. Whether users you have already added to a project are added again is irrelevant. The same applies if you remove users you have never added to a project.

b. Defining a project owner for several projects
In the area on the right, select the projects for which you want to define the owner (CTRL or SHIFT key).

Click one of the selected projects with the mouse button. On the shortcut menu, click
Change project owner...
The Define Owner dialog box opens.

Select the user you want to define as the owner of the selected projects.
Note: The user list displayed helps you select users. You can define only one user as the owner.

Click OK.

c. Defining a project owner for a project or making a project available to several users(also applies to earlier versions):
In ProjectPilot in the area on the right, click the relevant project with the right mouse button. On the shortcut menu, click Properties.
The Properties for <project name>dialog box opens. Switch to the Security tab and define the owner and the authorized users.



Note:

You can add or remove project users or define the project owner only if the projects in question are in the current Allplan format.

Download PDF  FAQ_EN_Making_several_projects_available_to_users.pd...
Version:  Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011 / Allplan 2009 / Allplan 2008  | Last modified: 02.09.2016
 

Question:

How can I transfer the NemSLock license permanently to a new computer?



Answer:

Proceed as follows:

  • Install the program on the new computer. Use the temporary license (xxx_xxx_psd.nslock) you received when you purchased the program. If you do not have a temporary license of the current version, contact your support team to request such a license.
    You can then work with the program for 30 days – plenty of time to configure your new computer, transfer the office standard and projects and so on (you can find instructions in the FAQ database).
    At the same time you can work with the program on your old computer without any restrictions.
  • When you have transferred everything you need, return the license to us. To do this, use the old computer and click
    Start -> (All) Programs -> Nemetschek -> Nemetschek SoftLock 2006 -> License Manager
    (Services application -> Utilities -> License -> License Manager (NemSLock)).

    Click "Relocate licenses -> Transfer licenses permanently to a computer". This creates the COMPUTER_NAME.hrdwchg file. Send this file by email to register@nemetschek.de.


Tip: Click &apos;Browse&apos; in the &apos;Send hardware change file (*.hrdwchg)&apos; dialog box. The program creates and saves the COMPUTERNAME.hrdwchgfile. Then Windows Explorerstarts and the folder with the hardware change file opens. You can now use all the options provided by Windows Explorer: for example, you can attach the file to an email, copy it to a computer having Internet access and so on. Email this file to register@nemetschek.de.

Note:
After you have created this file, the Allplan license of your old computer will still be valid for two more days.
As soon as we have removed the registration, we will send you a confirmation by email.

  • Create a registration request (register.txt) on the new computer and send this file by email to register@nemetschek.de.

    To generate a registration request, do the following:
    Open the License Manager (Service application -> Utilities- > License -> License Manager). Select the license entry for your seat and click "Request license". Please follow the instructions displayed on screen. Complete the form. Do not forget to enter your email address.

    You will promptly receive the license for the new computer (provided you have returned the license to us as described above).
    Installing this license file completes the license transfer to the new computer.



Note:

The COMPUTER_NAME.hrdwchg file is stored in the following folder:

Allplan 2012 and earlier:

  • Windows 64-bit:

C:\Program Files (x86)\Common Files\Nemetschek\NemSLock2006\License

  • Windows 32-bit:
    C:\Program Files\Common Files\Nemetschek\NemSLock2006\License


Allplan 2013 and later:

  • C:\ProgramData\Nemetschek\NemSLock\AllplanLicense
  • or C:\ProgramData\Nemetschek\NemSLock\HardwareTausch
Download PDF  FAQ_EN_Transferring_NemSLock_license_permanently_to_...
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012  | Last modified: 30.01.2020
 

Task:

You have installed Allplan on several local workstations. Now you want to change the installation so that you can access a common network drive.



Note:

Before you switch to a network installation, it is essential that you back up all the data of all the workstations.
We strongly recommend that you take advantage of the expertise of Nemetschek’s technical support staff. We are happy to help you!



Solution:

The following description shows how to change several workstations where Allplan is installed locally and the project data is also stored locally on each computer to workstations with a common network drive without Workgroup Manager.

1st - getting ready
Choose one of the workstations where you will install all the projects and the office standard (hereinafter referred to as the main workstation).
First, move all the projects to the main workstation.

1.a: copying resources into projects
To make sure that the projects in your office have a uniform appearance, change the path settings for the projects&apos; resources to &apos;Project&apos;.
Make the following setting for each project:
Allplan -> File menu -> ProjectPilot - Admin -> select the individual projects one after the other -> right mouse button -> Properties -> Settings tab
Set the path settings for &apos;Pen and line definitions&apos;, &apos;Fonts&apos;, &apos;Patterns, hatching styles, area styles&apos;, &apos;Bar and mesh cross-section catalogs&apos;, &apos;Layer structures, line styles, drawing types&apos; and &apos;Attributes proposed&apos; from &apos;Office&apos; to &apos;Project&apos;, if necessary.
The corresponding elements are copied from the office standard directly to the project. This ensures that the project settings stay the same even when you copy the project to the new server with the new office standard.

1.b: same folder name as project name
Open the &apos;General&apos; tab and select the &apos;Same folder name as project name&apos; setting if you want to proceed as described in 2b.

1.c: pen color ("Color stands for pen")
The pen color for the "Color stands for pen" setting is a user-specific setting that is not saved in the project but in the user folder (...\Usr).

2.a: backing up projects of the individual workstations and importing them to the main workstation (recommended method):
Back up the individual projects. To do this, open the Services application and select Data Backup -> Create -> Entire folders -> Projects.
You can back up several projects in a single operation.
Before you start, specify the backup folder on the network or on the local hard disk: Services application -> Configuration -> Backup path ->Browse for Folder.

The next step is to import the saved projects to the main workstation.To do this, open theServices application -> Data Backup -> Import -> Projects Before you import the individual projects, you can create new Allplan projects at the main computer. As an alternative, you can also create a new project during the import.

2.b: backing up projects of the individual workstations and importing them to the main workstation (special approach):
This approach should only be used with good reason for exceptional cases as it requires in-depth knowledge of Windows.
With this method, Windows Explorer is used to import the projects to the main workstation.
If some project names exist twice, you need to rename these projects before you back them up.

You can then rename the existing &apos;project.dat&apos; file in the Prj folder of the main workstation.
Next, select the Services application -> Service -> Hotline Tools -> reorg -> Restore project management file.
The system creates a new project administration file (project.dat), which should list all projects with names.

Now the main workstation contains the latest version of all the projects of the office.

3rd - merging project defaults
Open ProjectPilot at the individual workstations and copy the elements you want to transfer (symbols, smart symbols, lists, schedules, and so on) to the external path. Of course, you can set the external path to a common network folder that can be accessed by all workstations.
Next, open ProjectPilot at the main workstation and copy the contents of the external path to the office standard.

4th - data backup

  • Back up the projects, office standard and user settings at the main workstation:
    You can also copy the ..\prj (projects), ..\std (office standard) and ..\usr (user folder) paths to a backup folder (Nemsic, for example) on the hard disk.
  • In addition, you need to back up the ..\usr\local folder at every stand-alone computer.
  • Export the user interface setting of each user to a file: Allplan -> Tools - > Customize .... -> Export...


5th - uninstalling
Remove Allplan from all workstations.

6th - reinstalling
Before you install the same version again, create and share a folder (Nemdata, for example) on the future data server. Create a subfolder - Allplan - in this folder.

The next step is to reinstall the same version on all the workstations.

Specify the following installation paths:
Program folder:
local (C:\Programs\Nemetschek\Allplan, for example)
Central file storage folder:
Browse -> Network...
Find the sharedNemdata folder and select the Allplan folder.

After this, start installing.

7th - testing the start and restoring the backup
After the installation (check whether Allplan starts), copy the ..\prj and ..\std folders you backed up from the main workstation to the new ...\Nemdata\Allplan server folder.

Next, use Windows Explorer to copy the contents of the former user folder (…\usr\local) of the stand-alone workstation to the new user folder of the computer you just installed.

8th - updating the project administration file
Go to the project.datfile in the ...\Nemdata\Allplan\Prjfolder and rename itproject.alt.After this, do the following:
Services application -> Service -> Hotline Tools -> reorg -> Restore project management file.

9th - summary
Now all the workstations access a common network drive with the same project pool and office standard.
With this type of installation, only one user can access a project at any one time. If several users are to work on a project at the same time, you need to install Workgroup Manager.

Download PDF  FAQ_EN_Switching_from_single_installation_to_network...
Version:  Allplan  | Last modified: 07.07.2017
 

Question:

How can I access the FTP server of technical support?



Answer:

You can download data from and upload data to the FTP server.

To access our FTP server, you require a current Windows operating system. Do the following:

Please enter the following address in Windows Explorer (do not use Internet Explorer!):

ftp://nemhotline:ha37jvg8f@ftp.nemetschek.de


1. Downloading data:
You can find our data in the /Download folder.
Right-click the folder(s) or file(s) you want to download and select "Save Target As ...".
Specify where you want to copy the data by selecting a folder on your computer.

If customers agree, we can provide customer-specific data in the /Customerfolder.
For this, you will get separate instructions.


2. Uploading customer data:
If we agree, customers can upload data to the /Upload folder.



Notes:

  • You can upload only files. You cannot upload folders to the server. If you want to upload an entire project, please save this project to a ZIP file first.
  • You can also use Internet browsers to access the FTP server. However, there are some restrictions. Use an FTP client program (for example, FileZilla)to avoid errors. This makes it easier for you to upload and download data. See the following information.
  • Login details for FTP program:
    Address:
    ftp.nemetschek.de
    Login:
    nemhotline
    Password:
    ha37jvg8f
Download PDF  FAQ_EN_Data_on_FTP_server_.pdf
Version:  Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011 / Allplan 2009  | Last modified: 22.01.2020
 

Question:

How can I remove NemSLock completely from a computer?



Answer:

Do the following:

  1. Uninstall Softlock 2006 by clicking Start -> Control Panel -> Programs and Features.

  2. Select "Nemetschek SoftLock 2006" and then click "Uninstall/Change". Select "Remove" -> Next -> Yes.
  3. Extract the "NSLFixer2006.zip" file attached and copy it to any folder on your computer. If your email provider or firewall software has blocked this file, you can also download it from our webdrive. Use this link:

    https://webdrive.allplan.com/index.php/s/4LrjrymoxESzC6p

    The tool "NSLFixer2006.exe" is under Allgemein/Nemslock

    (click on the right hand side next to file size on the three dots and chose &apos;herunterladen&apos;)

  4. Start NSLFixer2006.exe by double-clicking it.
    Important note:
    If you are running Windows Vista or a newer operating system, click the program with the right mouse button and select "Run as administrator". Confirm the following message.
  5. Create the key by clicking "Generate/Enter a key" (1).

  6. Select the line to the right of "Generate/Enter a key" (2), "1F02E74917D3F6E7348C1F02E74917D35E2599A254864A233C549A25ADD2EDFD", for example, and press "Ctrl+C". Paste this key into an email and send it to "support.de@allplan.com".
  7. We will send you another key. Please copy this key to the second line (3). If you need to restart the program, paste the key you created into the first line (see step 3, do not click "Generate/Enter a key" again!). Then click "Validate twin key" (4). After you have done this, you should see the following message: "System cleaned. Reinstall NemSLock".
  8. Update your current Allplan version. Use the temporary license file ("psd" can be found in its file name). You can also find your current temporary licenses at www.connect.allplan.com. Go to "Profile -> License administration".
    Students should use the Allplan Setup program which they can download from Allplan Campus (http://www.allplan-campus.com -> log on -> select "Software" at the top -> download Allplan). Use the trial license provided by Setup.



After this, request a new license by sending a new registration request (Services application -> Utilities -> License -> License Manager). Select the license entry for your seat and click "Request license".
If you work with a license server, reconnect the client with the server.

Download PDF  FAQ_EN_Removing_NemSLock_completely.pdf Download NSLFixer2006_EN.zip
Version:  Allplan 2017  | Last modified: 09.10.2017
 

Information:

This document provides further information on installing Allplan 2017.

Backing up and archiving data:

We strongly recommend that you back up and archive all your data before you upgrade to Allplan 2017.


How to install:


You can find detailed instructions on how to install Allplan 2017 in the following places:

- After you have downloaded Allplan 2017, you can find the install.chm file in the Helpfiles\English folder.
- You can find the install.chm file on the Allplan 2017 DVD in the following folder: <DVD>:\programs\x64\Allplan\Helpfiles\English.

Please read these instructions before you install Allplan 2017.

Some notes on installing Allplan 2017

If you want to switch from Allplan 2014/2015/2016 to Allplan 2017, you can choose between three installation options. We recommend using the second option: first-time installation and copy data from Allplan 2014/2015/2016.

1. First-time installation

This option installs Allplan 2017 to a new folder without affecting any other Allplan installation (2016 or earlier). Setup does transfer neither data nor settings to the new installation.

If you want to transfer data later, you have the following options:

You can uninstall Allplan 2017 and then upgrade from Allplan 2014/2015/2016.
You can integrate the data manually (requires administrative knowledge).

2. First-time installation and copy data from Allplan 2014/2015/2016

This option installs Allplan 2017 to a new folder without affecting any other Allplan installation (2016 or earlier). You can configure the program to automatically copy the office standard (\std), projects (\prj) and user data (\usr) from Allplan 2014/2015/2016 to the new installations folder.
This duplicates the data: you can use all projects, defaults and resources both in Allplan 2016 and in Allplan 2014/2015/2016. This way, you can test the new version without losing your &apos;old&apos; Allplan version.
Bear in mind, though, that you should not mix data from different versions, as merging data later involves considerable time and effort.

2a. Continue with first-time installation and copy data from version

This option is available when you have already installed <Product_Version> and copied the data to a different computer that accesses the same data server. As a result, the data have already been transferred.

3. Upgrade and transfer data from Allplan 2014/2015/2016

This option installs Allplan 2017 to an existing folder, converting Allplan 2014/2015/2016 to Allplan 2017 and transferring all important settings. Afterwards, you can no longer work with Allplan 2014/2015/2016.
This does nor affect earlier Allplan versions (Allplan 2013 or earlier).



Installing on a network:

  • If you work in a network environment (one common central file storage folder), you must upgrade all workstations to Allplan 2017. Therefore, make sure you can upgrade all workstations (deadline for Serviceplus agreement: July 1, 2016) beforeyou start installing.
  • During the upgrade, Allplan 2014/2015/2016 must not be running on any workstation.
  • When installing with Workgroup Manager, make sure all workstations are checked in before you start upgrading.



Converting data:

IBD 2017

IBD 2017 is expected to be released with the Allplan 2017-0-1 Hotfix at the end of July 2016.
https://connect.allplan.com/en/faqid/20160707142752.html


Download PDF  FAQ_EN_Hotletter_2017.pdf
1 - 10 (14)
https://campus.allplan.com/ uses cookies  -  More information