Question:

I cannot activate Allplan. When I enter the Product Key, the "no Internet connection" message appears even though the computer is connected to the Internet. Which ports are required? Are there any settings for the proxy server?


Answer:

License activation accesses the internally used URLs

https://lc.codemeter.com/59885/gateways/getLicenses.php and
https://lc.codemeter.com/59885/gateways/getTicketInformation.php.

Make sure the proxy server does not block these URLs.
Try to activate the license again.

Download PDF  FAQ_EN_License_activation_-_no_Internet_connection_w...
Version:  Allplan 2021 / Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 01.10.2020
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

Internet connection exists on your computer and the settings used for the proxy for the URLs you have set also. You try to activate your license with your product key, but the activation could not be performed. You get the message ' server not found error'. How can the license be activated yet?

Reply:

License activation:

The following description is valid for single user license as also license server licenses.

Try to activate the licenses on the computer/server via the following website online.
This Web site must be launched directly on the computer on which the license should be enabled.


http://lc.codemeter.com/59885/depot/index.php

In the row "Ticket", enter your Product Key and click continue your license will be displayed, click on activate license now.

Note: (only for license server license)
A selection appears asking for the binding of licenses.
Select firm code 6000100 on the right hand side.
'I want my licenses on one computer (CmActLicense). Firm code: 6000100 CmContainer ALLPLAN CM6 (2000)'

Sometimes multiple rows for the same license will be displayed (E.g. license number and a -u behind it) please leave all licenses checked and click on Activate selected licenses now.

The transfer of the license starts now. When activation is finished your license on this page should now appear with status activated.

If the problems with license activation occurred during the installation of ALLPLAN, cancel to exit Setup and restart the installation of ALLPLAN again. Then select in the Setup license configuration use active license now and the installation can continue.

Then open the license setting over services -> utilities-> license settings.
Or license server via License Settings.

Click on the left side on license selection. Now the license is displayed under the computer name.

License return:

This Web site must be launched directly on the computer on which the license should be enabled.


http://lc.codemeter.com/59885/depot/index.php

In the row "Ticket", enter your Product Key and click continue your license will be displayed, click on re-host license now.

Sometimes multiple rows for the same license will be displayed (E.g. license number and a -u behind it) please leave all licenses checked and click on Re-host selected licenses now.

The transfer of the license starts now.

Notes:

  • Sometimes the license is not displayed under license activation, because it has been enabled via the website.
  • If you want to remove the licenses, you must do so via the website again.
Download PDF  FAQ_EN_License_activation_returning_is_still_not_pos...
Version:  Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014  | Last modified: 20.08.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Questions:

Why can’t I see anything in a project or why are elements missing from drawing files?
Why are layers not visible?
Why is it not possible to select a privilege set in layer selection?



Answer:

Probably, you have not yet been assigned any privilege sets or the layers are frozen in the privilege set in question. First, check whether you can select another privilege set.


1. Selecting another privilege set

To do this, select the project in question and open the layer settings(Format -> Select, Set Layers). Go to the “Privilege set in list box” area at the top on the right and check whether you can select another privilege set (for example, ALLPLAN).
By default, all layers have full access rights in the predefined ALLPLAN privilege set.

If there is no privilege set with full access rights, you should assign the privilege sets correctly.
This can only be done by a user with administrator privilegesor, in the case of a project-specific layer structure, by the project owner.

Thus, log on as a user with administrator privileges and do the following:


2. Assigning a privilege set

Select the project with the frozen layers.

Open the layer settings(Format -> Select, Set Layers). Switch to the "Privilege Set" tab and click Define, modify privilege set.

Select the relevant user and assign the privilege set using the arrows.

Click OKto confirm.


3. Adjusting layers’ access rights in the privilege set

Finally, check the access rights of the layers in the privilege set assigned.
Go to the "Privilege set in list box" area at the top on the right and select the relevant privilege set (for example, ALLPLAN).

Check the area on the left to see whether there are frozen layers (gray or white). To change this, select these layers or simply select all layers using CTRL+A. Then click the Full access right (modifiable)icon in the “Change rights” area.
Click OKto confirm.

The next time you open this project, you can select this privilege set in the layer settings. You can then see all layers and set them to modifiable.

Do the same with print sets.


Alternative:

Since version 2006, the administrator has been able to select Show all users all print sets and privilege setsin the “Administrator options” group on the “Privilege Set” tab (“Design group” in version 2006). Thus, you do not need to assign new users to privilege sets. This option applies to all projects.

However, as soon as a user has been given a privilege set or print set, this option no longer applies to this user.



Note:

As a project can have its own layer structure, it is essential that you check the privilege set in the correct project.
To find out whether a project has its own layer structure, click
File -> New Project, Open Project-> right-click the relevant project -> Properties. Check whether the path settings for Layerstructuresare set to Officeor Project.

Download PDF  FAQ_EN_Enabling_privilege_set_for_user.pdf
Version:  Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 14.02.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

Allplan starts as a viewer. What can I do?



Answer:

Do the following:

1. The Allplan license folder contains the servcfg.nse file.

Open this folder:
Services application -> Service -> Windows Explorer -> General program data (ETC, LIC) -> License.

Delete the servcfg.nse file from this folder.

2. Install the new, appropriate license, which you can find in the attached file. Save the license to a folder on your computer and install it as follows:
Services application -> Utilities -> License -> Install HARDLOCK License

3. Check that the light indicator of the connected USB dongle (blue or white stick) is on all the time. To test it, you can connect the dongle to a different port.

4. Install the current hardlock driver if the light indicator is off.
You can find detailed instructions here:

https://connect.allplan.com/en/faqid/20131028125253.html

5. Select the Services application -> Utilities -> License -> License settings -> Licenses.
Check if "Allplan FT" is displayed in the white window on the left. If this is so, Allplan has accepted the dongle.

If this is not so, send the logmes.nse file, info.001 file and the new servcfg.nse file (license folder) to support.de@allplan.com


Download PDF  FAQ_EN_First_steps_to_solving_hardlock_license_probl...
Version:  Allplan 2013 / Allplan 2012 / Allplan 2011 / Allplan 2009  | Last modified: 30.11.2017
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How can I output a test plot with different data types used in Allplan?



Solution:

Allplan comes with drawing files containing test data that can be used for this purpose.

If necessary, create a new project and copy the drawing files with the test data to this new project.

Open ProjectPilot: Allplan -> File -> ProjectPilot - Admin.

Set the external path to the '..\New\Testplot' folder, which is a subfolder of the local Allplan program folder.
Click 'External path' with the right mouse button and, on the shortcut menu, choose 'Select external path'.
Select the '..\New\Testplot' folder, which is a subfolder of the local Allplan program folder: c:\Programs\Nemetschek\Allplan\New\Testplot, for example.

The following layouts and drawing files are available:

  • Layout 1 - Test Plot Allplan Testbild / Allplan Test Layout
  • Layout 2 - Test Plot Muster & Schaffur / Patterns & Hatching
  • Layout 3 - Test Plot Allplan Testbild / Allplan Test Layout
  • Drawing file 25 - Füllflächen + Stifte / Fills + Pens
  • Drawing file 26 - Muster / Patterns (Version 2006 and later)
  • Drawing file 27 - Schraffuren / Hatching (Version 2006 and later)
  • Drawing file 100 - Allplan Test Drawing File (Version 2008 and later)


Copy these layouts and drawing files to the new project.
Select the relevant drawing files with the right mouse button and choose 'Copy to ...' on the shortcut menu.
Select the new project.

If necessary, create a layout, place the drawing files in this layout, specify an output device and and print the layout.

Note:

Make the following settings to ensure that the data is output correctly:

  • Select "white" for the background color.
  • Turn off "Color stands for pen" in "Show/Hide".
  • Turn off "Surface elements in background of each document" on the "Selection" tab of "Plot Layouts".
  • Use Windows drivers for printing.
  • For HP plotters, select the "Avoid out of memory condition" or "Output as a bitmap" option in the plotter properties.
  • For optimum color output with sRGB values, apply the settings described in the FAQ entitled Color adjustment - Windows drivers and Nemetschek vector drivers.
    https://connect.allplan.com/en/faqid/0001a106.html



Notes:

Colors in printouts can vary depending on several factors such as

  • Output device used
  • Paper used
  • Ink used
  • Driver type used (Windows or Nemetschek drivers)

In particular, colors can differ regarding

  • Color display
  • Brightness


Colors in printouts can even vary if you use the same output device but different Windows drivers.
On-screen display can be influenced by various factors such as different settings for contrast and color temperature.

As the possible settings are so widespread, you can see that it is essential to print out test data in advance.

Download PDF  FAQ_EN_Printing_test_plots.pdf
1 - 5 (5)
  • 1
https://campus.allplan.com/ uses cookies  -  More information

Accept