How can I work from home with Allplan without a direct LAN connection to a common file storage folder?



Answer:

1. Working from home with direct access to the central data


If you want to work together on projects, you can use Allplan Share, Allplan’s cloud solution, to work with Allplan without a LAN connection to the central file storage folder. This is only possible if Allplan is installed as a standalone version on a computer without access to a central file storage folder; otherwise, Allplan does not start. If the computer is part of a workgroup installation, the computer must be checked out and used outside the LAN (like a standalone workstation). Data access is via cloud services.
This is only possible if you use Allplan Share for cloud storage.

Working with Allplan Share is just as simple as working at a standalone workstation. You and several other users can access and edit a project at the same time.

To get more information on Allplan Share, use the following link or contact your sales partner:

https://www.allplan.com/de/add-ons/allplan-share/


You can also find further information on Allplan Connect; use the following link:


https://connect.allplan.com/de/forum/themen/topic/topics/cad-allgemein-1/moderierter-sammelbeitrag-zugriff-auf-allplan-projekte-aus-dem-homeoffice-via-allplan-share.html


Note:

VPN is not useful for common project storage.
Allplan exchanges many files with the data server. VPN uses advanced encryption, which considerably slows down data transfer.
A connection via VPN is not approved for Allplan because data might get damaged even if the connection is interrupted only briefly. In addition, working over the internet is extremely slow if the internet connection is not fast enough (at least 100 Mbit).
Allplan does not support a VPN connection with IPv6; Allplan detects only IPv4.
Make sure that the VPN connection does not switch to sleep mode.

Please note that we cannot provide support for this constellation.



2. Working from home without access to the central file storage (working locally):



2.1 Allplan with workgroup manager:

If workgroup manager is included in your license, you can check out a computer or laptop with projects from the workgroup environment. You can then work from home without access to the server. The projects on the computer or laptop that is checked out are locked for the CAD users on the network. These users see the comment you entered when you checked out the computer.

You can find instructions at

https://connect.allplan.com/en/faqid/20160923105251.html

When you use a license server, you can get the license via a VPN connection or borrow the license beforehand:

https://connect.allplan.com/en/faqid/20180109095437.html
https://connect.allplan.com/en/faqid/20160523165423.html




2.2 Allplan without workgroup manager:

Using the office computer
If you have neither workgroup manager nor network access, you must uninstall Allplan and install it again by specifying the local paths. To work with a project, you must back it up and then import it to the local installation.

Using a new (private) computer
If you want to use a new computer to work from home, you must return the license at the office computer and then use this license to install Allplan on the new computer.


We recommend that you do not mix data from the office computer and the private computer. Merging data later involves considerable time and effort.

Use the following link to find out how to transfer projects:

https://connect.allplan.com/en/faqid/20180507154505.html

Download PDF  FAQ_EN_Working_with_Allplan_from_home.pdf
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014  | Last modified: 31.10.2019
Not voted yet. Be the first to vote this FAQ as helpful!

Question:

How can I check out a laptop and resume work as a normal CAD user with my usual settings and privileges?



Answer:

Log on as the Allplan administrator to the laptop.



Step 1: add computer to Workgroup Manager
The laptop needs to be integrated in the workgroup so that it can be used for data storage (data server). Do the following:

Create data folders:
Create a folder - 'Nemdata', for example - on the laptop and share it (full control).
Create the 'Allplan' subfolder in this folder. Create two subfolders - 'usr' and 'prj' - in the Allplan folder.
In this example: '...\Nemdata\Allplan\prj' and '...\Nemdata\Allplan\usr'

Add computer:
Start the Services application -> Workgroup Manager -> Administer projects and computer
In the "Remote projects" area on the left, click on Workgroup Server with the right mouse button and select Add computer on the shortcut menu.
Find the computer you want to add, open the local share and select the folder with the 'usr' and 'prj' subfolders (in this example: 'COMPUTERNAME\Nemdata\Allplan'). Confirm by clicking OK.

Install the "Microsoft Loopback Adapter" driver.
This driver is necessary so that network services are always running on the laptop.
Please refer to Allplan Connect for a detailed description: https://connect.allplan.com/en/faqid/000162ae.html


Step 2: move user folder (optional)
Allplan 2013 and later: the user will be move automatically
(Start the Services application -> Workgroup Manager -> Administer users
Click with the right mouse button on selected user who is going to work on the laptop outside the network environment.
Select Properties
In the field user folder select the laptop
Repeat step 2 if several users are to work with the laptop.

Note:
If user folders have been moved to the laptop and this laptop has been checked out, the user in question can only work with the laptop and not in the office.)


Step 3: define project owner
A user can only move a project if he/she is the owner of this project.
The ownership of a project can only be changed by an Allplan administrator (or the owner of the project).
Allplan -> File -> ProjectPilot - Admin... ->
Click the relevant project with the right mouse button and select Properties on the shortcut menu.
Now you can define the owner.


Step 4: move projects
Log on as the user who wants to check out the laptop.
Start the Services application -> Workgroup Manager -> Administer projects and computer
In the "Remote projects" area on the left, select the computer with the projects you want to move.
Drag the projects one after the other to the laptop to be checked out.


Step 5: check out laptop
Start the Services application -> Workgroup Manager -> Administer projects and computer.
Click on your laptop and click on Check out at bottom right.
Confirm the message indicating that there are still user folders on the computer to be checked out.
Enter a comment and click OK. This comment is displayed if users in the office try to access a project on the computer checked out.
Specify which parts of the office standard are to be copied to the laptop and click OK to confirm.



Conclusion:

Now you can remove the laptop from the network and edit your projects when you are out of the office. To make sure that the projects are not changed in the office in the meantime, the projects that are on the computer checked out are locked for the CAD users on the network. These users see the comment you entered when you checked out the computer.


Note:

  • Only the local computer can be checked out (you cannot check out a different computer in the network).
  • Projects on this computer must neither be locked nor in use.


Download PDF  FAQ_EN_Workgroup_manager_checking_out_computer_and_w...
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018  | Last modified: 30.12.2019
4 user(s) found this FAQ helpful

Question:

  • Why can't I create elements?
  • Why can't I move a drawing?
  • Why are elements not created correctly?
  • Why does the program crash when I import a DXF file from the land registry office?
  • Why is the outline of a circumscribed area not detected correctly?
  • Why can't I calculate shadows?
  • Why are elements not displayed correctly in animation?
  • Why are parts of dimension text missing?
  • Why do the contents of the screen suddenly rotate?
  • Why can't I get a preview when I move or copy elements?
  • Why are areas not calculated correctly?




Finding the reason for these problems:

Check whether an offset is set in the project settings (File -> New Project, Open Project-> select the project and open the shortcut menu -> Properties; Allplan 2009 and earlier: Tools -> Options ->Advanced Draft -> Settings). If there are offset coordinates, clear the check box.

Select Tools -> Measure(->)Coordinates.
Click in the middle of the drawing in plan view.
If there are very large values (for example, x/y/z greater than 5000 m), you have found the reason for these problems.

The system has problems calculating and displaying data with very large coordinates. The more data you have with very large coordinates, the greater this effect.



Solution:

  • Click Tools -> Options... -> Desktop environment -> Generaland select Optimize working with large coordinates(Allplan 2009 and earlier: Tools -> Options -> Global Options -> Miscellaneous tab -> Optimize working with large coordinates). After this you must restart Allplan. Otherwise, this setting has no effect.

This is a user setting you must define separately for each user.

  • Usually, the best solution is to move the data towards the Allplan origin. Use the "Move" tool. When Allplan prompts you to specify the target point ("To point"), select Global point in the dialog line. You can find detailed information in the help for Allplan. Look for the Global pointtopic.



Note:

If the data are still not displayed correctly, do the following:
Exit Allplan -> Services application-> Service -> Hotline Tools-> cleanup -> start Allplan.

Download PDF  FAQ_EN_Large_coordinates.pdf
Version:  Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 07.08.2019
10 user(s) found this FAQ helpful

Question:

After I updated Windows (8 to 8.1; 8.1 to 10), Allplan only starts as a viewer. What can I do?


Answer:

Windows update corrupts Nemetschek Softlock License Manager.
To fix Allplan, do the following:

You need the latest installation package for your version.
You can download this package from our webdrive

https://webdrive.allplan.com/s/4LrjrymoxESzC6p

You can find the installation packages in the following path:
Allplan/"Version"/Installationspaket/

Copy the zip file to the local computer and unzip the file.
Start the installation and run an update use our temporary license file.

You can download the temporary license from Allplan Connect:
https://connect.allplan.com


After the installation, you can open License Manager again (Services application -> Utilities -> License -> License Manager). Next, install the temporary license (*_psd.nslock): "Install - Install license"
Note: the status of the temporary license is set to "Expired".

Next, create a new registration request.
To generate a registration request, do the following:

Open License Manager (Services application -> Utilities -> License -> License Manager). Select the license entry for your seat and click "Request license".
Follow the instructions displayed on screen. Complete the form. Do not forget to enter your email address.

Check that the Client ID and CD Key are correct.

Send the registration request to: register@nemetschek.de.

Download PDF  FAQ_EN_Fixing_NemSLock_after_Windows_update.pdf ...
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 02.10.2019
4 user(s) found this FAQ helpful

Question:

I purchased the license server. How can I install and configure the license server?



Answer:

Allplan is using since version 2016 a new protection system. Licensing is based on CodeMeter by Wibu Systems AG since then. You can no longer use NemSLock Server with Allplan 2016 and higher.

Allplan requires a Product Key. Using this key, you can activate your license online. The Product Key is a unique, 26-digit character string. You can use it to activate a license for Allplan.
You can find your Product Key in Allplan Connect. Go to http://connect.allplan.com/license
Note: The license is downwards compatible til version Allplan 2016-1-4 even if a higher version is displayed.



To install the license server, download the software for the license server from Allplan Connect
or from our FTP server:
ftp://nemhotline:ha37jvg8f@ftp.nemetschek.de/download/Allplan/Lizenzserver/2017/DoWn-License_Server_Setup.zip

The Wibu license server is part of the CodeMeter driver, which is installed along with Allplan. If you have already installed Allplan on the license server, you do not have to install additional software. But you can also install the license server separately; you do not have to install Allplan.
In any case, install and activate the license server before you install Allplan on the clients.

You can activate a license in online mode only if you have ...

  • Internet access
  • a Product Key
  • a license server license; you cannot use other licenses with the license server.




Installing the license server

  • You must install the license server on a 64-bit Windows system.
  • Start License Server Setup on the computer you want to use as the license server.
  • Click Install.
  • Start the license server by starting the License Settings program. Go to the License activation area, enter your Product Key and click Activate license.
  • If you have more licenses for the license server, enter the respective Product Keys and activate the licenses.
  • Afterwards, start CodeMeter Control Center.

To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen: enter Codemeter and press ENTER. A dialog box opens. Click WebAdmin at bottom right.

Or
Enter Localhost:22350in the address bar of your browser.

  • Select Configuration -> Server -> Access server in the Network server area and click Activate.
  • Click Apply.



Configuring the license server (optional)

You can use the CodeMeter WebAdmin application to administer the license server.
To start and stop the license server service, you can use CodeMeter Control Center.

  • CodeMeter Control Center -> Action -> Start or Stop CodeMeter Service


Access control
By default, all users on the LAN, who have installed the CodeMeter driver, can use a license from the license server.

  • Basic access control: you can enter a list of client computer names or IP addresses that are allowed to access the license server.
  • Advanced access control: you can specify global access rules (for all licenses) to control access to the licenses.


License tracking
To activate license tracking, you have to set the HKEY_LOCAL_MACHINE\SOFTWARE\WIBU-SYSTEMS\CodeMeter\Server\CurrentVersion\LogLicenseTracking registry entry to 1 and restart CodeMeter Service.

After having activated this key, you can use CodeMeter WebAdmin to create a report showing details about the licenses used over a specific period of time. To do this, open CodeMeter WebAdmin and go to the 'Server' - 'License Tracking' page. Select the period of time and the license for which you want to generate a report. Then click 'Create report'. If you click a single bar, you will get detailed analyses per day or per hour.

CodeMeter WebAdmin saves the reports to C:\ProgramData\CodeMeter\Logs.



Installing and configuring clients

Note for Version 2016: Install at least Allplan 2016-1-4 on the clients.

The license server license will be detected automatically on the network.
Install Allplan on the clients. When you are prompted to select the license file, click Use active license. Follow the installation instructions.

  • You do not need to activatethe clients.


Allplan automatically finds the license server on the local network. If you have not selected a license, Allplan automatically selects the first available license.

After having installed Allplan on the clients, you can use the 'License Settings' dialog boxto configure license selection.
Services application -> Utilities -> License settings

Areas:

  • License activation: this area is not relevant to clients taking their license from the license server.
  • License selection: use this section if you get the license from a license server or if you have several licenses and you want to select the preferred license.
  • Start as a viewer: click this button if you want to start Allplan as a viewer.



License selection

You can see the names of the available licenses with their seat numbers.
The 'Available' column indicates how many licenses are still available. Click the dropdown arrow to see a list of users currently working with a license.

Priority:
Select the check box in front of a license to select this license as a favorite. You can mark as many licenses as you want. Allplan will then prefer these licenses. Click to select one ore more licenses Allplan is not to use. If you do not select any license or if you have selected several favorites, Allplan will automatically use the first free license it finds.

Find license server automatically:
When you select this option, Allplan automatically detects a license server on the LAN. In some cases, such as VPN connections, Allplan may not be able to detect a server automatically. In this case, you can enter the server manually (see Additional server name).
Note: Only the Windows administrator can change this option.

Additional server name:
If 'Find license server automatically' is not active or Allplan has not automatically found a license server, you can manually enter the name or the IP address of the server. If 'Find license server automatically' is active, you can enter an additional server. After having entered the server name, click 'Update' to see the licenses of the license server. Use semicolons to separate several server names.


Note:

You can find detailed information on the license server in the License Settings help (F1 key).

Allplan communicates with the license server via TCP/IP. By default, communication is via Port 22350 unless you change the port in CodeMeter WebAdmin.

If a firewall is active on your computer, you must enable port 22350 for TCP and UDP. If the firewall filters in an application-specific manner, you have to enable the CodeMeter.exe license server service. You can find this service in the %Program Files (x86)%\CodeMeter\Runtime\bin Windows folder. Define the CodeMeter.exe service as an exception in the firewall. Some anti-virus programs also include firewall functions. If you are not sure, contact the manufacturer of the anti-virus program.

Download PDF  FAQ_EN_Installing_and_configuring_the_license_server...
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013  | Last modified: 25.11.2019
3 user(s) found this FAQ helpful

Question:

What are the differences between a major release, a service release and a hotfix?



Answer:

Major release

The major release is the first release of a new version.
You can download it from the homepage.

Download:
www.connect.allplan.com -> Download -> Software packages
(requires login details for Allplan Connect)

Name (example):
Allplan 2015


Service release

A service release is a collection of improvements to the program, including all the service releases and hotfixes that have been released until now. In addition to improvements, it may also include new features.
You can also use a service release for a new installation or an upgrade (from a previous version).
You can download it from the homepage.
New customers get it as a DVD. Serviceplus customers get it on request.
In addition, they automatically get information about service releases.

Download:
www.connect.allplan.com -> Download -> Software packages
(requires login details for Allplan Connect)

Name (example):
Allplan 2015-1


Hotfix

A hotfix is an improvement to the program that will automatically be installed by Allplan Update.
The basis for the installation is a specific major release or service release.
Hotfixes are installed one after the other in the correct order, that is to say, first Hotfix 2015-1-1 and then Hotfix 2015-1-2.

Allplan automatically installs available hotfixes when it starts.

You can find more information on hotfixes in the following FAQ:
https://connect.allplan.com/en/faqid/20101203111503.html




Tip:

Install program updates as soon as they are available.

Download PDF  FAQ_EN_Program_updates.pdf
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 25.11.2019
2 user(s) found this FAQ helpful

Question:

How can I import data from an earlier version?



Answer:

You can import data from the last three Allplan versions.
Consequently, the following import operations are possible:

Target version <- import possible from version

2017 <- 2014
2016 <- 2013
2015 <- 2012
2014 <- 2011
2013 <- 2009
2012 <- 2008
2011 <- 2006
2009 <- 2005
2008 <- 2004
2006 <- 2003
2005 <- 17
2004 <- 16

We cannot guarantee that data created in older versions can be imported and edited. The conversion of older data may be incomplete, which may affect intelligent components in particular.


1. Archived data from an earlier version (not older than three previous versions):

There are two ways to convert the data to the current version:

  • Import the project backups created and archived using the
    Services application -> Data Backup -> Import -> Projects.
    After importing the projects, convert them by opening each project once.
  • Import the backups archived using the
    Services application -> File -> Restore documents of any version to '...\Extern'.
    The data are written to the external path.
    You can now process the converted data in ProjectPilot.



2. Archived data from an older Allplan version (older than three previous versions):

  • See whether you can use the approach described in step 1 to import the old projects.
  • If available, it is a good idea to install an old Allplan version. Import the backups created and archived into this old version and convert the projects using the Services application. If you have imported a complete project backup, convert the data by opening each project once. When finished, repeat this process with a newer version (up to three versions later) until the data are up-to-date.
  • If an old Allplan version is not available, you can also have the data converted by Allplan. Please note that this service is not free of charge. Please contact Technical Support -> support.de@allplan.com.




Notes:

  • You can convert the data of all projects at once. Read the following FAQ in Allplan Connect: https://connect.allplan.com/en/faqid/20090408124904.html
  • If enough hard disk space is available, you are advised to keep and maintain the projects so that Allplan automatically converts them to the current version whenever you upgrade.
  • If there are project-specific smart symbol catalogs, you should open the smart symbol catalog once to convert the data.
Download PDF  FAQ_EN_Transferring_data_from_old_Allplan_versions_....
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 24.10.2019
3 user(s) found this FAQ helpful

Question:

Allplan does not start. When you open license selection in the license settings, you can see the following message: "Cannot find a license for running Allplan." Sometimes you might also see one of the following error messages: "This license is no longer available", "CmActLicense runtime system is not installed!" or "NemAll_DataResource20.dll: Start Error 102". Allplan no longer starts after these messages. How to solve this problem?

Answer:

Check the following points:

On the client:

Open the license settings: Services application -> Utilities -> License settings

1. Has the license been blocked on the client?
Check the 'License selection' area to find out whether your license has been blocked. This is indicated by the symbol. If the license is blocked, Allplan cannot use it.
Click this symbol to unblock the license again. If you want, you can select the check box in front of the license to select it as a favorite. Allplan will then prefer this license.
If you do not select any license or if you have selected several favorites, Allplan will automatically use the first free license it finds.


2. Has the server been found?

Select the 'Find license server automatically' option. You should now see the license provided by the server.

Note: In some cases, such as VPN connections, Allplan may not be able to detect a server automatically. In this case, you can enter the server manually.


3. Is the local Windows service, which is used by licensing, running correctly?

If communication with the local Wibu service is blocked, Allplan cannot find the license anymore. This is often caused by the virus scanner.
So you need to exclude the "Codemeter" folder from virus scans. You can find this folder in the following path: C:\Program files (X86)\Codemeter or C:\Programme (x86)\Codemeter

Then restart the service:

Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen and enter Codemeter.

CodeMeter Control Center -> Process -> Start CodeMeter Service
If the service is running, stop it and restart it.


On the license server:

4. Is the 'Start network server' option active?

Start CodeMeter Control Center on the server.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. As an alternative, open Search by clicking the Search button on the Start screen, enter Codemeter and press ENTER. A dialog box opens. Click WebAdmin at bottom right.

Or
Enter Localhost:22350in the address bar of your browser.

  • Select Settings -> Server -> Access serverin the Network serverarea and click Activate.


Update the license settings on the client. To do this, click Updateor open the dialog box with the license settings again. You should now see the license on the client.


5. Restart the license server service on the server

To start and stop the license server service, you can use CodeMeter Control Center.

  • CodeMeter Control Center -> Action -> Stop CodeMeter Service
  • CodeMeter Control Center -> Action -> Start CodeMeter Service


Update the license settings on the client. To do this, open the dialog box with the license settings again. You should now see the license on the client.


6. Is the virus scanner blocking the Windows service, which is used by licensing, at the server?

If communication with the Wibu service is blocked, Allplan cannot find the license anymore. This is often caused by the virus scanner.
So you need to exclude the "Codemeter" folder from virus scans.
You can find this folder in the following path: C:\Program files (X86)\Codemeter or C:\Programme (x86)\Codemeter
In addition, exclude the C:\Program Files\Allplan GmbHfolder.

Then restart the license server service:
If the service is running, stop it and restart it.


7. Check the firewall

Allplan communicates with the license server via TCP/IP. By default, communication is via port 22350 unless you change the port in CodeMeter WebAdmin. So you need to configure the firewall accordingly.

If a firewall is active on your computer, you must enable port 22350 for TCP and UDP. If the firewall filters in an application-specific manner, you have to enable the CodeMeter.exe license server service. You can find this service in the %Program Files (x86)%\CodeMeter\Runtime\bin Windows folder. Define the CodeMeter.exe service as an exception in the firewall. Some anti-virus programs also include firewall functions. If you are not sure, contact the manufacturer of the anti-virus program.

Download PDF  FAQ_EN_License_server_-_cannot_find_a_license_.pdf ...
Version:  Allplan 2020 / Allplan 2019 / Allplan 2018 / Allplan 2017 / Allplan 2016  | Last modified: 23.09.2019
7 user(s) found this FAQ helpful

Question:

My computer does not have Internet access, but I would like to activate the license with the Product Key. What can I do?


Information:

The easiest way to activate and return Allplan licenses is to do this online. In other words, the computer has Internet access. However, you can also activate Allplan on a computer without Internet access (offline licensing). Offline licensing is particularly useful if some Allplan computers in your office do not have Internet access and do not use a license server either.

If the computer without Internet access and the computer with Internet access are neither close to each other (for example, the computer in the office hasInternet access, but the computer at home does not haveInternet access) nor connected with each other (for example, using LAN), offline activation is not very suitable, as you have to access both the computer with Internet access and the computer without Internet access.

Requirements for activating a license offline:

  • You have a valid Product Key.
  • You have installed Allplan on the computer without Internet access (for example, as a viewer).
  • You have another computer with Internet access.


Important: Activating a license offline involves two steps. In addition, you need to upload a receipt file so that you can return the license offline later.

There are the following basic steps:

  • Creating and uploading the license request file
  • Downloading and importing the license update file
  • Creating and uploading the receipt file


The online computer uses the following web page:
http://lc.codemeter.com/59885/depot/index.php


Note:

As both the license file and the receipt file are saved with the name of the container number by default, it may happen that you mix up these two files. Therefore we strongly recommend that you use meaningful names for the files. For example, the name could include the name of the computer and the Product Key or the words “license” and “receipt”.
This is particularly important if you want to activate several computers offline.


Answer:

A: Activating licenses offline

To activate licenses, use CodeMeter Control Center.

Start CodeMeter Control Center.
To do this, use the Windows start menu and select CodeMeter -> CodeMeter Control Center. An an alternative, go to the Windows search box and type Codemeter.

You can find the container numbers in the ‘License’ area.
If you have a stand-alone license, the name of this container is Allplan GmbH and its number is 327XXXXXXX.

Select this container and click Activatelicense on the right. Select
Create license request. Create a *.WibuCmRaC file for your container.

Take this file to a computer that is online.
Go to the following web page:
http://lc.codemeter.com/59885/depot/index.php

Enter your Product Keyin the “Ticket” line and click Next. You can now see your license.
Click Activate license.

You can see your license and all available updates, which should be selected. Click Offline License Transferat the bottom on the right.

You can now upload the *.WibuCmRaC file (Browse....) by clicking Upload license request now. This creates your license, which you can download by clicking Download license update file now. Install this license on your computer.

To do this, go to CodeMeter Control Center and click File-> Importlicense.


You can see the activated license in the Services application -> Utilities -> License settingsand you can now use this license for Allplan.


Finally, upload the receipt file.
To do this, open CodeMeter Control Centeragain and select the new Allplan GmbH license with the number 128-XXXXXXX.

Then click License update -> Next -> Create receipt.
Create the receipt file for this container.
Upload this receipt file using the web page.

Take this file to the computer that is online. Click Nexton the web page.
If you have already closed the web page, use the link given above and enter your Product Key once again. Then select Continue with license transfer.
Select the receipt file and click Upload receipt now.
Click OKto confirm. This completes license activation.




B: Returning licenses offline

You can return licenses in the same way:
Start CodeMeter Control Center and select the container with the license (Allplan GmbH with the number 128-XXXXXXX). Then click License update -> Next -> Create license request.
Here, too, create a *.WibuCmRaC file for your container.

Take this file to a computer that is online.
Here, too, go to the following web page:
http://lc.codemeter.com/59885/depot/index.php

Enter your Product Keyin the “Ticket” line and click Next. You can now see your license.
Click Move license.
Click Offline License Transferat the bottom on the right.
You can now upload the *.WibuCmRaC file (Browse....) by clicking Upload request now.
Then click Download license update file now. Download the file and import it. To do this, go to CodeMeter Control Centerand click File -> Importlicense.

Then create a receipt by clicking License update -> Next -> Create receipt.
Upload this receipt file using the web page.
To do this, click Nexton the web page.
If you have already closed the web page, use the link given above and enter your Product Key once again. Then select Continue with license transfer.
Select the receipt file and click Upload receipt now.
Click OKto confirm. This completes license activation.

The license is now available again and can be used on another computer.

Download PDF  FAQ_EN_Activating_license_offline_(without_Internet_...
Version:  Allplan 2018 / Allplan 2017 / Allplan 2016 / Allplan 2015 / Allplan 2014 / Allplan 2013 / Allplan 2012 / Allplan 2011  | Last modified: 15.11.2017
1 user(s) found this FAQ helpful

Question:

How can I update cross-section catalogs or install country-specific cross-section catalogs in Allplan 2011 and later?



Answer:

To install and save cross-section catalogs in Allplan 2011 and later, select Tools -> Defaults -> Cross-Section Catalogs. A dialog box opens. You can find a folder symbol and a disk symbol at bottom left.

To install cross-section catalogs, use the folder symbol. Another dialog opens, where you can select the cross-section catalog file you want to install. Select the file to be installed and click "Open" to confirm. This installs the corresponding cross-section catalog, which you can now use in Allplan.
To install country-specific cross-section catalogs, select the "Ing" folder, which was created when you installed Allplan. You can find it in the Allplan installation path (e.g., c:\Nemetschek\Allplan 201x\New\Ing - more information on the Allplan installation path is provided below in the "Notes" section).
This folder includes the country-specify cross-section catalog files.

To save a custom cross-section catalog, use the disk symbol. Another dialog opens, where you can select any folder to save the cross-section catalogs currently used in Allplan.



Note:

To update cross-section catalogs, you may need administrator privileges. If necessary, log on as an administrator before you start the update.

To use the cross-section catalogs for a specific project only, set the path settings for the cross-section catalogs of this project to project before you install the cross-section catalogs. In Allplan, open the "File" menu and select "Open Project..." Click the corresponding project with the right mouse button. Select "Properties". A dialog box opens. In the "Path settings" area, set the "Bar and mesh cross-section catalogs" to "Project".

To determine the path where Allplan is installed, use the Services application and select Service -> Hotline Tools-> showcfg. The Services application window shows the path of the Allplan installation folder.

The following abbreviations are used for the country-specific cross-section catalogs in the file names (axyzqusr.txt):
aut Austria
bel Belgium
bra Brazil
bul Bulgaria
deu Germany
eng England
fra France
hol Holland
hrv Croatia
ita Italy
kor Korea
pol Poland
rum Romania
rus Russia
slk Slovakia
svn Slovenia
swi Switzerland
tch Czech Republic
ung Hungary
usa USA

Download PDF  FAQ_EN_Updating_cross-section_catalogs_(Allplan_2011...
1 - 10 (54)
| A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z |
https://campus.allplan.com/ uses cookies  -  More information

Accept